Section 61102040L4-5, Issue 2 61102040L4-5B 1 1. GENERAL This practice provides installation and maintenance information for the ADTRAN SLC-5 U-BR1TE III w/ PWR and DDS Loopbacks (U-BR1TE III).
Section 61102040L4-5, Issue 2 61102040L4-5B 2 • Loopback release in response to TIPs generated from the network direction per TR62310. • Remap all subsequent DS0 DP loopback codes into respective eoc loopbacks to loopback respective downstream U-Repeaters, TRISDN elements, and U-BR1TES when optioned for 1B+D, or 2B+D.
Section 61102040L4-5, Issue 2 61102040L4-5B 3 C A U T I O N C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. The U-BR1TE III will function with any ISDN 2B1Q U-interface that is ANSI T1.601 compliant.
Section 61102040L4-5, Issue 2 61102040L4-5B 4 NOTE When the U-BR1TE III is optioned for B1 or B2, the SLC-2000 slot must be provisioned for D only. If the U-BR1TE III is optioned for 2B, then the SLC-2000 slot must be provisioned for B1+D. Physical Requirements The U-BR1TE III occupies one physical slot in the SLC-5 or SLC-2000 channel bank.
Section 61102040L4-5, Issue 2 61102040L4-5B 5 e p y T e c i v r e S e c i v r e S n o i t p On o i t p O n o i t p O n o i t p On o i t p O 1 - 1 W S ) 1 B () 1 B ( ) 1 B ( ) 1 B () 1 B ( 2 - 1 W S ) .
Section 61102040L4-5, Issue 2 61102040L4-5B 6 Figure 5 displays the position switch settings at ISDN network locations. Figure 5. Position Switch Settings at Network Locations for ISDN Applications 2-.
Section 61102040L4-5, Issue 2 61102040L4-5B 7 Figure 6. SLC-5 U-BR1TE III IDSL/DDS Circuit Diagram 4W DS0 DP or OCU DP T1 T1 D4 AB C D E D4 RT 4W DS0 DP or DCS 2-Wire Local Loop 2-Wire Local Loop 4W D.
Section 61102040L4-5, Issue 2 61102040L4-5B 8 Front Panel Features The RJ-45 jack allows front panel test access for local or downstream loopbacks. The address select knob (SW3) determines which element is being looped back. Table 3 lists the loopback options.
Section 61102040L4-5, Issue 2 61102040L4-5B 9 To initiate a point-to-point test, perform the following: 1. Connect the DS0 digital tester to the RJ-45 jack. 2. Configure the test set for Near Logic and 64kbps. 3. Select the desired test direction and bearer channel using the address select knob.
Section 61102040L4-5, Issue 2 61102040L4-5B 10 When the U-BR1TE III operation is normal, the ADR7 position of SW1 does not have a function. NOTE This test option is only available on power up of the U-BR1TE III.
Section 61102040L4-5, Issue 2 61102040L4-5B 11 DS0 DP Loopback eoc Remapping Upon receipt of subsequent DS0 DP loopback codes when the D channel is disabled, the U-BR1TE III remaps the subsequent DS0 DP loopback sequences into the respective ISDN eoc loopback messages.
Section 61102040L4-5, Issue 2 61102040L4-5B 12 Remote End Initiated LBK Tests The U-BR1TE supports loopbacks generated from the IDSL OCU-R which allow testing to be performed without coordination with the CO or test center.
Section 61102040L4-5, Issue 2 61102040L4-5B 13 Figure 11. IDSL/DDS Trouble Codes MOS 9Ah Channel Bank Open 2-wire Loop DSU IDSL OCU-R U-BR1TE Customer Premises ASC 9Eh Channel Bank ASC 9Eh Open 4-Wire.
Section 61102040L4-5, Issue 2 61102040L4-5B 14.
Ein wichtiger Punkt beim Kauf des Geräts ADTRAN SLC-5 U-BR1TE III (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie ADTRAN SLC-5 U-BR1TE III noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für ADTRAN SLC-5 U-BR1TE III - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von ADTRAN SLC-5 U-BR1TE III reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über ADTRAN SLC-5 U-BR1TE III erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon ADTRAN SLC-5 U-BR1TE III besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von ADTRAN SLC-5 U-BR1TE III verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit ADTRAN SLC-5 U-BR1TE III. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei ADTRAN SLC-5 U-BR1TE III gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.