INTELLIGENT LABEL SENSORS OPERA TIONS MANU AL CS2000 & CS2000-QD C S 2 0 0 0 & C S 2 0 0 0 - Q D CS2000 & CS2000-QD CONTROL TECHNOLOGIES 2617 Fremontia Drive San Bernardino, CA 92404 Phone: 877-880-5389 F ax: 877-880-5537 www .
Table of Contents General Information Features Diagram CS2000 Quick Start CS2000-QD Quick Start Installation Mounting CS2000 Wiring CS2000-QD Wiring Operation Label Pla.
- 1 - General Information Features: • 10 to 30 VDC input - reverse polarity protected • Fast RISC microprocessor controlled • Easy one touch setup - label sensitivity easily adjusted, t.
- 2 - General Information Yellow LED: Indicates label backing (web) Push-button Red LED: Indicates output state Green LED: Indicates label + label backing Optional 6" Quick Disconnect 4 Pin Male Cable/Connector #8-32 Mounting Holes EASY SETUP WEB OUT LABEL 1.
- 3 - General Information CS2000 Quick Start: 1. Connect red wire to supply voltage 2. Connect black wire to supply common 3. For NPN Output - connect orange wire to black wire For PNP Output - connect orange wire to red wire 4. Connect white wire to your controller - refer to page 6 for wiring diagrams 5.
- 4 - General Information CS2000-QD Quick Start: 1. Plug the CS2000-QD's male connector into a suitable 4 pin female connector 2. Connect brown wire to supply voltage 3. Connect blue wire to supply common 4. For NPN Output - connect black wire to blue wire For PNP Output - connect black wire to brown wire 5.
- 5 - Installation Mounting: The CS2000 comes with 8 mounting holes allowing for many different mounting options. The holes are tapped for #8-32 screws and are 0.31" deep. We suggest using #8-32 x 3/8" stainless steel screws. Some different options are shown below.
- 6 - Installation CS2000 Wiring: The CS2000 comes with an 8' - 4 conductor cable. Refer below for wire designations. RED = 10-30 VDC BLK = Common WHT = Output ORN = NPN / PNP Output Selector Opt.
- 7 - Installation CS2000-QD Wiring: The CS2000-QD comes with a 6" quick disconnect M12 - 4 pin male cable/connector (Turck P/N RS4.4T-2). Refer below for wire designations.
ACME LABELS ACME LABELS AC ACME LABELS ACME LABELS ACME LABELS ACME LABELS - 8 - Operation Label Placement: For best results, position straight edge of label under the sensing area. Try to avoid sensing on rounded corners or other curved areas. Refer to diagram below.
- 9 - Operation LED Functions: Yellow - comes on when label backing (web) is under the sensing area Red - comes on when output is active - NPN sinking or PNP sourcing Green - comes on when.
- 10 - Adjusting Label Sensitivity Overview: The CS2000 will automatically adjust its label sensitivity, to the optimal setting, by simply depressing a push-button.
- 11 - Missing Label Compensation Overview: The CS2000 has the capability to detect a single missing label and output a stop pulse as though the label were present. In order for Missing Label Compensation to function properly the operator must first: a) have Pulse Output selected - see Program Mode (page 12) for more information.
- 12 - Program Mode Entering Program Mode: Program Mode is used to change any or all of the Operation Features. To enter Program Mode depress the push-button until the yellow and green LED's begin toggling (30 sec.), then release. The LED's will then output the current set-up configuration (and every 3 sec.
- 13 - Specifications General: Power Supply..................................................... 10-30 VDC, reverse polarity protected Power Consumption............................................ 50mA max. Output................................
- 14 - Specifications Dimensions: CS2000 0.44 11.2 0.625 1.00 25.4 0.625 15.9 79.4 3.125 50.8 15 0.59 2.00 0.22 5.6 0.75 19.1 0.50 12.7 15.9 0.09 Sensing Area 15.9 0.625 76.2 3.00 EASY SETUP WEB OUT LABEL 13.5 0.53 1.00 88.9 3.50 25.4 9.5 0.38 2.4 1. 2.
- 15 - Cleaning Instructions Cleaning Instructions: 1. Begin by removing the sensor lid's 4 screws with a 1/16" L wrench. 2. Gently lift the sensor's circuit board out by grasping the switch and pulling upward. Do not remove the insulation tape.
- 16 - Warranty Terms & Conditions Warranty: The CS2000 Label Sensor is warranteed for a period of two (2) years from the time of purchase. Control Technologies guarantees the CS2000 to be free from defects in materials or workmanship, and that, if used correctly will perform within specifications.
Ein wichtiger Punkt beim Kauf des Geräts Contec CS2000-QD (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Contec CS2000-QD noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Contec CS2000-QD - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Contec CS2000-QD reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Contec CS2000-QD erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Contec CS2000-QD besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Contec CS2000-QD verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Contec CS2000-QD. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Contec CS2000-QD gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.