Benutzeranleitung / Produktwartung FDDI des Produzenten Cabletron Systems
Zur Seite of 32
Title Page 7F06-02 FDDI Smar tSwitch ™ Interf ace Module User’ s Guide 903 9031672-02.
.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes ha ve been made.
Notice ii 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Notice 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide iii CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE . You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement.
Notice iv 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide DECLARATION OF CONFORMITY Application of Council Directiv e(s): 89/336/EEC 73/23/EEC Manufacturer’ s Name: Cabletron Systems, Inc. Manufacturer’ s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representativ e Name: Mr.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide v CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual ....................................................................... 1-1 1.2 The 7F06-02 Module ......................................
Contents vi 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide CHAPTER 5 T ECHNICAL SPECIFICATIONS 5.1 Standards ..................................................................................... 5-1 5.2 EMI .................................
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1-1 CHAPTER 1 INTR ODUCTION W elcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User Guide .
Chapter 1: Introduction 1-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1.2.1 Cable T ype and FPIMs The 7F06-02 module has two front panel connectors that interface to the 7X00 SmartSwitch Module through the chassis backplane. The front panel connections are standard Cabletron FPIMs.
Chapter 1: Introduction 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1-3 1.2.2 7C03 MMA C Smar tSwitch, the 7C04 W orkgr oup SmartSwitch and the 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is designed to be installed in the 7C03 MMA C SmartSwitch, the 7C04 W orkgroup SmartSwitch or the 7C04-R W orkgroup SmartSwitch.
Chapter 1: Introduction 1-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1.3.3 Connectivity The 7F06-02 Module has one backplane connection and two sets of A/B front panel FPIM connections. The backplane connection pro vides po wer to the 7F06-02 Module and a channel for communication with the 7X00 SmartSwitch Control Module.
Chapter 1: Introduction 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1-5 1.5 GETTING HELP If you need additional support related to this de vice, or if you hav e an y questions, comments,.
Chapter 1: Introduction 1-6 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 2-1 CHAPTER 2 NETW ORK REQUIREMENTS Before installing Cabletron Systems 7F06-02 Module, re view the network requirements outlined in this chapter . All requirements included in this chapter should be met to ensure satisfactory performance of the 7F06-02 Module.
Chapter 2: Network Requirements 2-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide The link distance is up to 2 kilometers on the multimode fiber optic cable as specified by ANSI MMF-PMD. 2.1.2 FPIM-02 and FPIM-04 The FPIM-02 has an RJ-45 connector supporting an Unshielded T wisted Pair (UTP) connection.
Chapter 2: Network Requirements 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 2-3 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector .
Chapter 2: Network Requirements 2-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-1 CHAPTER 3 INSTALLATION/REMO V AL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMA C .
Chapter 3: Installation/Remov al 3-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3.2 INSTALLING FPIMS The 7F06-02 module is shipped without FPIMs. T o install an FPIM, follo w the procedure belo w: 1. Remove the module if it is installed in the 7C03 MMAC SmartSwitch chassis by reversing the procedure in Section 3.
Chapter 3: Installation/Remov al 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-3 3.3 INSTALLING/REMOVING THE 7F06-02 MODULE The follo wing procedure details the installation and remov al procedure for the 7F06-02 module.
Chapter 3: Installation/Remo v al 3-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3.3.2 Removing fr om the 7C03 Smar tSwitch The 7F06-02 Module inserted in the 7C03 MMA C SmartSwitch can be remov ed upon proper remo v al of po wer . Follow the steps belo w and refer to Figure 3-3 to remov e the module.
Chapter 3: Installation/Remo v al 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-5 3.3.3 Installing in the 7C04 or 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is installed in the 7C04 or 7C04-R W orkgroup SmartSwitch using the follo wing steps and referring to Figures 3-4 and 3-5.
Chapter 3: Installation/Remo v al 3-6 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide Figure 3-4 Installing the 7F06-02 Module in the 7C04 W orkgroup SmartSwitch Figure 3-5 Installing the 7F.
Chapter 3: Installation/Remo v al 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-7 3.3.4 Removing the 7F06-02 fr om the 7C04 or 7C04-R W orkgr oup SmartSwitch The 7F06-02 Module, inserted in the 7C04 or the 7C04-R W orkgroup SmartSwitch, can be removed whene v er necessary .
Chapter 3: Installation/Remo v al 3-8 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide Figure 3-7 Removing the 7F06-02 Module fr om the 7C04-R W orkgroup SmartSwitch FANS SN 4 3 2 1 Ejector T.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 4-1 CHAPTER 4 T R OUBLESHOOTING 4.1 DIAGNOSTIC AND MONITORING SYSTEM The 7F06-02 Module uses LANVIEW , Cabletron Systems’ b uilt-in visual diagnostic and status monitoring system.
Chapter 4: T roubleshooting 4-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 4.2 P OR T RECEIVE LEDS T able 4-1 indicates the state of the receive port. 4.3 P OR T T RANSMIT LEDS T able 4-2 indicates the state of the transmit port. 4.4 A/B LINK LEDS T able 4-3 indicates the state of the A/B Link LEDs.
Chapter 4: T roubleshooting 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 4-3 Green Off Green Green THR U B, MA C on Secondary , Primary Bypasses Board Green Y ellow Green Green THR U B, M.
Chapter 4: T roubleshooting 4-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 5-1 CHAPTER 5 T EC HNICAL SPECIFICATIONS This chapter includes the technical specifications for 7F06-02 module. Cabletron Systems reserves the right to change these specifications at an y time without notice.
Chapter 5: T echnical Specifications 5-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 5.5 SAFETY It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allo wed limits of conducted and radiated emissions.
Ein wichtiger Punkt beim Kauf des Geräts Cabletron Systems FDDI (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cabletron Systems FDDI noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cabletron Systems FDDI - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cabletron Systems FDDI reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cabletron Systems FDDI erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cabletron Systems FDDI besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cabletron Systems FDDI verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cabletron Systems FDDI. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cabletron Systems FDDI gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.