Benutzeranleitung / Produktwartung 6-Amp Power des Produzenten ADTRAN
Zur Seite of 18
T ot al Access Rackmount 6-Amp Power Supply Battery Charger Inst allation and Maintenance Practice Document Numbe r: 61 180043L2-5D CLEI: V APUKT0C_ _ June 2005 ®.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice ii 61180043L2-5D Front Matter T r ademar ks Any brand names and product names includ ed in this manual are trademarks, registered trademarks, or trade names of their respectiv e holders.
61180043L2-5D iii R e vision Histor y Con v entions The following typographical conventi ons are used in this document: This font indicates a cross-reference link. First-ti me references to tables and figures are shown in this font . This font indicates screen menus, fields, and parameters.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice iv 61180043L2-5D T r aining ADTRAN offers training courses on ou r produc ts. These courses includ e overviews on product features and functions while covering applicat ions of ADTRAN’s prod uct lines.
61180043L2-5D v Contents General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . .
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice vi 61180043L2-5D Figures Figure 1. Total Access PS/BC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
61180043L2-5D 1 T otal Access Rac kmount 6-Amp P o wer Suppl y Ba tter y Char ger GENER AL This practice is an installation and maintenance guide for the ADTRAN ® Total Access ® Rackmount 6-Amp Po wer Supply Battery Charger (P S/BC). Figure 1 illustrates the PS/BC (P/N 1180043L2 ) right and left side panels.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 2 61180043L2-5D • Fuse protection • Positive ground • Battery Pack mou nting hardware included .
Description 61180043L2-5D 3 Batter y Disconnect Protection Cir cuit During battery operation a prote ction circuit di sconnects bat tery from the main output when battery voltage drops below 39 VDC, preventing over discharge. When AC returns, the main output provides regulated –54 VDC, batteries recharge, and the system returns to normal.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 4 61180043L2-5D LED Indication A set of three PS/BC multi color LEDs provide status for AC, D C, and battery charge condi- tions. See Table 1 for LED descriptions.
Installation 61180043L2-5D 5 INSTALLA TION After unpacking the Total Access PS/BC, inspect it for da mage. If damage has occurred, file a claim with the carrier, then contact ADTRAN Customer Service. Refer to “Appendix A, Warranty” for further informatio n.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 6 61180043L2-5D Mounting the PS/BC The PS/BC housing occupie s a nominal area 15.
Wiring Descriptions 61180043L2-5D 7 Alter nate Mounting Two alternate mounting methods include mounting directly to a wall using c ustomer supplied wood screws, or to a 16-gauge steel bracket (P/N 3265555) that mounts in the cabinet. Bracket mount location is normally at the battery position when batteries are mounted external to the cabinet.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 8 61180043L2-5D DC P o wer Output The 4-foot long, three co nductor PS/BC power outpu t wire originates at the –54V 6A OUTPUT modular connec tor and terminates at three #6 ri ng lugs for customer designated connection.
Operation 61180043L2-5D 9 Batter y Char ge/Discharge CA UTION To prevent battery discharge prior to system operation, do not con- nect the battery to the PS/BC un til the AC power is connected or imminent.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 10 61180043L2-5D SPECIFICA TIONS Power Factor specifications for the Total Access PS/BC are listed in Table 2 . PS/BC specifica- tions are listed in Table 3 .
61180043L2-5D A-1 A ppendix A W ar r anty W AR R ANTY AND CUSTOMER SER VICE ADTRAN will replace or repair this product wit hin the warranty peri od if it does not meet its published specifications or fails while in se rvice. Warr anty information can be fo und at www.
Carrier Networks Division 901 Explorer Blvd. Huntsville, AL 3580 6 ®.
Ein wichtiger Punkt beim Kauf des Geräts ADTRAN 6-Amp Power (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie ADTRAN 6-Amp Power noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für ADTRAN 6-Amp Power - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von ADTRAN 6-Amp Power reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über ADTRAN 6-Amp Power erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon ADTRAN 6-Amp Power besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von ADTRAN 6-Amp Power verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit ADTRAN 6-Amp Power. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei ADTRAN 6-Amp Power gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.