SE95004 Rev . 4 Operators Manual Installation, Operation & Service Electric T able T op Kettles For units built after August 1999 MODELS: Single Kettles KET -3-T KET -6-T KET -12-T KET -20-T* T win Kettles TKET -3-T TKET -6-T TKET -12-T * Floor T ype Leg Mount 1333 East 179th S t.
T ABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instructions .
1 GENERAL Installation of the kettle must be accomplished by qualified electrical installation personnel working to all applicable local and national codes. Improper installation of pr oduct could cause injur y or damage. This equipment is built to comply with applicable standards for manufactur ers.
2 ASSEMBL Y T able-T op Models (3, 6 & 12 gallon) Base Mounting Diagram T able-top models (3, 6 & 12 gallon - single and twin) must be positioned on a firm, level stand, or existing counter top, and bolted in place. These models are supplied with four threaded mounting bushings welded to the underside of the base.
3 W A TER The sealed jacket of the electric kettle is precharged with the corr ect amount of a water based formula, and therefore, no water connection is requir ed to the kettle jacket. The kettle can be equipped with optional hot and/or cold water faucet, requiring 1/2" copper tubing as supply lines.
4 6 5 4 3 2 1 7 OPERA TING INSTRUCTIONS General Parts Drawing ITEM # DESCRIPTION FUNCTION 1. Tilting Handle Used for tilting the kettle. 2. V acuum/Pressur e Gauge Indicate steam pressur e in PSI inside steam jacket as well as vacuum in inches of mercury .
5 OPERA TING THE KETTLE DO NO T LEAN ON OR PLA CE OBJECTS ON KETTLE LIP . SERIOUS INJUR Y COULD RESUL T IF KETTLE TIPPED O VER, SPILLING HO T CONTENTS. 1. Before turning kettle on, read the V acuum/Pressur e Gauge ( 2 ). The gauges needle should be in the green zone.
6 MARINE LOCK Y our unit is equipped with a marine lock to prevent accidental tilting. The following procedur e should be used to tilt the kettle. 1. Grasp the tilt handle. 2. Hold the latch down to unlock tilting mechanism. 3. Pull the handle to tilt kettle.
7 MARINE LOCK Use a small nylon bristle brush to remove food and debris from pivot point. If lock is still sticking have maintenance disassemble and clean pieces individually and reassemble. Disassembly 1. Disconnect power from kettle. 2. Remove console cover from top of kettle's console.
8 F AUCET ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 1. KE50825-2 3/4" Spout (KET -3/6/12/20-T) . . . . . . .1 KE50825-9 3/4" Spout (TKET -3/6/12-T) . . . . . . . . .1 2. F A95022 Retaining Ring . . . . . . . . . . . . . . . . . .1 3. F A05002-19 "O" Ring .
9 KETTLE BOTTOM & SIDE ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE50556-1 Probe, Low W ater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE51723 Safety V alve, 50 PSI, 1/2" . . . . . . . . . . . . . . .
10 2 3 4 5 1 CORD & PLUG OPTION ITEM NO . P ART NO . DESCRIPTION QTY . FOR KET -6-T (SW) (200-240V AC, 3PH, 50/60Hz 1. KE02113-1 Cord Plug Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE54819-1 Plug (30A) .
11 CONSOLE COMPONENTS & MARINE LOCK 5 4 6 7 10 9 8 11 12 13 26 23 5 2 3 1 14 15 25 16 18 19 20 21 17 24 22.
12 CONSOLE COMPONENTS & MARINE LOCK ITEM NO . P ART NO . DESCRIPTION QTY . Single / T win 1. SE00114 Potentiometer with ON/OFF Switch, c/w Item #2 . . . . . . . . . . . . . . . . . . . . . . 1 / 2 2. KE51005 Rubber Boot . . . . . . . . . . . . . .
13 NOTE: Item # 14 to be tack welded flush outside in the gearbox housing (item #1 ). Do not damage the outside edges of the gearbox housing when tack welding. 1 14 2 2 3 7 8 7 9 3 5 6 20 19 22 23 21 25 10 11 4 12 13 16 15 12 24 18 17 TIL TING GEARBOX ASSEMBL Y (12 gallon kettle only) ITEM NO .
14 ELECTRICAL P ANEL ITEM NO . P ART NO . DESCRIPTION QTY . Single / T win 1. KE54761 T er minal Block Mounting Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 / 2 2. SK50055-1 T er minal Block . . . . . . . . . . . . . . . . . . . .
15 Cleveland Range equipment requir es little preventative maintenance. We do however pr ovide the following chart as a guideline for inspection and maintenance to keep your unit functioning at 100%.
16 BEARING LUBRICA TING PROCEDURE 1. Remove console cover . 2. Loosen two Allen screws on locking ring. 3. Pull locking ring to center of trunnion. 5. Clean newly exposed sections of trunnion. 6. Grease trunnion between kettle and console. 7. Repack outer needle bearing.
17 CALIBRA TING PROCEDURE 1. Insure the unit has a vacuum befor e you begin calibrating procedur es. If unit requires venting r efer to Kettle V enting Instructions on page 18 of this manual. 2. T ur n kettle ON and set temperatur e dial to 10 ( Max.).
3. Remove Guard Bracket (A). 4. Pull Pressur e Relief V alve (B) open to insure vessel is not pressurized. 5. Remove Pressur e Relief V alve (B). 6. Replace Pressur e Relief V alve (B) with Street Elbow (C). 7. Add distilled water (D) through the Str eet Elbow (C), using a funnel if necessary .
MARINE LOCK TESTING PROCEDURE 1. Check that lock clears stop pin on side box without rubbing when kettle is tilted (Figure A ). 2. Check side to side play . Lock should remain fully over stop pin when pushed to it's maximum side to side play (Figure B ).
20 Fault Isolation Pr ocedur e Step T est 1. Is there pr oper incoming voltage at terminal block? 2. Is the red LED illuminated? 3. Is the green LED illuminated? 4. Do both contactors energize? 5. Measure continuity acr oss safety thermostat. Is it an open circuit? 6.
21 Fault Isolation Pr ocedur e Step T est 1. In a cold state, does the pressur e gauge read in the gr een zone? 2. Do the contactors shut off too early? (before r eaching nor mal maximum operating pressur e.) 3. Does the green LED r emain illuminated after the contactors shut off? 4.
22 5. Remove kettle thermistor and allow to cool. Remove edge connector from control box. T est resistance acr oss edge connector's pins #2 and #7. Is it approximately 100,000 ohms? 6. T urn the potentiometer on the control box clockwise to increase the maximum operating temperature.
23 WIRING DIAGRAM 3 Gallon Kettles 200-240v Single Phase Only 380-480v Single Phase Only.
24 WIRING DIAGRAM 6-20 Gallon 200-240v 380-600v.
25 25 ON MARCHE ENCENDIDO ACCESO AN P AUSE, INTERRUPTION P AUSE, INTERRUPTION P AUSA, INTERRUPCION P AUSA, INTERRUZIONE P AUSE, UNTERBRECHUNG RESET R É ENCLENCHER RECONECT AR RESET NULLSTELLEN STOP O.
26 26 LOW W A TER NIVEAU BAS DE L'EAU NIVEL DE AGUA BAJO LIVELLO BASSO W ASSERST AND NIEDRIG IGNITION F AILURE P ANNE D'ALLUMAGE F ALLO DE ENCENDIDO MANCA T A ACCENSIONE Z Ü NDUNGSFEHLER CO.
Ein wichtiger Punkt beim Kauf des Geräts Cleveland Range KET-3-T (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cleveland Range KET-3-T noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cleveland Range KET-3-T - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cleveland Range KET-3-T reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cleveland Range KET-3-T erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cleveland Range KET-3-T besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cleveland Range KET-3-T verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cleveland Range KET-3-T. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cleveland Range KET-3-T gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.