Benutzeranleitung / Produktwartung USAC-40 des Produzenten Continental
Zur Seite of 12
Technical Guide Form UTG-0204 Continental Chillers LLC UniPac ™ Single Phase Air Cooled Chillers Water Cooled Chillers Split System Chillers 3 through 60 HP Phone: 317-337-9813 Fax: 317-337-9816 www.
Phone: 317-337-9813 www.continentalchil lers. com Fax: 317-337-9816 Continental Single Phas e Chillers UniPac™ Introducing UniPac™ Chiller Systems All over the world, Continental has successfully developed and marketed va rious packaged and split chillers to serve many needs.
Phone: 317-337-9813 www.continentalchil lers. com Fax: 317-337-9816 Continental Single Phas e Chillers UniPac™ Standard Unit Specifications of UniPac™ Single Phase Chillers General Description Con.
Phone: 317-337-9813 www.continentalchil lers. com Fax: 317-337-9816 Continental Single Phas e Chillers UniPac™ UniPac™ Options and Selection Procedures 1.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ Single Phase Air Cooled Ratings Models USAC-3 through USAC-20 3 through 20 Tons Ambient Air Temperature °F 85 95 105 115 120 LCWT °F Model USAC TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM 3 2.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ Single Phase Air Cooled Ratings Models USAC-25 through USAC-60 25 through 60 Tons Ambient Air Temperature °F 85 95 105 115 120 LCWT °F Model USAC TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM 25 21.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ Single Phase Water Cooled Ratings Models USWC-3 through USWC-60 3 through 60 tons Condenser Leaving Water Temperature, °F 85 95 100 LCWT °F Model USWC TR kW Cooler GPM Cond GPM TR kW Cooler GPM Cond GPM TR kW Cooler GPM Cond GPM 3 3.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ USAC Physical Data USAC-3, 4, 5, 8 USAC-10, 12, 15, 20 USAC-25, 30 USAC-40, 50, 60 Dimensions Water Connections Model USAC L” W” H” Weight, lbs.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ USWC Physical Data USWC-3, 5, 10 USWC-15, 20 USWC-25, 30 Dimensions Water Connections, Inlet”/Outlet” Model USWC L” W” H” Weight, lbs.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chillers UniPac™ Electrical Data USAC Packaged Air Cooled Chillers Total Unit Compressor Motor Da ta Condenser Fan Motor Data Standard Unit Optional Low Ambient Unit Single Phase/Single Speed Motor Single Phase/Speed Control Model MCA Max Fuse Rec.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chillers UniPac™ Installation and Application Data General Continental UniPac™ Air Co oled Packaged Chillers models USAC are designed for outdoor installat ions and nor mal exposure to s ummer and winter condit ions.
Continental Single Phase Chillers UniPac™ UniPac™Guide Spec Furnish and install where indicated on plans Qty______ Continental UniPac™ model (USAC, USWC) ________ _ packaged liquid chiller(s).
Ein wichtiger Punkt beim Kauf des Geräts Continental USAC-40 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Continental USAC-40 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Continental USAC-40 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Continental USAC-40 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Continental USAC-40 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Continental USAC-40 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Continental USAC-40 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Continental USAC-40. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Continental USAC-40 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.