Benutzeranleitung / Produktwartung QL des Produzenten Cannon
Zur Seite of 24
Canon Pellix Camera Manual posted 4-28-'03 For reference use on many Cannon manual focus and metering cameras . This camera manual library is for reference and historical purposes, all rights reserved. This page is copyright by mike@butkus.org, M.
Contents Mercury Battery Loading : 8 Film Winding : 10 Shutter and Aperture Adjustment : 12 How to Use Built-in Exposure Meter : 16 Exposure Setting 1--Shutter Speed Priority Method : 18 Exposure Sett.
Technical Data Type: 35mm single-lens reflex camera. Viewfinder: Eye-level system using pentagonal prism. Waist Level Viewer 2 can be attached. Focusing Glass: Highly efficient in resolving power, using Fresnel lens and built in prism screen rangefinder.
.
Mercury Battery Loading Load the mercury battery into the battery compartment. The mercury battery powers the built in CdS exposure meter, and the meter will not function unless the battery is in position. 1. Press the finger against the battery cover and turn to the left to remove.
Film Winding 1. The turning of the film advance lever cocks the shutter, film winding and aperture charging in one motion. 2. When the shutter button is pressed, the diaphragm simultaneously closes down to the pre-selected F stop and the shutter operates.
Shutter and Aperture Adjustment The shutter and aperture adjust the exposure with the shutter adjusting the exposure time and the aperture ad lusting the amount of light. The Canon PELLIX QL uses the zero-method coupled meter, and it is very simple to get the proper exposure.
è The aperture ring can also be set to intermediate values. è Depending on the lens, there are instances where there is no relation to the lightness being halved between the maximum diameter of the aperture and the next aperture reading.
How to Use Built in Exposure Meter The exposure meter of the PELLIX QL, which is of the zero method type, is coupled to the shutter dial and aperture ring. The exact exposure is easily determined according to the brightness of the subject to be photographed.
(1000) (1250) (2000) 800. · 1600. 30. · 33. (31) (32) (34) Figures in parentheses represent intermediate film speeds. è The film speeds are shown either on the film box cover or on the explanatory sheet. CdS Actuating Lever The exposure meter can be set into measuring condition by turning the CdS actuating lever towards the lens.
è Canon's TTLM system has been adopted in the PELLIX QL which provides the most accurate photometry. Under this system, the CdS photocell of the built-in meter is placed in the closest position to the film on the back side of the panicle mirror.
Focusing While looking through the viewfinder, rotate the focusing ring. It is out of focus when the image within the circle in the center of the viewfinder is unclear.
è Eyesight adjustment lenses are available as optional attachment. When an eyesight adjustment lens is attached to the eyepiece, those who are far-sighted or near-sighted can take pictures without glasses. Four different Copters of +1.5, 0, -2.5, and -4 are available.
2. Stabilize the camera by pressing it C against the cheek or forehead. 3. When the camera is in a horizontal position, both elbows should be firmly pressed against the body, and at least one elbow should be resting against the body when in a vertical position.
Film Loading Canon PELLIX QL accepts any standard 35mm film in cartridge for daylight loading. è When loading a new film, avoid direct sunlight. 4 When repacking a long-wound film for darkroom loading into the ordinary cartridge, trim the end of the leader part in between the perforations.
Fold down the rewinding crank. è If the film is sagging, the cartridge will rise and the back cover will not close. 6. Make three blank shots. Leave the lens cap on and advance the film three times, each time releasing the shutter. The film counter will advance from the "S" mark to "O".
become impossible. If this happens, open the back cover in a completely dark room. Photography Using Self-timer and Eyepiece Shutter Wind the shutter and close the eyepiece shutter. Turn the self-timer lever in the direction of the arrow and press the shutter button.
Uses of Lenses Changing Lenses In removing the lens from the camera, after turning the bayonet ring of the lens to the left, take out the lens. In mounting the lens, match the red dot of the lens to the red dot on the camera mount Turn the bayonet ring to the right and fasten.
Film Plane Mark The lens distance index is scaled by measuring the distance from the film position. Thus, in case the focusing is done by actual measurement, measure from the film plane mark and transfer this distance to the lens distance index. www.4.
pictures must be taken with the manual aperture. Double Exposure Under ordinary usage, there is no danger of double exposure. However, double exposure can be made by the following steps: 1. When the first exposure has been made, press the rewinding button.
Proper Care of the Canon PELLIX QL Storage of Camera Moisture and dust are harmful to your camera. It should be taken out into the fresh air from time to time. If your camera is to be stored for a long time, it should be removed from its case. Silica gel or another drying agent should be placed alongside it.
Interchangeable Lenses and Accessories A wide range of interchangeable lenses from 19mm to 1000mm and various accessories are available to further enhance your PELLIX QL. Canon Interchangeable Lenses FL 19mm F 3.5R FL 100mm F 3.5 FL 28mm F 3.5 FL 135mm F 2.
Canon Booster A separately available Canon Booster is an auxiliary meter that is attached to the PELLIX QL and FT QL for measuring the subjects under dim lighting conditions. Technical Data Light Measuring Range: Using ASA 100 film EV 1.5 1/2sec. - EV-4.
· Bellows FL · Photomicro Unit F · Canon Booster · Copy Stand 3F · Handy Stand F · 58mm Close-up Lens 240, 450, 1800 · Camera Holder R4-2.
Ein wichtiger Punkt beim Kauf des Geräts Cannon QL (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cannon QL noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cannon QL - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cannon QL reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cannon QL erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cannon QL besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cannon QL verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cannon QL. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cannon QL gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.