2 CONTENTS Introduction ................................................. 2 Warranty ...................................................... 2 User Notices ................................................ 3 Electrical Requirements .....................
3.
4 ELECTRICAL REQUIREMENTS CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up. The H5M dispenser requires 2-wire, grounded service rated 120, 208, or 240 volts ac, 20 amp, single phase. The H5MA, 230V-CE dispenser requires 2-wire, grounded service rated 230 volts ac, 40 amp, single phase, 50/ 60Hz .
5 INITIAL SET -UP CAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Remove the upper rear panel and rotate the control thermostat knob fully counterclockwise to the “ OFF ” position and r eplace the panel.
6 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T ech- nical Service Department.
7 TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Automatic refill will not operate after drawing hot water . Water flows into the tank con- tinuously (Dispenser discon- nected from power source). Water flows into the tank con- tinuously (Dispenser connected to power source).
8 TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Water boils continuously . Dispenser is making unusual noises. Ready indicator will not light. (when temperature is within 4 ° of its selected setting.) 1. T emperature control 2. Lime build-up 1.
9 SERVICE This section provides procedures for testing and replacing various major components used in this dis- penser should service become necessar y .
10.
11.
12 SERVICE (cont.) Solenoid Valve Location: The solenoid valve is located inside the rear of the dis- penser on the right side near the bottom. 6. Check the solenoid valve for coil action.
13.
14 FIG. 10 THERMOSTAT WIRING BLU/BLK to Limit Thermostat BLK to T erminal Block P1782 SERVICE (cont.) Thermostat Location: The mechanical thermostat is located inside the upper rear panel. T o test the thermostat, access will also be needed to the terminal block located inside the bottom access panel.
15 SERVICE (cont.) Liquid Level Board Location: The liquid level board is located inside the lower panel. Test Procedure: 1. Disconnect the dispenser from the power sour ce. 2. Remove the blue wire from terminal 1 and the pink wire from terminal 4 of the circuit board.
16 15. Move the probe's flat end to the dispenser hous- ing. The indication must be 0. 16. Move the probe's flat end away from the dispenser housing. The indication should again be: a.) 100 to 120 volts ac for 100 to 120 volt models, b.) 200 to 240 volts ac for 200 to 240 volt models, c.
17 Location: The contactor is located on the component bracket inside the lower rear panel. T est Pr ocedures: 1. Disconnect the dispenser from the power sour ce. 2. Disconnect the black wire from the contactor coil to the limit thermostat and black wire from the red wire on the main harness on two wire 240V mod- els.
18 BLK to left Tank Heater RED to Terminal Block(L2) BLK to Terminal Block (L1) RED to Right Tank Heater BLK to Limit Thermostat RED from Main Harness P1725 FIG.14 CONTACTOR WIRING contactor . Removal and Replacement: 1. Disconnect all the wires from the contactor .
19 4 3 12 LIQUID LEVEL BOARD BLU/BLK TANK HEATER 120 VOLTS A C 2 WIRE SINGLE PHASE 10243.0000D 1/99 © 1987 BUNN-O-MATIC CORPORATION SCHEMATIC WIRING DIAGRAM H5M L1 N BLK BLK BLK SOL WHI GREEN BLU WHI.
20 WIRING DIAGRAMS 4 3 12 LIQUID LEVEL BOARD BLK SW& THERMOSTAT 10262.0001A 11/99 © 1999 BUNN-O-MATIC CORPORATION SCHEMATIC WIRING DIAGRAM H5MA, 230V CE L1 L2 BLK SOL GREEN BLU BLK BLK (PROBE) P N K RED RED RED BLU/BLK BLK RED-12 BLK-12 N.O. N.O.
Ein wichtiger Punkt beim Kauf des Geräts Bunn H5M (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bunn H5M noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bunn H5M - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bunn H5M reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bunn H5M erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bunn H5M besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bunn H5M verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bunn H5M. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bunn H5M gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.