Benutzeranleitung / Produktwartung H10X des Produzenten Bunn
Zur Seite of 20
BU N N ® H10X OPERA TING & SER VICE MANU AL B UNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 10889.
2 W ARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and appearing within one year from the date of installation. In addition: 1.
3 USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels. 12593.0000 10044.0000 00656.0000 NOTICE ALL COMPONENTS ARE 200 TO 240 VOLT A.
4 ELECTRICAL REQUIREMENTS CAUTION - The dispenser must be disconnected from the power sour ce until specified in Initial Set-Up. This dispenser requires 2-wire, grounded service rated 208 or 240 volts ac, 40 amp, single phase. ( Refer to the dispenser ’ s dataplate for exact voltage requirement.
5 INITIAL SET -UP CAUTION - The dispenser must be disconnected from the power sour ce throughout the initial set-up, except when specified in the instructions. 1. Connect the dispenser to the power sour ce and turn on the water supply . 2. The “ HEA TER ” LED will glow for approximately five seconds.
6 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department.
7 TROUBLESHOOTING (cont.) PROBLEM Automatic refill will not operate af- ter drawing hot water . Water flows into the tank continu- ously . (Dispenser disconnected from power sour ce). Water flows into the tank continu- ously (Dispenser connected to power sour ce).
8 TROUBLESHOOTING (cont.) PROBLEM Water is cold (cont.) Water boils continuously . PROBABLE CAUSE 3. T ank heater 4. T emperature control 5. Dr y plug pr otection 1. T emperature control 2. Lime build-up REMEDY Refer to Service - T ank heater for testing procedures.
9 WARNING Very Hot Water Use With Care! ! WARNING Very Hot Water Use With Care! ! SERVICE This section provides procedures for testing and replacing various major components used in this dis- penser should service become necessar y . Refer to T roubleshooting for assistance in determining the cause of any problem.
10 SERVICE (cont.) Electronic Control Assembly T roubleshooting: Check these items first • Is circuit board popped out of bracket? • Is circuit board wet due to misaligned overflow tube? • Is wa.
11 SERVICE (cont.) Electronic Controls (cont.) Liquid Level Control T est Pr ocedure 1. Disconnect the dispenser from the power sour ce. 2. Check the voltage across terminals 3 & 4 of the electronic control assembly with a voltmeter . Con- nect the dispenser to the power source.
12 SERVICE (cont.) Electronic Controls (cont.) T emperatur e Control Flow Charts (cont.) Still Boiling ? Heater Light On While Boiling ? Retry Drain cup Retry Disconnect Blue Wire F rom Control Board .
13 SERVICE (cont.) Electronic Controls (cont.) 11. Disconnect the dispenser from the power sour ce. If voltage was present as described, return the new triac assembly to Bunn-O-Matic for credit. The tem- perature control of the system is operating properly .
14 T riac Assembly Removal and Replacement NOTE - Each triac installation requires the use of an approved silicone heat sink compound. Bunn-O-Matic recommends the use of Dow Corning 340 compound or equivalent. It can be pur chased direct from Bunn-O- Matic (P .
15 SERVICE (cont.) Limit Thermostat P1993 FIG. 5 LIMIT THERMOST A T T est Pr ocedure: 1. Disconnect the dispenser from the power sour ce. 2. There are two black wires on the limit thermostat terminals. One comes from the terminal block. The other goes directly to the tank heater terminal.
16 Location: The overflow protection switch is located within the side of the dispenser inside the copper overflow cup. For testing or removal of the overflow protection switch, access may also be needed by removing the two screws attaching the electronic control assembly to its mount- ing bracket.
17 Solenoid Valve Location: The solenoid valve is located within the side of the dis- penser on the right side near the bottom. T o test the solenoid valve, access will also be needed to the electronic control assembly . BUNN 90 psig max operating pressure Strainer/Flow Control # 22300.
18 WHI/BLU to Electronic Contol #1 RED to T erminal Block RED to Electronic Control #5 P1779 FIG. 10 SOLENOID V AL VE WIRING 5. Lift out the solenoid valve. 6. Remove the two 10-32 slotted-head screws hold- ing the solenoid valve to its mounting bracket.
19 SERVICE (cont.) T ank Heater Location: The tank heater is located in the tank lid. P1993 FIG. 11 T ANK HEA TER T est Pr ocedure: 1. Disconnect the dispenser from the power sour ce. 2. Check the voltage across the terminals of the tank heater with a voltmeter .
20 WIRING DIAGRAM 10889 091599.
Ein wichtiger Punkt beim Kauf des Geräts Bunn H10X (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bunn H10X noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bunn H10X - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bunn H10X reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bunn H10X erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bunn H10X besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bunn H10X verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bunn H10X. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bunn H10X gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.