Benutzeranleitung / Produktwartung EKI-2741SX des Produzenten Advantech
Zur Seite of 32
EKI-2741F 10/100/1000Bas e-T to SFP (mini-GBIC) Type Fiber Optic Media Converter EKI-2741SX 10/100/1000Bas e-T to 1000Base-SX SC Type Fiber Optic Media Converter EKI-2741LX 10/100/1000Bas e-T to 1000B.
EKI-2741F-SX-LX User Manual ii Copyright The documentation and the software i ncluded wi th this product are copyrighted 2007 by Advantech Co., Ltd. All rights ar e reserved. Advantech Co., Ltd. reserves the right to mak e improvements in the pro ducts describe d in this ma nual at any time without noti ce.
iii Product Warranty (2 years) Advantech warrants to you, the or igina l purchaser, that each of its products will be fre e from defects in materials and workmanshi p for two years from the date of purchase.
EKI-2741F-SX-LX User Manual iv Declaration of Conformity CE This product has passed the CE test for envir onmental spe cifications. Test conditions for passing included the equipment being operated within an indust rial enclosure.
v Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC out let before clea ning. Use a damp cloth. Do not use liquid or spray detergents for clean ing.
EKI-2741F-SX-LX User Manual vi Safety Precaution - Static Electricity Follow these simple precautions to protect your self from harm and the produ cts from damage. 1. To avoid electrical shock, always di sconnec t the power from your PC chassis before you work on it.
vii Contents Contents Chapter 1 Overview ........................................... 2 1.1 Introduction ......................................................... 2 1.1.1 Fast Fiber Converters Module ................... 2 1.1.2 Dual Power Input .......
EKI-2741F-SX-LX User Manual viii.
1 Chapter1 Overview Sections include: z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER.
EKI-2741F-SX-LX User Manual 2 Chapter 1 Overview 1.1 Introduction The EKI-2741 is designed to convert Gi gabit Ethernet networks to Gigabit fiber networks by transparently converting Ethern e t signals to optic sig nals. The advantages of fiber optics are wide bandwidth, EMI immunity and long-distan ce transmission capability.
3 Chapter1 1.2 Features • Provides 1 x SFP (mini-GBIC) type connector (EKI-2741F) • Provides 1 x 1000Base-SX or 1000Base-LX SC type connector (E KI-2741SX/LX) • Provides 1 x 10/100/1000Mbps Ethe.
EKI-2741F-SX-LX User Manual 4 1.3 Specification Communications Standard IEEE 802.3, 802.3ab, 802.3u, 802.3x, 802.3z LAN 10/100/1000Base-TX, 1000Base -SX, 1000Base-LX Transmission Distance Multi-Mode F.
5 Chapter1 Environment Operating Temperature -10 ~ 60 ℃ (14~140 ℉ ) Wide temp. model: -40 ~ 75 ℃ (-40 ~ 167℉) Storage Temperature -40 ~ 85 ℃ (-40 ~ 185 ℉ ) Operating Humidity 5 ~ 95% (non-conde nsing) Storage Humidity 0 ~ 95% (non-condensi ng) Certifications Safety UL, 60950-1, CAN/CSA-C22.
EKI-2741F-SX-LX User Manual 6 1.4 Packing List • 1 x EKI-2741F or EKI-2741SX or EKI -2741LX Industrial Ethernet Switch • 1 x eAutomation Industrial Communication CD-ROM with software, and User m a.
7 Chapter2 Installation Sections include: z LED Indicators z Dimensions z Mounting z Network Connection z Power Connection CHAPTER.
EKI-2741F-SX-LX User Manual 8 Chapter 2 Installation In this chapter, you will be given an over view of the EKI-2741F/SX/LX hardware installation procedures.
9 Chapter2 2.2 DIP-Switch The DIP-Switch is used to config ure operation mode for LFP ( Link Fault Pass- Through ) and operation mode for UT P/Fiber port.
EKI-2741F-SX-LX User Manual 10 2.3 Dimensions (units: mm) Figure 2.1: Front View of EKI-2741 series.
11 Ch apter2 Figure 2.2: Side View of EKI-2741 series.
EKI-2741F-SX-LX User Manual 12 Figure 2.3: Rear View of EKI-2741 series.
13 Ch apter2 The terminal block of power & relay is located o n the top side. Please refer to page 16 for pin assignment. Figure 2.4: Top View of EKI-2741 series.
EKI-2741F-SX-LX User Manual 14 2.4 Mounting The EKI-2741F/SX/LX support two mounting methods: DIN-rail & Wall. 2.4.1 Wall mounting EKI-2741F/SX/LX can be wall-mounted by using the included mou nting kit. Then, hang on the EKI-2741F/SX/LX to the nails on the wall.
15 Ch apter2 2.4.2 DIN-rail Mounting You can also mount EKI-2741F/SX/LX on a standard DIN-rail by below steps. The DIN-rail kit is screwed on the industrial sw itch when out of factory. If the DIN-rail kit is not screwed on the industrial switch, please screw the DIN-rail kit on the switch first.
EKI-2741F-SX-LX User Manual 16 Then, let the device down straight to slide over the rail smoothly. See Figure 2.7 Figure 2.7: Installation to DIN-rail Step 2.
17 Ch apter2 2.5 Network Connection • Twisted-pair segment can use unshielded tw isted pair (UTP) or shi elded twisted pair (STP) cabling. The cable between the lin k pa rtner (switch, hub, workstation, etc.) and the converter, mu st be less than 100 meters (328 ft.
EKI-2741F-SX-LX User Manual 18 Second, insert the fiber cable of LC conn ector into the transceiver. Figure 2.10: LC connector to the transceiver To remove the LC connector from the trans ceiver, please follow the step s shown below: First, press the upper side of the LC con nector fr om the transceiver and pull it out to release.
19 Ch apter2 Second, push down the metal loop and pull the transceiver out by the plastic part. Figure 2.12: Pull out from the SFP module.
EKI-2741F-SX-LX User Manual 20 2.6 Power Connection The EKI-2741F/SX/LX support dual +12 ~ 48 V DC power inputs a nd power-fail relay output. Figure 2.13: Pin Assignment of the Power Connecto r You can connect an alarm i ndicator, buzzer or other signalin g equipment through the relay output.
21 Ch apter2 Troubleshooting CHAPTER.
EKI-2741F-SX-LX User Manual 22 Chapter 3 Troubleshooting 1. Power Input Verify that is using the right power cord/ada pter (+12~48 V DC ), please don’t use the power adaptor with DC o utput voltage higher than 48V, or it will burn this converter down.
23 Ch apter2 Pin Assignment & Wiring APPENDIX.
EKI-2741F-SX-LX User Manual 24 Appendix A Pin Assignment & Wiring It is suggested to adopt ELA/TIA as the wiring of the RJ-45. Figure A.1: RJ-45 Pin Assignment Figure A.
Ein wichtiger Punkt beim Kauf des Geräts Advantech EKI-2741SX (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Advantech EKI-2741SX noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Advantech EKI-2741SX - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Advantech EKI-2741SX reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Advantech EKI-2741SX erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Advantech EKI-2741SX besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Advantech EKI-2741SX verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Advantech EKI-2741SX. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Advantech EKI-2741SX gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.