Benutzeranleitung / Produktwartung CONDENSING GAS FURNACE 340MAV des Produzenten Bryant
Zur Seite of 12
USER’S INFORMA TION MANU AL MODEL 340MA V , 350MA V , 352MA V , 355MA V CONDENSING GAS FURN A CE — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T T O DO IF YOU SMELL GAS: — Do not try to light any appliance.
INST ALLA TION D A T A Date Installed Dealer Name Address City State Zip T elephone FURNA CE Product No . Model No . Serial No . SPLIT -SYSTEM OUTDOOR UNIT: Product No .
3 FURN A CE COMPONENTS Combustion-air intake connection to ensure contaminant-free air (right or left side). Burner sight glass for viewing burner flame. Burner assembly (inside). Operates with energy- saving inshot burners and hot surface ignitor for safe, dependable heating.
4 IMPOR T ANT F A CTS Y our gas furnace uses air from outside the home for combustion and venting. It is not to be installed using in-house air . Therefore, both pipes must terminate outside the structure and must not be obstructed in any w ay .
5 a 8 9 10 2. Close the external manual g as v alve. (See Fig. 9.) 3. T urn of f electrical supply to the furnace. (See Fig. 10.) 4. Remov e the main furnace door . (See Fig. 11.) 5. Gas valve will ha ve EITHER a con- trol switch or control knob to turn OFF or ON.
6 16 17 18 SHUTTING DO WN Y OUR FURN A CE Should you need to shut do wn your furnace for service or maintenance, you will need to turn the furnace of f. 19 O P E N ® 20 The follo wing procedures must be follo wed: 1. Set your room thermostat to the lo west temperature setting.
7 BLO WER COMP AR TMENT a. Remo ve main furnace door . (See Fig. 23) b . Remove blo wer access panel. (See Fig. 24) NO TE: It will be necessary to remov e 2 screws • AIR FIL TER LOCA TED IN FIL- TER CABINET a. Remo ve fi lter cabinet door (See Fig.
8 29 30 COMBUSTION AREA AND VENT SYSTEM V isually inspect the combustion area and vent system before each heating season. Make sure that all PVC pipes leading into the comb ustion area and vent are free from an y cracks and sags. Also check the comb ustion-air intake and vent pipes on the outside of your home for blockage.
9 34 35 7. Pour 1 quart of antifreeze into funnel/tube. Antifreeze should run through inducer housing, over fi ll condensate trap, and fl ow into open fi eld drain. (See Fig. 35.) 8. Remov e funnel and tube from inducer housing and replace drain connection cap and clamp.
10 39 40 41 BEFORE Y OU REQUEST A SER VICE CALL If your furnace is not operating or not performing properly , you may sav e the expense of a service call by check- ing a fe w things yourself before calling for service. FOR INSUFFICIENT AIRFLOW : • Check for dirty air fi lter(s).
11 MODEL 340MA V AND 350MA V DIA GNOSTIC CHAR T (See Fig. 3.) NO TES: 1. Light on continuously means control has po wer and working properly . 2. The fault code is a 2-digit n umber . The fi rst digit is determined by the number of short fl ashes of the light and the second digit is determined by number of long fl ashes of the light.
Cancels: OM05-30 OM05-32 © 2001 Bryant Heating & Cooling Systems, 7310 W . Morris St., Indpls., IN 46231 12 Printed in U.S .A. Catalog No . 5335-202 3-01 MODEL 355MA V DIA GNOSTIC CHAR T (See Fig. 4.) NO TES: 1. Red light 1 on continuously means furnace is operating in emergency heat.
Ein wichtiger Punkt beim Kauf des Geräts Bryant CONDENSING GAS FURNACE 340MAV (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bryant CONDENSING GAS FURNACE 340MAV noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bryant CONDENSING GAS FURNACE 340MAV - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bryant CONDENSING GAS FURNACE 340MAV reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bryant CONDENSING GAS FURNACE 340MAV erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bryant CONDENSING GAS FURNACE 340MAV besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bryant CONDENSING GAS FURNACE 340MAV verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bryant CONDENSING GAS FURNACE 340MAV. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bryant CONDENSING GAS FURNACE 340MAV gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.