Benutzeranleitung / Produktwartung AFPO-3 des Produzenten Bunn
Zur Seite of 25
AFPO-2 AFPO-2 SL AFPO-3 AFPO-3 SL F L AV O R IN P U T 1 2 W A T E R IN P U T RE FI LL M A I N PO W E R 2 1 1 2 3 3 3 FLA V O R OU T P U T F LA V O R O U T PU T WA T E R OU T PU T FL A V O R O U T P U .
2 41093 030912 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal ser vers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor .
3 USER NOTICES All notices on the equipment are written for your protection. All notices are to be kept in good condition. Replace any unreadable or damaged labels. CONTENTS User Notices ................................................................
4 CLEANING RECOMMENDED WEEKL Y CLEANING: This should be done in conjunction with the recommended weekly cleaning of your machine. The Hoppers must be empty before starting. 1. Prepare a 1 gallon cleaning solution consisting of 1 gallon of hot water and a sanitizing cleaner which contains 3-5% chlorine based sanitizer .
5 F LA VO R INPUT 1 2 W AT ER INPU T REFILL MAIN POWE R 2 1 1 2 3 3 3 FLA VO R OUT P UT FLA VO R OUT P UT W AT ER OUTP UT FLAVO R OUTP UT WA T ER OUTP U T WAT ER OUT P UT Mix ratio (water/flavor) Time for FLA VOR OUTPUT (1/2 cup) Time for W A TER OUTPUT (1 cup) 1+1 assume 20 sec.
6 FLA VOR INPUT 1 2 WAT E R INPUT REFILL MAIN POWER 2 1 1 2 3 3 3 FLA VOR OUTPUT FLA VOR OUTPUT WAT E R OUTPUT FLA VOR OUTPUT WAT E R OUTPUT WAT E R OUTPUT OPERA TING CONTROLS A. MAIN POWER ON/OFF The main power ON/OFF switch is located on the right of the front panel just above the power cord.
7 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Service Department.
8 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE 6. Main ON/OFF switch 7. Probe box LOW/OFF/HIGH switch - es 8. Circuit board 9. Vacuum switch 10. Vacuum/Supply pump 11. Pump (flavor) start switches 1. No water 2. Needle valve 3. Solenoids 1. Motor overheat REMEDY Refer to Service - Main ON/OFF Switch for testing procedure.
9 FL A V O R INPU T 1 2 WAT ER IN P U T R EF IL L M AI N PO W E R 2 1 1 2 3 3 3 F LA VOR O U T P UT FL A V O R O UT P U T W AT E R O UT P U T FL A VO R OU T P U T WA TER OU T P U T W AT ER O UT P U T SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessar y .
10 J4 J1 J2 J3 OF F O N OF F O N OF F O N OF F O N SERVICE CIRCUIT BOARD FIG. 2 CIRCUIT BOARD P1520 Location: The circuit board is located inside the autofill box, mounted on the right side of the solenoid mounting bracket under the switch panel. T est Procedure: 1.
11 FLAVOR INPU T 1 2 WATER INP UT REFILL MAI N POW ER 2 1 1 2 3 3 3 FLAV OR OUTPUT FLAV OR OUT PUT W ATER OUTPUT F L A VOR OUT PUT W A T ER OUT PUT WATER OUT PUT SERVICE Location: The fuse holder is located on the lower right front of the autofill box just to the left of the power cord.
12 FLAVOR INPU T 1 2 WATER INP UT REFILL MAI N POW ER 2 1 1 2 3 3 3 FLAV OR OUTPUT FLAV OR OUT PUT W ATER OUTPUT F L A VOR OUT PUT W A T ER OUT PUT WATER OUT PUT P1522 FIG. 7 MAIN ON/OFF SWITCH TERMINALS BLKfromFuseHolder BLKtoSolenoid(Water) Switch #2 AFPO-2 & 3 MAIN ON/OFF SWITCH FIG.
13 BU N N ® Mov ing P a rts . D o no t op e ra t e unit w ith this pa ne l rem oved. Ris k Of Ele ct r ica l Sho ck . D iscon nec t po w er befor e ser vi ci ng u nit. CH ARG E Type R22, Am ou nt _ _ OZ. Design Pr ess ur es: High _ _ L o w _ _ Suctio n Pr es su re _ _ Probe Boxes: 1.
14 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O UTP U T W A T ER O UTP U T W A T ER O UTP U T SERVICE (cont.
15 FLAVOR INPUT 1 2 WATER INP UT RE FI LL MAI N POW ER 2 1 1 2 3 3 3 FLAV OR OUT PUT FLAV OR OUT PUT WATER OUT PUT FLAV OR OUT PUT WATER OUT PUT WATER OUT PUT SERVICE (cont.) REFILL SWITCHES FIG. 14 REFILL SWITCHES Location: The refill switches are located on the upper right front of the autofill box.
16 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O U TPU T W A T ER O UTP UT W A T ER O UTP U T SERVICE (cont.) SOLENOIDS FIG. 16 SOLENOIDS Location: The solenoids are located inside the autofill box.
17 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O UTP U T W A T ER O UTP U T W A T ER O UTP U T SERVICE (cont.
18 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O UTP U T W A T ER O UTP U T W A T ER O UTP U T SERVICE (cont.
19 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O UTP U T W A T ER O UTP U T W A T ER O UTP U T SERVICE (cont.
20 SERVICE (cont.) V ACUUM/SUPPL Y PUMP TUBE INST ALLA TION FIG. 24 TUBING ST ART POSITION P1542 ROLLERS PUMP HEAD TUBING KEY ENTRY PORT EXIT PORT FIG. 25 TUBING LOADED ROTOR ROTOR SHAFT P1541 2. Separate the two halves of the pump and carefully remove the tubing from within.
21 V ACUUM SWITCHES FIG. 26 V ACUUM SWITCHES Location: The vacuum switches are located inside autofill box, mounted on the left side of the solenoid mounting bracket just below the needle valves. T est Procedure: 1 . Disconnect the dispenser from the power source.
22 PIPING DIAGRAM (AFPO-2) The only difference between the AFPO-2/3 and AFPO-2/3 SL is the SL models have a water output line and a flavor output line for each product. This allows the water and flavor to be mixed in the hoppers. Refer to the illustration below when connecting the lines.
23 GRN SOL #1 SOL #2 PUMP #1 PUMP #2 10 AMP MAIN ON/OFF SWITCH REFILL ON/OFF SWITCH #1 REFILL ON/OFF SWITCH #2 J4-1 2 3 4 5 6 7 8 9 J4-10 C I R C U I T B O A R D L1 N BLK BLK BLK B L K B L K B L K SOL.
24 41093 040408.
25 GRN SOL #1 SOL #2 PUMP #1 PUMP #2 10 AMP MAIN ON/OFF SWITCH REFILL ON/OFF SWITCH #1 REFILL ON/OFF SWITCH #2 J4-1 2 3 4 5 6 7 8 9 J4-10 C I R C U I T B O A R D L1 L2 BLK BLK BLK B L K B L K B L K SO.
Ein wichtiger Punkt beim Kauf des Geräts Bunn AFPO-3 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bunn AFPO-3 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bunn AFPO-3 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bunn AFPO-3 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bunn AFPO-3 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bunn AFPO-3 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bunn AFPO-3 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bunn AFPO-3. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bunn AFPO-3 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.