Benutzeranleitung / Produktwartung 97750 des Produzenten Chicago Electric
Zur Seite of 16
P AINT SPRA YER HVLP-ELECTRIC Model 97750 SET UP AND OPERA TING INSTRUCTIONS Diagrams within this manual may not be drawn proportionally . Due to continuing improvements, actual product may differ slightly from the product described herein. Distributed exclusively by Harbor Freight T ools ® .
Page 2 SKU 97750 For technical questions, please call 1-800-444-3353. SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures.
Page 3 SKU 97750 For technical questions, please call 1-800-444-3353. Unmodied plugs and matching out - lets will reduce risk of electric shock. A void body contact with grounded b. surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is grounded.
Page 4 SKU 97750 For technical questions, please call 1-800-444-3353. Disconnect the Power Cord (34) c. from the power source before mak- ing any adjustments, changing ac- cessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally .
Page 5 SKU 97750 For technical questions, please call 1-800-444-3353. Never release the Lower Cover (24) 7. while the Cup (27) is pressurized. Industrial applications must follow 8. OSHA requirements. Make sure air intake guard is in 9. place before use.
Page 6 SKU 97750 For technical questions, please call 1-800-444-3353. GROUNDING TO PREVENT ELECTRIC SHOCK AND DEA TH FROM INCORRECT GROUNDING WIRE CONNECTION: Check with a qualied electrician if you are in doubt as to whether the outlet is properly grounded.
Page 7 SKU 97750 For technical questions, please call 1-800-444-3353. Double insulated tools may be used 2. in either of the 120 volt outlets shown in the preceding illustration. (See Outlets for 2-Prong Plug.) Extension Cords Grounded 1. tools require a three wire extension cord.
Page 8 SKU 97750 For technical questions, please call 1-800-444-3353. SPECIFICA TIONS Electrical Requirements 120 V~ / 60 Hz / 450 W atts 5.5 Amps (Start Up) 3.3 Amps (Load & No Load) Motor Speed: 30,000 RPM Power Plug: 2-Prong Power Switch: ON/OFF Rocker Spray Cup Capacity 1 Quart Output Pressure 1.
Page 9 SKU 97750 For technical questions, please call 1-800-444-3353. W ork Piece and Work Area Set Up Designate a work area that is clean 1. and well-lit. The work area must not allow access by children or pets to prevent injury and distraction. Route the Power Cord (34) along a 2.
Page 10 SKU 97750 For technical questions, please call 1-800-444-3353. FIGURE C FLA T/OPEN ROUND/CLOSED 9. After setting up a piece of scrap mate- rial, squeeze the T rigger (6) in short bursts while turning the Fluid Control Screw (19) counterclockwise and observe the pattern for consistency .
Page 1 1 SKU 97750 For technical questions, please call 1-800-444-3353. MAINTENANCE AND SER VICING Procedures not specically explained in this manual must be performed only by a qualied technician.
Page 12 SKU 97750 For technical questions, please call 1-800-444-3353. may still remain in the Spray Gun. Point the Gun into the spent solvent container and squeeze the T rigger (6) again to make sure no air re- mains. Remove the T op Cover (22) and • soak it in solvent/water until it is clean.
Page 13 SKU 97750 For technical questions, please call 1-800-444-3353. TROUBLESHOOTING - GENERAL IMPORT ANT : Improper cleaning is a common reason for the unit not to work properly . Most problems can be avoided or remedied with prompt, thorough cleaning.
Page 14 SKU 97750 For technical questions, please call 1-800-444-3353. TROUBLESHOOTING - SPRA Y P A TTERN IMPORT ANT : Improper cleaning is a common reason for the unit not to work properly . Most problems can be avoided or remedied with prompt, thorough cleaning.
Page 15 SKU 97750 For technical questions, please call 1-800-444-3353. P ARTS LIST & ASSEMBL Y DIAGRAM 13 34 33 Shoulder Strap (35) not shown. Part # Description Part # Description 1 Seal Nut 19 F.
Page 16 SKU 97750 For technical questions, please call 1-800-444-3353. LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durabil.
Ein wichtiger Punkt beim Kauf des Geräts Chicago Electric 97750 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Chicago Electric 97750 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Chicago Electric 97750 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Chicago Electric 97750 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Chicago Electric 97750 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Chicago Electric 97750 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Chicago Electric 97750 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Chicago Electric 97750. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Chicago Electric 97750 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.