English Español P ortuguês Deutch Italiano Français INSTRUCTION MANUAL FOR DIGIT AL BLOOD PRESSURE MONIT OR MODEL CH607 - Eng 1 - TIME S E T M O D E M E M O R Y DATE M SYS.
General remarks on blood pres- sure and blood pressure measure- ment • If the cuff is to be deflated quickly , depress “Start/ Stop” switch. • The attached cuff is suited for a wrist cir cum- ference of 13.5 cm to 19.5 cm. • When attaching the cuff, the body of the blood pressure monitor should be placed on the in- side of your wrist.
English Español P ortuguês Deutch Italiano Français • Measure blood pressure where the room tem- perature is about 20 ° C. DO NOT measure blood pressure when it is too cold (below 10 ° C)or too hot (above 40 ° C) in the room . • DO NOT tr y to measure blood pressure imme- diately after drinking coffee or tea or smoking.
Precaution for maintenance • Do NOT store the blood pressure meter where it will be exposed to direct sunlight, high tem- perature (over 60 ° C), low temperature (below - 20 ° C), high relative humidity (over 95%) or in a dusty place . • Do NOT expose the blood pressure meter to undue force or vibration, or drop it.
English Español P ortuguês Deutch Italiano Français WHO blood pressure c lassifica- tions Standard for assessment of high or low blood pres- sure without regard to age, have been established by the World Health Organization (WHO), as shown in the chart.
TIME SET M O D E M E M O R Y DATE M SYS. mmHg m m H g P DIA. mmHg PULSE /M IN START/ ST OP CH607 - Eng 6 - LCD display Wrist cuff Recall memory button Start/Stop button Batteries “ AAA ” 1.5V × 2 DEVICE DESCRIPTION Carrying case Setting button Mode button 1.
English Español P ortuguês Deutch Italiano Français - Eng 7 - 2. Description of display symbols Month Date Hour Minute Afternoon time Systolic rate Pulse rate Pulse symbol Battery weak displa y Err.
- Eng 8 - BA TTERY REPLACEMENT CLOCK MODE 1. T o use this unit, you must install batteries, If the battery mark “ ” is displayed, you must change both batteries. 2. Open battery cover as illustrated. Replace the two batteries, matching the (+) and ( – ) polari- ties on each battery with the polarity marks on the case.
English Español P ortuguês Deutch Italiano Français 1 . Attaching of wrist cuff The blood pressure is measured at the wrist. Therefore, rolling up the sleeve is no longer necessary. The pressure cuff has integrated into the wristlet. Wind the wristlet around your left wrist.
- Eng 10 - • Apply the wrist cuff to the wrist and make sure it is not too loose or too tight. If the wrist cuff is applied inappropriately , it may display an er - ror or abnormal values. Pull the wristlet tight and close the “ Burr closure ” .
English Español P ortuguês Deutch Italiano Français - Eng 11 - Do not move or talk while taking the blood pres- sure measurement. 4) When pressurization is completed, the auto- matic air release system will gradually reduce cuff pressure, and measuring mark “ Heart- mark ” will flash on the display indication that measuring is in progress.
- Eng 12 - 5. Memory recall Y ou can recall stored data by pressing the “ Memor y ” switch, except when performing a measurement. • Up to 99 sets of measurement results are auto- matically stored in memory , and memory cell No. 1 is always used to store the oldest set of results.
English Español P ortuguês Deutch Italiano Français - Eng 13 - DISPLA Y MARK CONDITION / CA USE CORRECTIVE A CTION ERROR DESCRIPTION OF DISPLA Y MARKS Mark appears in the measurement condition and flashes when pulse is detected. Measurement in progress.
- Eng 14 - SPECIFICA TIONS Model Number CH607 Measuring Principle Oscillometric System Measurement Localization Left Wrist Arm Cuff Preformed cuff Arm Circumference Range 13.5 to 19.5 cm Measurement Range Pressure 0 - 300 mmHg Pulse 40 - 199 Pulse / Min.
Ein wichtiger Punkt beim Kauf des Geräts Citizen CH-607 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Citizen CH-607 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Citizen CH-607 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Citizen CH-607 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Citizen CH-607 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Citizen CH-607 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Citizen CH-607 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Citizen CH-607. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Citizen CH-607 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.