Copy right 20 02 Carrie r Cor poration Form 50AH-6PD Single Pac kage Coolin g Units F eatur ing: • compact des ign • fle xibi lity • easy maint enance • hig h quali ty and reli abilit y • qu.
2 locatio n is ideal for th e mainten ance technicia n, and five acce ss pane ls, easi ly removed, provide quick a nd convenient acces s to all co mponents wh en needed.
3 LEGEND *Shipping weights include base unit plus packaging. †If components are to be split, additional refr igerant will be needed. **T wo-speed motor.
4 Thermostat and subb ase — Attractive wall-mounted 24-v accesso ry provide s precise temp erature co ntrol. Automatic a nd Manual changeover mod els availabl e. A thermostat subbase is av ailable that works with Cycle- LOC™ circuitry. If a safety device trips, compressor locks out and su bbase war ning ligh t (LK OUT) al erts occupa nt.
5 Base unit dimensions DIME NSIONS (f t-in .) UNIT 50AH ABCD E 024 2-5 2-1 5 / 8 1- 5 3 / 4 1-2 1-1 036 2-4 3 / 4 2-2 1- 5 3 / 4 1-2 1-1 048 2-5 2-3 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 060 2-4 3 / 4 2-2 3 .
6 I De ter m ine co oling req uir eme nts at desi gn conditions. Given: Gross Cooling Capacity Required (TC) . . . . . . . . . . . . . . . . . . 39,000 Btuh Sensible Heat Capacity (SHC) . . . . . . 30,500 Btuh T emperature of Air Entering Condenser . .
7 GROSS COOLING CAP ACITIES (cont) LEGEN D NO TES: 1. P e rformance b ased on n ominal con denser airflow l isted in physical dat a table on page 3 . 2. SHC is based on 80 F db temp erature of air ent ering th e coil. Bel o w 80 F db , sub tract (co rr f actor x c fm) from SH C.
8 BEL T DRI VE EV AP ORA T OR F AN PER FORMANC E (Special Order Only, Pricing and or dering on related price pa ges.) LEGEND NO T E: Pulley setti ng must be adjusted to limit cfm to 450 c fm/ton maximum. Unit operation be yond that limit may result in blow-off and condensate problems.
9 ELECTRIC HEA TER ST A TIC PRESSURE DROP (in. wg) NO T E: Abov e electr ic heaters are not UL (Underwriters’ Laboratories) or CSA (Canadian Standards Association) listed f or use with optional high-static e vapor at or-fan motor (048, 060 units only).
10 ELECTR IC HEA TER DA T A LEGEND *May be field conv er ted t o single-phase units, see electric heat inst allation instructions. NO T E: Separate pow er source is required for all heaters. Control from base unit 50AH (24 v). ELECT RIC HE A T ER UNIT 88EN USED WITH UNIT 50AH V- P H (60 Hz) CAP .
11 T ypical w iring schematic 50AH048,060 — 230-1- 60 UNITS LEGEND AHA — Adjustable Heat Anticipator C— Contactor Compressor CB — Circuit Breaker CC — Cooling Compensator E Q UIP GND — Equ.
12 T ypical w iring schematic (c ont) 50AH036,048,060 — 208/2 30- 3-60 UNITS LEGEND AHA — Ad justab le Hea t Anticipator C— Contactor Compres sor CB — Circuit Breaker CC — Cooling Compensato.
13 Application d ata OUTDOOR-AIR TEMPE R A TURE OPERA TING LIMITS (F) Field splitting inst ructions — If componen ts are spli t, maximum length of refrigerant tubing to be used is 50 ft, assumi ng componen ts are installed in same horizo ntal plane.
14 Indoor P a c k aged Unit HV AC Guide S pecific ations — Se ction 15 787 Size Range: 2 to 5 T ons, Nomina l Carrier Mode l Number: 50AH Part 1 — General 1.01 SYSTEM DESCRIPTION Indoor mo unted, electricall y controll ed packaged horizontal cooling unit utilizing a hermetic type scroll compressor .
15 I. O perating char acteristics: 1. Unit shall operate using refrigerant R-22. 2. Unit sha ll be desi gne d for indo or sus pended horiz onta l moun ting an d ope rati on. J. Elec trical Requirements Unit shall ha ve single point power connection to leads in ter minal box.
Manufa cturer reser ves the right to disconti nue, or change at any time, specificat ions or designs wi thout noti ce and without incurrin g obligations.
Ein wichtiger Punkt beim Kauf des Geräts Carrier 50AH (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Carrier 50AH noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Carrier 50AH - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Carrier 50AH reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Carrier 50AH erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Carrier 50AH besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Carrier 50AH verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Carrier 50AH. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Carrier 50AH gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.