® Section 61180403L1-5B Issue 2, December 2004 CLEI Code: VAIMZ70J_ _ 61180403L1-5B 1 Trademarks: Any brand names and product name s included in this docum ent are trademarks, regi stered tradem arks, or trade nam es of their respecti ve holders. CONTENT S 1.
2 Issue 2, December 2004 61180403L1-5B •P L A R D 3 •T a n d e m •D P O • FX Ringdown • TO w/Sealing Code Features The basic features of the FXS/DPO include the following: • µ -law encoding and decoding • Supports ground start, lo op start, PLAR, DPO, and Tandem, TR08SP, TR08UVG, TR08AUTO, and FX Ringdown • Supports 900 ohm s (+2.
61180403L1-5B Issue 2, December 2004 3 Instructions for Inst alling the Module To install the FXS/DPO, perform the following steps: 1. If pres ent, remove the Access Module Blank (P/N 1 175099L1) from the appropriate access module slot of the T otal Acce ss chassis.
4 Issue 2, December 2004 61180403L1-5B Hardware Provisioning DIP switches SW1 , SW2 , SW3 , and SW4 are used to provision many of the FXS/DPO options. Ta b l e 4 on page 5 summ arizes the options pro visioned by the DIP switches. Figure 2 o n page 6 provides a grap hic detail of the four switches and the printed circuit board markings.
61180403L1-5B Issue 2, December 2004 5 T able 4. DIP Switches Sw .-Segment Label Function/Desc ription 1-1 D3/D4 D3 or D4 Signaling (PLAR only) 1-2 1-3 MODE 1/OFF MODE 2/OFF SW1-2 SW1-3 Mode Selected .
6 Issue 2, December 2004 61180403L1-5B Figure 2. DIP Switches Detail Sof tware Provisioning The FXS/DPO is provisioned by connecting a VT100 terminal or a computer ru nning a terminal emulation program to the craft interface ADMIN port located on the System Controller Unit (SCU ) front panel.
61180403L1-5B Issue 2, December 2004 7 . T able 5. FXS/DPO General Opti ons Function Optio n Description Mode Loop S tart Ground Start TR08 Single Part y (3) TR08 Universal VG (3) TR08 Auto (3) PLAR D4 PLAR D3 Ta n d e m (3) DPO FX Ringdown (3) TO w /S C (3) This option selects the signaling mode of the FXS/DPO.
8 Issue 2, December 2004 61180403L1-5B T able 6. FXS/DPO Mode Options Mode Description Loop Start This option selects ANSI T1.403 FXS Loop S tart mode of operation. Ground Start This option selects ANSI T1.403 FXS Ground Start mode of operation. TR08 Single Party This option selects GR-08-Core Loop S tart mode of operation.
61180403L1-5B Issue 2, December 2004 9 T able 7. FXS/DPO T andem Options Function Option Description Conversion Mode T andem Inactive Loop Start Ground Start This option sets the conversion from E&M (2-state) signali ng on the PCM interface to loop star t or ground start signaling on the loop.
Figure 3. FXS/DPO Menu Tree 1. Configuration 2. Provisioning 3. Status 4. Test 1. Digital Network Loopback 2. 1004 Hz Tone Test 2. 2-Wire Termination 1. 600 + 2.16 2. 900 + 2.16 Enter Value (-7.0...+9.0) 3. Transmit TLP 1. Loop Start 3. TR08 Single Party 2.
61180403L1-5B Issue 2, December 2004 11 4. T EST FEATURES The FXS/DPO supports the following tests for each port: • Digital Network Loopback • 1004 Hz Tone Generation • Network Hook Test • Customer Ringing Test These test are used to support circuit turn-up and maintenance efforts.
12 Issue 2, December 2004 61180403L1-5B T able 8. Specifications Performance Loop Current: T ransmit TLP: Receive TLP: T erminating Impedance: Return Loss: T ransHybrid Loss: Longitudinal Balance: Frequency Response: Idle Channel Noise: PCM Encoding/Decoding: DC Supervisory Range: 23 mAmp nom inal 20 mAmp minimum –7.
Ein wichtiger Punkt beim Kauf des Geräts ADTRAN 1109403L2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie ADTRAN 1109403L2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für ADTRAN 1109403L2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von ADTRAN 1109403L2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über ADTRAN 1109403L2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon ADTRAN 1109403L2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von ADTRAN 1109403L2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit ADTRAN 1109403L2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei ADTRAN 1109403L2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.