Benutzeranleitung / Produktwartung 38VYX130 des Produzenten Carrier
Zur Seite of 14
38VYX110/38VYX130 • L L O Y D ' S R E G I S T E R Q U A L I T Y A S S U R A N C E I S O 9 0 0 1 INST ALLA TION MANU AL.
38VYX110/38VYX130 Heat pump split system outdoor units GB - 1 ENGLISH For operation and maintenance instructions of this unit as well as installation instructions of the indoor unit, refer to the rele vant man uals. Contents P age Precautions f or safety .
GB - 2 38VYX110/38VYX130 General inf ormation Precautions f or safety The unit m ust be installed according to the national plant- engineering standards. • Read this “ PRECA UTIONS FOR SAFETY ” carefully bef ore Installation. • The precautions described below include the impor tant items regarding saf ety .
GB - 3 38VYX110/38VYX130 ENGLISH Outdoor unit Drain nipple Installation manual x 1 W ater proof rubber cap Accessory and refrig erant T ab le II: Accessory and Installation P ar ts Refrigerant Piping • Piping kit used f or the conventional refrigerant cannot be used.
GB - 4 38VYX110/38VYX130 Knock out procedure • The indoor/outdoor connecting pipes can be connected to 4 directions. T ake off the knoc kout part of the pipe cover in which pipes or wires pass through the base plate. • As shown in the figure , do not remove the pipe co ver from the cabinet so that the knock out hole can be easily punched.
GB - 5 38VYX110/38VYX130 ENGLISH Refrigerant piping Flaring 1. Cut the pipe with a pipe cutter . 2. Inser t a flare nut into the pipe, and flare the pipe. As the flaring sizes of R410A diff er from those of refrigerant R22, the flare tools newly man ufactured f or R410A are recommended.
38VYX110/38VYX130 GB - 6 Minim um clearances Single unit installation Obstac les at both right and left sides. Serial installation of two or more units Single unit installation Obstac les at both right and left sides. 1000 or more 1000 or more • The height of the obstacle should be low er than the height of the outdoor unit.
GB - 7 38VYX110/38VYX130 ENGLISH Minim um clearances Open the upper side and both right and left sides. The height of obstacle at both front and rear side, should be low er than the height of the outdoor unit.
GB - 8 38VYX110/38VYX130 • When there is a possibility of freezing of drain at the cold district or a snowf all area, be careful for dr ainage ability of drain. The drainage ability increases when a knock out hole on the base plate is opened. (Open the knockout hole to outside using a screwdriv er , etc.
GB - 9 38VYX110/38VYX130 ENGLISH Ev acuating Air Purge With respect to the preser vation of terrestrial environment, adopt “ V acuum pump ” for air purge (Ev acuate air in the connecting pipes) when installing the unit. • Do not discharge the refrigerant gas to the atmosphere to preser ve the terrestrial environment.
38VYX110/38VYX130 GB - 10 All field electrical connections are the responsibility of the installer . W ARNING: • Wrong wiring ma y cause a burn-out to some electr ical par ts.
GB - 11 38VYX110/38VYX130 ENGLISH Final installation chec ks Check and T est Operation For R410A, use the leak detector e xclusively manuf actured for HFC refrigerant (R410A, R134a, etc.). • The conv entional leak detector for HCFC refrigerant (R22, etc.
38VYX110/38VYX130 GB - 12 Final installation chec ks Installation/Servicing T ools Changes in the product and components In the case of an air conditioner using R410A, in order to prev ent any other refrigerant from being charged accidentally , ser vice por t diameter of the outdoor unit control valv e (3 way v alve) has been changed.
38VYX 110-130 Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1 The manufacturer reserves the right to change an y product specifications without notice.
Ein wichtiger Punkt beim Kauf des Geräts Carrier 38VYX130 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Carrier 38VYX130 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Carrier 38VYX130 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Carrier 38VYX130 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Carrier 38VYX130 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Carrier 38VYX130 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Carrier 38VYX130 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Carrier 38VYX130. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Carrier 38VYX130 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.