Benutzeranleitung / Produktwartung 40QAC des Produzenten Carrier
Zur Seite of 26
40QAC / 38HDR 40QAQ / 38QR R Ceiling - - - S uspen ded Duct F r ee Split S ys tem Size s 018 to 060 Installation Instructions the environmentally sound refrigerant 40QAC, QA Q Unit 38HDR, QR R Unit NOTE : Read the en tire in structio n m an ual b efo re starting the installatio n .
2 DIMENSIONS - - INDOOR NO TES: 1. Dimensions in [ ] ar e in millimeters. 2. Direction of airflo w. 3. Standard unit clearances are as fol lows: • 0 in. on top a nd rear • 3i n .o nl e f ts i d e • 12 in. on r ight side • 36 in.on bottom (When facing unit discharge.
3 4 3/16" H G L A B J N P E FD 7 1/2" 2 1/2" 1" 8" 4 1/2" 1 7/16" 11/16" C K N UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D E F G H J KL M N P OPERATING WEIGHT.
4 106.4 17.5 H G L A B J K N P E FD C 190.5 63.5 25.4 203.2 38.1 114.3 36.5 UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D E F G H J KL M N P OPERATING WEIGHT(KG) SHIPPING WEIGHT(KG) SHIPPING DIMENSIONS (L x W x H) 38HDR018 1 X O O O 638.2 938.2 369.9 406.
5 4 3/16" 11/16" J K N P E FD C 7 1/2" 2 1/2" UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D E F G H J KL M NP OPERATING WEIGHT(lbs) SHIPPING WEIGHT(lbs) SHIPPING DIMENSIONS (L x W .
6 106.4 17.5 J K N P E FD C 190.5 63.5 N UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D E F G H J KL M NP OPERATING WEIGHT(KG) SHIPPING WEIGHT(KG) SHIPPING DIMENSIONS (L x W x H) 38QRR018 0 X O O O 638.2 938.2 369.9 406.4 595.3 436.6 435.0 558.8 330.2 168.
7 Th ese in stallation in stru ction s cov er the in stallation o f th e matched system s listed in table 2. Parts List Ind oor Unit The fol lowing it ems a re i nclude d wit h the i ndoor unit : T ab le 1 – Installa tio n Ma terials Pa rt N o . Name o f Part Qt y .
8 Refrig erant Charge Th e 3 8H DR and 38 QR R u n its can be m atched w ith multip le outdoor unit s and thus addi ti onal c har ge might be re quir ed when ma tc hed wi th t he 40QAC or 40QA Q unit s. T able 5 – A ddit ional Char ge Add itio nal Charg e l b.
9 Oper ating R ange En su re that th e system o perates w ithin th e ap plicatio n g uid elines show n in t he fol lowing t abl es . Cooling ope rat ing ra ng e: Maximum Mi nimum DB _ F( _ C) WB _ F( _ C) DB _ F( _ C) WB _ F( _ C) Outdoor Unit 125 (51.
10 3. Mount Uni t - - the ins tal lat ion loc at ion s hould ha ve alr ea dy bee n ide nti fie d t aki ng into acc ount the pipi ng lengt h, wi ri ng and p ip ing ,co n nectio n s, and clearances.
11 Whe n mount ing bra cket s, sel ec t the proper type of har dwa re f rom the g u idelin es belo w . S ee Fig . 1 4 PERSONAL I NJURY AND/OR EQUI PMENT DAMAGE HAZARD Failu re to follow th is cautio n may resu lt in perso nal injury and / or eq u ip men t d amag e.
12 Comp lete Ou tdo or Refrig erant Pi pi ng Conn ec- tions Foll ow the f oll owing gene ra l guidel ines : 1. Use r ef rige ra nt gr ade f ie ld – suppl ied t ubing. Refer to T able 4 for th e co rrect line sizes. 2. Do not us e l es s t han 10 ft (93.
13 ! W ARNING ELECTRICAL SHOCK HAZARD Fai lure to fol low thi s wa rni ng could r es ult i n pe rs onal inj ury or death . Bef ore per form ing se rvic e or mai nte nanc e, be s ure indoor uni t ma in powe r s wit ch i s t urned O FF and i ndoor blow er ha s st opped.
14 ELECTRICAL DA T A T ab le 10 – 3 8 HD R Electrica l Data 38HD R UNIT S IZE V --- P H --- H z VOL T AG E RANGE* CO MP RESSOR OUTDOOR F AN MOTOR MIN C KT AMPS FUSE/ HA CR BKR AMPS Min Max RLA LRA FLA NEC H p kW Out 018 208/230 - - - 1 - - - 60 187 253 9.
15 A09597 Fig. 20 - - 38HDR and 40QA C Cooli ng Syste m W ir ing Diagr am 40QAC/ 38HDR - - 40QAQ/38QR R.
16 A09598 Fig. 21 - - 38QRR and 40QAQ H eat Pump Sys te m W iri ng Diagr am 40QAC/ 38HDR - - 40QAQ/38QR R.
17 Com plete Indo or Piping The pipi ng to the i ndoor unit c an be rout ed fr om the bac k, side and top. I f the uni t is be ing pipe d fr om the t op or the side s ee note bel ow . 1. On he at 40QAQ024 – 048, the c ooling pis ton (i ndoor) i s ship p ed in the factory in stalled metering d ev ice w ith the in- door uni t.
18 Com p let e Contr ol Wir ing 1. Ru n th e co ntro l w iring clo se to the termin al blo ck o n th e indoor uni t. 2. Connec t t he wir es as shown in F ig 18 and Fi g.
19 HP ONL Y COOLING ONL Y A09545 Fig. 25 - - Therm ost at Wi r e Connec tion for 40QA C Heating Only Fig. 26 - - Therm ost at Wi r e Connec tion for 40QA Q Reasse mble In door Unit 1. Rein stall filters an d in let g rilles 2. Reins tal l the si de panel s ST AR T - - UP Pr eliminar y Checks 1.
20 Manifold Gage 500 microns Low side valve High side valve Charge hose Charge hose V acuum pump Low side valve A07361 Fig. 29 - - Mani fol d Deep V a cu u m Met hod The de ep va cuum m et hod requi r.
21 OPERA TING SEQUENCE Ceilin g - - susp end ed fan co il units hav e a relay bo ard wh ich contro ls sys te m ope ra tion i n res ponse to a room the rmos ta t. The us er ma y ma nual ly se le ct any one of 3 fa n spee ds f or uni t oper at ion. The dis cha r ge louve rs on t he unit c an be s ta tiona ry or s wing cont inuousl y .
22 T able 13 – Cl eaning and M aint enance Sche dule TA SK MO NTHL Y QUARTERL Y YEARL Y INDOOR UN IT Clea n Air F ilt ers X Clea n Dr ain P ipe X Clea n Conden sate Dr ain P an X Clea n Ind oor Coil.
23 Befor e Calling f or Serv ice Save t he cos t of a se rvic e cal l by doing the fol lowi ng: 1. Be sure main p ow er to system is turned o n . 2. Pres s Mode butt on until OF F is dis playe d. W a it 5 minut es. 3. Pres s Mode butt o n until ei ther COO L or HEA T is dis playe d (as desired ).
24 LEGEND NOTE: F or syst em s wit h i ndoor units equipped with mic ropr oces s or contr ol, s ee separ ate contr ols, serv ic e, and troubles hooting manual.
25 LEGEND NO TE: For systems with indoor units equipped with microprocessor control, see se p arate controls, service, and troubleshootin g manual. NC — Norm ally Closed ODT — O utdoor Ther mostat A07436 Fig.
26 Copyright 2009 Carrier Corp. S 7310 W . Morris St. S I ndianapolis , IN 46231 Print ed in U.S .A. Edition Date: 10/09 Manufacturer reser ves the right to change , at any time, specifications and designs without notice and without oblig ations.
Ein wichtiger Punkt beim Kauf des Geräts Carrier 40QAC (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Carrier 40QAC noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Carrier 40QAC - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Carrier 40QAC reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Carrier 40QAC erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Carrier 40QAC besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Carrier 40QAC verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Carrier 40QAC. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Carrier 40QAC gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.