50GS, 50GX Single Packaged Electric Cooling Units Installation, Start-Up, and Operating Instructions 50GS Sizes 018-060, 50GX Sizes 024-060 NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue.
Before performing service or maintenance operations on system, turn off power to unit. Turn off accessory heater power switch, if applicable. Electrical shock can cause personal injury. Recognize safety information. This is the safety-alert symbol . When you see this symbol in instructions or manuals, be alert to the potential for personal injury.
Accessory lifting kit is only to be used with Small Packaged units which have a composite base pan with molded rigging holds. INSPECTION Prior to initial use, and at monthly intervals, all rigging brackets and straps should be visually inspected for any damage, evidence of wear, structural deformation, or cracks.
2. Place each of the four (4) metal lifting brackets into the rigging holds in the composite pan. 3. Tighten the ratchet strap unit tight. Lifting brackets should be secure in the rigging holds. 4. Attach the clevis or hook of sufficient strength to hole in the lifting bracket (See Fig.
Fig. 4A— Roof Curb Dimensions UNIT SIZE ODS CATALOG NUMBER A IN. (MM) B IN. (MM) C IN. (MM) D IN. (MM) 50GS018-042 50GX024-036 CPRFCURB006A00 8 (203) 11(279) 16-1/2 (419) 28-3/4 (730) CPRFCURB007A00.
Fig. 4B—50GS and 50GX Unit Corner Weights CORNER # 50GS 50GX 018 024 030 036 042 048 060 024 030 036 042 048 060 1 58 60 59 62 76 69 84 76 84 85 71 78 85 2 47 50 48 50 50 45 54 49 60 60 55 56 66 3 5.
Lifting point should be directly over the center of gravity for the unit. Step 6—Connect Condensate Drain NOTE: When installing condensate drain connection be sure to comply with local codes and restrictions. Models 50GS and 50GX dispose of condensate water through a 3/4 in.
CONFIGURING UNITS FOR DOWNFLOW (VERTICAL) DIS- CHARGE Before performing service or maintenance operations on the system, turn off main power to unit and install lockout tag or electrical shock could result. 1. Open all electrical disconnects and install lockout tag before starting any service work.
5. It is recommended that the unit base insulation around the perimeter of the vertical return-air opening be secured to the unit base with aluminum tape. Applicable local codes may require aluminum tape to prevent exposed fiberglass. 6. Cover both horizontal duct openings with the duct covers from the accessory duct cover kit.
Failure to follow these precautions could result in damage to the unit being installed: 1. Make all electrical connections in accordance with NEC ANSI/NFPA (latest edition) and local electrical codes governing such wiring. In Canada, all electrical connec- tions must be in accordance with CSA standard C22.
Table 4—Electrical Data—50GS UNIT 50GS SIZE V-PH-HZ VOLTAGE RANGE COMPRESSOR OFM IFM ELECTRIC HEAT POWER SUPPLY Min Max RLA LRA FLA FLA Nominal Kw* FLA MCA Max Fuse orCkt Bkr MOCP 018 208/230–1–60 187 254 9 45 0.8 1.8 -/- 3.8/5.0 5.4/7.2 7.5/10.
Table 5—Electrical Data—50GX UNIT 50GX SIZE V-PH-HZ VOLTAGE RANGE COMPRESSOR OFM IFM ELECTRIC HEAT POWER SUPPLY Min Max RLA LRA FLA FLA Nominal Kw * FLA MCA Max Fuse or Ckt Bkr MOCP 024 208/230–1–60 187 253 10.9 54.0 0.9 2.0 -/- 3.8/5.0 5.4/7.
Run the low-voltage leads from the thermostat, through the inlet hole, and into unit low-voltage splice box. Locate five 18-gage wires leaving control box. These low-voltage connection leads can be identified by the colors red, green, yellow, brown, and white (See Fig.
leak. Leak test all refrigerant tubing connections using electronic leak detector, halide torch, or liquid-soap solu- tion. If a refrigerant leak is detected, see Check for Refrigerant Leaks section. c. Inspect all field- and factory-wiring connections.
Fig. 12—Wiring Diagram (208/230-60-1) C99003 15.
Fig. 13—Wiring Diagram (208/230-60-3) C99004 16.
Fig. 14—Wiring Diagram (460-60-3) C99005 17.
When evaluating the refrigerant charge, an indicated adjust- ment to the specified factory charge must always be very minimal. If a substantial adjustment is indicated, an abnormal condition exists somewhere in the cooling system, such as insufficient airflow across either coil or both coils.
inspected at least once each year by a qualified service person. To troubleshoot heating or cooling of units, refer to tables at the back of the book. The following are 50GS Cooling Charging Charts: The following are 50GX Cooling Charging Charts: NOTE TO EQUIPMENT OWNER: Consult your local dealer about the availability of a maintenance contract.
The ability to properly perform maintenance on this equip- ment requires certain expertise, mechanical skills, tools, and equipment. If you do not possess these, do not attempt to perform any maintenance on this equipment other than those procedures recommended in the User’s Manual.
Errors made when reconnecting wires may cause improper and dangerous operation. Label all wires prior to disconnec- tion when servicing. The minimum maintenance requirements for this equipment are as follows: 1. Inspect air filter(s) each month. Clean or replace when necessary.
AIR FILTER Never operate the unit without a suitable air filter in the return-air duct system. Always replace the filter with the same dimensional size and type as originally installed.
c. On all units remove blower assembly from unit. Remove screws securing blower to blower partition and slide assembly out. Be careful not to tear insulation in blower compartment. d. Ensure proper reassembly by marking blower wheel and motor in relation to blower housing before disassembly.
CONDENSER COIL, EVAPORATOR COIL, AND CONDEN- SATE DRAIN PAN Inspect the condenser coil, evaporator coil, and condensate drain pan at least once each year. The coils are easily cleaned when dry; therefore, inspect and clean the coils either before or after each cooling season.
System under pressure. Relieve pressure and recover all refrigerant before system repair or final unit disposal to avoid personal injury or death. Use all service ports and open all flow-control devices, including solenoid valves.
Table 10—Troubleshooting—Cooling SYMPTOM CAUSE REMEDY Compressor and condenser fan will not start. Power Failure Call power company Fuse blown or circuit breaker tripped Replace fuse or reset circ.
START-UP CHECKLIST (REMOVE AND STORE IN JOB FILE) I. PRELIMINARY INFORMATION Model No ............................................................................................................................................................. Serial No .
Copyright 2003 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 50gsgx4si Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 6 Tab 6 8 PC 101 Catalog No.
Ein wichtiger Punkt beim Kauf des Geräts Carrier SINGLE PACKAGED ELECTRIC COOLING UNITS 50GS (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Carrier SINGLE PACKAGED ELECTRIC COOLING UNITS 50GS noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Carrier SINGLE PACKAGED ELECTRIC COOLING UNITS 50GS - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Carrier SINGLE PACKAGED ELECTRIC COOLING UNITS 50GS reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Carrier SINGLE PACKAGED ELECTRIC COOLING UNITS 50GS erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Carrier SINGLE PACKAGED ELECTRIC COOLING UNITS 50GS besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Carrier SINGLE PACKAGED ELECTRIC COOLING UNITS 50GS verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Carrier SINGLE PACKAGED ELECTRIC COOLING UNITS 50GS. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Carrier SINGLE PACKAGED ELECTRIC COOLING UNITS 50GS gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.