Benutzeranleitung / Produktwartung FOT-F3 des Produzenten Cabletron Systems
Zur Seite of 41
FOT-F3 FIBER OPTIC TRANSCEIVER USER’S MANUAL CABLETRON SYSTEMS, P.O. BOX 5005, Rochester, NH 03867- 0505.
NOTICE i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
FCC NOTICE ii FCC NOTICE This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
iii CONTENTS CONTENTS CHAPTER PAGE CHAPTER 1 INTRODUCTION 1.1 Using This Manual .................................................. 1-1 1.2 Getting Help ............................................................ 1-2 1.3 The FOT-F3 Fiber Optic Transceiver .
iv CONTENTS CHAPTER 3 (Cont.) 3.3 Mounting the FOT-F3 ............................................. 3-8 3.4 Cable Support Installation ....................................... 3-9 CHAPTER 4 TESTING AND USING LANVIEW 4.1 Installation Checkout ..........
Page 1 - 1 INTRODUCTION CHAPTER 1 INTRODUCTION Welcome to Cabletron Systems’ FOT-F3 Fiber Optic Transceiver User’s Manual . We have designed this manual to serve as a simple installation and reference guide for the Cabletron Systems FOT-F3 transceiver.
Page 1 - 2 INTRODUCTION Chapter 2, Installation Requirements/Specifications , contains a list of hardware, software, location and environmental requirements that must be met before you install the FOT-F3. A list of FOT-F3 specifications is also provided.
Page 1 - 3 INTRODUCTION manual, feel free to contact Cabletron Systems’ Technical Support at: Cabletron Systems P.O. Box 5005 Rochester, NH 03867-0505 Phone: (603) 332-9400 1.3 THE FOT-F3 FIBER OPTIC TRANSCEIVER Connections The Cabletron Systems FOT-F3 Fiber Optic Transceiver (Fiber Optic Medium Attachment Unit or FOMAU) (Fig.
Page 1 - 4 INTRODUCTION Figure 1-1. FOT-F3 A fiber optic cable is connected to the transceiver through ST fiber optic ports on the FOT-F3. This provides an optical link to connect the device to the network. The fiber optic link segment can run from the FOT-F3 to any Ethernet FOIRL compatible fiber optic device.
Page 1 - 5 INTRODUCTION An AUI cable, up to 50 meters long, is used to connect an Ethernet device to the AUI port on the transceiver. The AUI cable must meet specifications for either IEEE 802.
Page 1 - 6 INTRODUCTION Application The FOT-F3 can be configured into your network in many ways. For example, a fiber optic link segment (4, Fig. 1-2) can be attached to a Cabletron Systems’ Multi Media Access Center (MMAC ) (5) with a FOMIM-32/36/38.
Page 1 - 7 INTRODUCTION In another example, an FOT-F3 (3, Fig. 1-3) is connected to an MMAC (1) by an AUI cable (2) attached to an Intelligent Repeater Module (IRM ) in the MMAC. A lengthy fiber optic link segment (4), up to ten kilometers, runs from the FOT-F3 and to a Cabletron Systems’ NB25 bridge (7).
Page 1 - 8 INTRODUCTION 1.4 RELATED MANUALS The manuals identified below should be used to supplement the procedures and other technical data provided in this manual. The procedures contained in the manuals below will be referenced only. Cabletron Systems’ LAN-MD Portable Ethernet Tester User’s Manual.
Page 2 - 1 REQUIREMENTS/SPECS. CHAPTER 2 INSTALLATION REQUIREMENTS/ SPECIFICATIONS Before you attempt to install Cabletron Systems’ FOT-F3 Fiber Optic Transceiver, review the network design guidelines outlined in this chapter. In addition, you should review the operating specifications and environmental requirements which are also listed.
Page 2 - 2 REQUIREMENTS/SPECS. 2.1.1 Fiber Optic Requirements • The fiber optic link segments should consist of single mode 8/125 - 12/125 µ m fiber optic cabling. You can also use multi mode 62.5/125 µ m fiber optic cabling, but signal distance will be much shorter (about 2 km).
Page 2 - 3 REQUIREMENTS/SPECS. 2.1.2 AUI Requirements • The AUI cable connecting the transceiver to a device must be Ethernet Version 1, Version 2, and/or IEEE 802.3 type cables that match the type of device being attached to the AUI port. • The AUI cable must not exceed 50 meters (164 feet) in length.
Page 2 - 4 REQUIREMENTS/SPECS. FIBER OPTIC INTERFACE Type: FOT-F3: ST fiber optic ports. Parameter Typical Minimum Maximum Receive -31.0 dBm -33.5 dBm -29.5 dBm Sensitivity: Max. Receive Input Power: -7.5 dBm -9.72 dBm -6.99 dBm Transmitter Power at 25 ° C Into 8.
Page 2 - 5 REQUIREMENTS/SPECS. FIBER OPTIC INTERFACE (cont.) Transmitter Peak 1300 nm 1270 nm 1330 nm Wave Length Spectral Width 60 nm - 100 nm Rise Time/ 3.
Page 2 - 6 REQUIREMENTS/SPECS. AUI CONNECTOR Type: 15 position D type receptacle (Fig. 2-1) Pin 1 Logic Ref. Pin 9 Collision - 2 Collision + 10 Transmit - 3 Transmit + 11 Logic Ref. 4 Logic Ref. 12 Receive - 5 Receive + 13 Power (+12 Vdc) 6 Power Return 14 Logic Ref.
Page 2 - 7 REQUIREMENTS/SPECS. INDICATORS NOTE : The FOT-F3 has six LEDs (Fig. 2-2), which are explained in detail in Chapter 4, Testing and LANVIEW . PWR (Power) When lit, this LED indicates that the FOT-F3 is receiving power (green indicator). SQE (Signal test Quality Error) When lit, this LED indicates that SQE is enabled (yellow indicator).
Page 2 - 8 REQUIREMENTS/SPECS. INDICATORS (cont.) XMT (Transmit) This LED flashes to indicate that the FOT-F3 is transmitting packets onto the network (green indicator). RCV (Receive) This LED flashes to indicate that the FOT-F3 is receiving data packets from the network (yellow indicator).
Page 2 - 9 REQUIREMENTS/SPECS. ENVIRONMENTAL Operating Temperature: 5 ° to 55 ° C Operating Humidity: 5 to 95% (non-condensing) SAFETY Designed in accordance with UL478, UL910, NEC 725-2(b), CSA, IEC, TUV, VDE class A. Meets FCC, Part 15, Class A limits.
Page 3 - 1 INSTALLATION CHAPTER 3 INSTALLING THE FOT-F3 This chapter contains instructions for unpacking your Cabletron Systems’ FOT-F3 Transceiver, connecting the FOT-F3 to an Ethernet device and the network, installing cable supports, and mounting the transceiver (if necessary).
Page 3 - 2 INSTALLATION • One set of Velcro mounts • Two cable mounts (for strain relief) • Two cable ties (0.1 x 4 inches). If you notice any discrepancies, contact Cabletron Systems’ Technical Support immediately.
Page 3 - 3 INSTALLATION NOTE: The SQE test function must be disabled if you are connecting the transceiver to Ethernet Version 1 equipment or to a repeater. Set the SQE Switch as follows: • To disable the SQE test function, set the switch (Fig. 3-1) towards the optical ports to the off (o) setting.
Page 3 - 4 INSTALLATION 3.2.2 Connecting the AUI Cable To connect your Ethernet device to the FOT-F3, attach an AUI cable as follows. See Figure 3-2. 1. Attach an AUI cable to the device to which the FOT-F3 will be connected. 2. Attach the female connector on the AUI cable to the AUI port on the FOT-F3.
Page 3 - 5 INSTALLATION If the PWR LED is not lit, perform the following steps: a. Verify that the power is turned on for the device attached to the FOT-F3. b. Disconnect the AUI from the FOT-F3. c. Disconnect the device to which the transceiver is attached.
Page 3 - 6 INSTALLATION NOTE: We recommend labeling the fiber optic cable to indicate which fiber is Receive and which is Transmit. When you buy fiber optic cable from Cabletron Systems, at one end of the cable, one fiber is labeled 1, and the other fiber is labeled 2.
Page 3 - 7 INSTALLATION Figure 3-3. ST Connectors 2. Attach the fiber labeled 1 to the bottom port, labeled RX on the FOT-F3. 3. Attach the fiber labeled 2 to the top port, labeled TX . 4. At the other end of the fiber optic cable, attach the fiber labeled 1 to the transmit port of the device.
Page 3 - 8 INSTALLATION 6. Check that the LNK LED on the FOT-F3 is lit. If the LED is not lit, perform each of the following steps until the LED is lit: a. Check that the power is on for the device at the other end of the link. b. Verify that the fiber strands are properly connected to each port.
Page 3 - 9 INSTALLATION • Allows the AUI cable to be easily connected from the transceiver to the workstation. • Has a smooth, dirt-free surface which will easily accept the adhesive bonds. Mount the FOT-F3 as follows: 1. Separate the two 1.5" x 3" Velcro mounts.
Page 3 - 10 INSTALLATION NOTE: Be sure each cable is securely attached to its port and that the slide latch on the AUI connector is secured to the lock posts on the AUI port. See Figure 3-2. To strain relief the cables for a wall-mounted FOT-F3 (Fig. 3-4): 1.
Page 3 - 11 INSTALLATION Figure 3-4. Mounting the FOT-F3 DEVICE FOT-F3 Tie Wraps Fiber Optic Segment Cable Mounts AUI Cable.
Page 4 - 1 TESTING AND TROUBLESHOOTING CHAPTER 4 TESTING AND TROUBLESHOOTING This chapter lists procedures to test the FOT-F3 Fiber Optic Transceiver after it has been connected to the network. A description of LANVIEW and its function in troubleshooting physical layer network problems are also given.
Page 4 - 2 TESTING AND TROUBLESHOOTING 4.1.1 Testing the Fiber Optic Link Segment Test the segment being attached to the FOT-F3 to verify that the cable meets the fiber budget specifications discussed in Chapter 2. Using a fiber optic power meter set, test your link segment as follows: 1.
Page 4 - 3 TESTING AND TROUBLESHOOTING 8. Take note of the reading on the optical power meter. This is your test level. 9. Subtract the reference level found in step 4 from the test level to find your dB loss for the fiber optic link segment, i.e., dB loss = Test Level - Reference Level.
Page 4 - 4 TESTING AND TROUBLESHOOTING 1. LAN-MD 5. FOT-F3 2. AUI Cable 6. AUI Cable 3. FOT-F3 7. LAN-MD 4. Fiber Optic Segment Figure 4-1. Installation Checkout.
Page 4 - 5 TESTING AND TROUBLESHOOTING 2. Using another AUI cable (6), connect the other LAN-MD (7) to another FOT-F3 (5) attached to the same fiber optic link segment as the FOT-F3. 3. Select and run test 6 - SERVER on the LAN-MD connected in step 1.
Page 4 - 6 TESTING AND TROUBLESHOOTING 4.2 USING LANVIEW The FOT-F3 Fiber Optic Transceiver uses Cabletron Systems’ LANVIEW, a built-in visual diagnostic and status monitoring system.
Page 4 - 7 TESTING AND TROUBLESHOOTING Figure 4-2. LANVIEW LEDs Receive (RCV) LED This yellow LED flashes to indicate that the transceiver is receiving a data packet from the network.
Page 4 - 8 TESTING AND TROUBLESHOOTING Transmit (XMT) LED This green LED flashes to indicate that a data packet is being transmitted onto the network by the device connected to the transceiver. The flash of the LED is pulse-stretched for viewing effect.
Ein wichtiger Punkt beim Kauf des Geräts Cabletron Systems FOT-F3 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cabletron Systems FOT-F3 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cabletron Systems FOT-F3 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cabletron Systems FOT-F3 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cabletron Systems FOT-F3 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cabletron Systems FOT-F3 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cabletron Systems FOT-F3 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cabletron Systems FOT-F3. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cabletron Systems FOT-F3 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.