Benutzeranleitung / Produktwartung MONO CLASS D des Produzenten Cadence
Zur Seite of 16
MONO CLASS D AMPLIFIERS.
INTRODUCTION 2 Thank you for purchasing a Cadence T ype RS amplifier . Over the past years, the technology used to create audio amplifiers has grown by leaps and bounds. W e have thousands of satisfied customers still using our first generation Ultra Drive amplifiers which are almost 10 years old.
FEA TURES 3 GOLD PLA TED TERMINALS: BASS DRIVE EQUALIZA TION CIRCUITRY : “ADR”: - ACTIVE DYNAMIC REGULA TION CLASS D AUDIO ST AGE PERFORMANCE POWER AND PROTECTION CIRCUITR Y : STIFFENING CAP ACITO.
FEA TURES 4 “ARV A” - AUTOMA TIC RAIL VOL T AGE ADJUSTMENT CIRCUITR Y : AMPLIFIER MODE SWITCH BA TTERY VOL T AGE: INDUCTION AND TUNNEL F AN COOLING: PROTECTION CIRCUITR Y : Cadence RS amplifiers feature "ARV A" circuitry in their power supply .
INST ALLA TION BASICS 5 INST ALLA TION BASICS: REMOTE TURN ON CONECTION: STIFFENING CAP ACITOR DIRECT CONNECTION: USING THE RS AMPLIFIERS IN CONJUNCTION WITH A MUL TI- CHANNEL AMPLIFIER: POWER/GROUND WIRING: Before you begin with your installation disconnect the NEGA TIVE (-) terminal from your car's battery .
MOUNTING 6 MOUNTING THE RS AMPLIFIERS: 1 A B A 2 3 Choose a convenient mounting location with unobstructed airflow . 1 - Mount and fasten amplifier bracket A onto the mounting surface, with two screws as shown. 2 - Slide the amplifier so that hook B engages with bracket A.
Remote turn on Remote turn on Mode switch Line level inputs from head unit S tereo RCA cable from RS LINE OUT to highs amp LINE IN CPR Remote Control Woofer 1 ohm minimum High frequency speakers Groun.
USING THE CPR REMOTE CONTROL WITH THE RS AMPLIFIERS 8 CPR (COMPETITION PODIUM REMOTE) BASICS LEVEL CONTROL: BURST BUTTON: DIGIT AL BA TTERY VOL T AGE MONITOR: POWER BARGRAPH: INST ALLA TION: The optional CPR remote control can be used for street or SPL competitions alike.
ADJUSTING THE SYSTEM 9 SETTING THE TOP P ANEL CONTROLS ADJUSTING THE SYSTEM AUDIO PREAMP INPUT AUDIO PREAMP OUTPUT USING THE BUIL T-IN LOW P ASS ELECTRONIC CROSSOVER SUBSONIC FIL TERING . PHASE SHIFT CONTROL AMPLIFIER MODE SWITCH The RS amplifiers feature RCA preamp inputs.
MASTER/SLA VE CONNECTION DIAGRAM MONO BRIDGING 2 AMPLIFIERS INTO 1 WOOFER 10 Mode switch Mode switch 2 ohm minimum AMPLIFIER MODE SWITCH, INPUTS AND REMOTE CONTROL Set the AMPLIFIER MODE switches as shown Connect the source to the master amplifier inputs, and an optional CPR remote control to the master , as shown.
MONO BRIDGING MUL TIPLE P AIRS OF AMPLIFIERS 2 OR MORE AMPLIFIERS WITH SEP ARA TE SPEAKERS IMPORT ANT : Note the reverse speaker phase on 2nd amplifier IMPORT ANT : Reverse the speaker phase on every .
BASIC SPEAKER WIRING DIAGRAMS FOR V ARIOUS LOADS 12 4 OHM 8 OHM 2 OHM 4 OHM 1 OHM TO AMPLIFIER 2 OHM TO AMPLIFIER 4 OHM TO AMPLIFIER 8 OHM TO AMPLIFIER 1 OHM TO AMPLIFIER 2 OHM TO AMPLIFIER + + + + + .
ADV ANCED SPEAKER WIRING DIAGRAMS FOR V ARIOUS LOADS 13 P ARALLEL: DUAL VOICE COIL SPEAKERS 3 X DUAL VC 8 OHM SPEAKERS WITH P ARALLEL VOICE COILS, IN P ARALLEL 2 X DUAL VC 4 OHM SPEAKERS WITH P ARALLE.
TROUBLESHOOTING 14 GENERAL TOOLS NEEDED NO SOUND By utilizing this process of elimination you can determine where the cause of the problem is. If the amplifier goes in to diagnostic with nothing connected to it, and you are sure of proper power and ground, please contact our service dep artment for further help ay 732 370 5400.
SPECIFICA TIONS 15 Due to constant product improvements, these specifications are subject to change without notice. High current rated powers are at amplifier minimum distortion and are for competition purposes. Not responsible for typographical errors.
MONO CLASS D AMPLIFIERS.
Ein wichtiger Punkt beim Kauf des Geräts Cadence MONO CLASS D (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cadence MONO CLASS D noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cadence MONO CLASS D - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cadence MONO CLASS D reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cadence MONO CLASS D erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cadence MONO CLASS D besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cadence MONO CLASS D verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cadence MONO CLASS D. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cadence MONO CLASS D gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.