Benutzeranleitung / Produktwartung HRVCCSVB1100 des Produzenten Carrier
Zur Seite of 14
ERVC CSVB1100, ERVCCSHB1100 HRVCCSVB1100, HRVC CS HB1100 Energy / Heat Recovery V entilator Installation Instructions NOTE : Read the en tire in structio n man ual b efo re starting th e installatio n . T ABLE OF CONTENTS P AGE SAFETY CONSIDERA TIONS 1 .
2 INTRODUCTION Th e En er gy /H eat Reco v ery V entilato r (E R V/HR V) is used to exc ha nge i ndoor s t a le a i r wit h outs ide fre s h ai r . The uni t is equ ip p ed with a sp ecial energy /h eat reco very co re w hich t ransfers both s e ns ibl e and/ or l a t ent hea t bet we en t he f re s h i ncom ing ai r and st a l e exha us t a ir .
3 UNIT INST ALLA TION UNIT DAMAGE HAZARD Failu re to follo w this cautio n may resu lt in eq u ipm en t dam age or imprope r ope r at i on. Do not inst a ll ER V/H R V in a cor ros i ve or conta mi na t ed at mos phe r e. CAUTION ! Mo unt Unit The ER V/ HR V ca n be suspe nde d fr om floor j oi st s us i ng cha i ns a nd 4 sprin g s.
4 Con nect Du cts to E R V/HR V PROPERTY DAM AGE HAZARD Failu re to follo w this cautio n may resu lt in m ino r pro p erty dam age fr om swe at i ng duct or loss of unit ef fic i e ncy and capacity. If ER V/H R V duc t wor k i s ins ta l le d i n a n uncondi ti one d space, in su lated flex ib le d u ct is req uired .
5 bet we e n wal l c ontr ol a nd ER V/HR V conne c tor fol l owing col or code . (Se e Fig. 5 a nd 10. ) R epl a c e t op c ove r a s s em bly . NOTE : ER V/ HR V wal l c ontr ol a nd ci rc ui t boar d opera t e on 12VDC. YELLOW YR G B RED GREEN BLACK A98383 Fig.
6 OPERA TING THE E R V/HR V WITH THE INF INITY C ONTR OL Th e v en tilator h as fo u r settin gs in h eating m o de an d th ree settin gs in coo lin g mo d e. Heating: AU TO - - th e v entilato r selects th e sp eed b ased o n i ndoor humi dit y a nd outdoor te mpe r a tur e .
7 BALANCING ER V/HR V Bal a nc ing i nt ake and e xha us t ai r fl ow i s ve ry i mpor t ant f or proper sys t e m ope ra t i on and opt i mum pe r for ma nc e when appl ying a n ER V/HR V . U n it balan cin g p rev ents a p o sitiv e an d /or n eg ative pre s s ure wi t hin the home .
8 VENTILA TION EV ALUA TION UNIT DAMAGE HAZARD Failu re to follo w this cautio n may result in red u ced u nit efficiency , capacity or u n it life. DO NOT use H R V dur ing cons t ruc t i on of a hous e or when sa ndi ng drywa ll . Thi s type of dus t ma y dama ge s yst e m.
9 NOTE : The cor e shoul d only be s e r vic e d w hen outdoor temp eratu re is 60 ° Ft o7 5 ° F( 1 6 ° Ct o2 4 ° C) and it is dr y . UNIT COMPONENT DAM AGE HAZARD Failu re to follo w this cautio n may resu lt in eq u ipm en t dam age or imprope r ope r at i on.
10 If the int egr a te d c ont r ol LED of t he uni t i s f l as hi ng, t hi s me a ns t he uni t sens or s de te c t ed a pr obl e m. See the ta bl e bel ow t o know wher e on t he unit t he pr oble m occ ur s . T able 5 – T r ouble s hoot ing LED flash es G REEN.
11 T able 6 – T emp eratu re / Ohm Relationship TEMP . ( ° F/ ° C) RESISTANCE (OHMS) --- 9 / --- 2 3 78330 --- 8 / --- 2 2 74610 --- 6 / --- 2 1 71100 --- 4 / --- 2 0 67770 --- 2 / --- 1 9 64570 --- .
12 CONNECTION DIAGRAM Line voltage factory wiring Class 2 low voltage factory wiring Class 2 low voltage field wiring M1 A1 T1 R1 Field wiring remote control (see notes 3, 4) 120V, 60Hz W1 F1 J5 J7 J6 J4 ELECTRONIC ASSEMBLY 1 2 3 1 2 1 2 1 2 3 1 2 3 4 12 12345 1 2 3 4 5 J8 J9 J11 J10 1 2 J12 J13 J14 10 9 8 7 6 5 4 3 2 1 M2 C1 C2 24V class 2 9.
13 120V, 60Hz Neutral 120V, 60Hz Line CPU K2 K4 K5 J5-2 J10-1 J10-2 Exhaust fan motor Supply fan motor J5-1 J5-3 J7-2 J7-1 J4-1 J4-3 J6-2 J6-1 K1 K3 K2 J9-1 J9-2 J9-3 J4-2 J9-4 Exhaust fan motor capac.
14 These products earned the ENERGY ST AR ® by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EP A. They meet ENERGY ST AR requirements only when used in Canada. S ER VCCSVB1100 S ER VCCSHB1100 S HR VCCSVB1100 S HR VCCSHB1100 Energy Star (Canada) Copyright 2010 Carrier Corp.
Ein wichtiger Punkt beim Kauf des Geräts Carrier HRVCCSVB1100 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Carrier HRVCCSVB1100 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Carrier HRVCCSVB1100 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Carrier HRVCCSVB1100 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Carrier HRVCCSVB1100 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Carrier HRVCCSVB1100 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Carrier HRVCCSVB1100 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Carrier HRVCCSVB1100. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Carrier HRVCCSVB1100 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.