340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140 Product Data The model 340AAV Multipoise Condensing Furnace is specifi- cally designed to meet the needs of the new construction market. This high-efficiency furnace utilizes a unique 4-way multipoise design and compact size to fit where other fur- naces will not.
—2— 340AAV A05070 NO TE S : 1. Minim u m ret u rn - a ir opening s a t f u rn a ce, bas ed on met a l d u ct. If flex d u ct i s us ed, s ee flex d u ct m a n u f a ct u rerí s recommend a tion s f or e qu iv a lent di a meter s . 2. Minim u m ret u rn - a ir opening a t f u rn a ce: a .
—3— 340AAV Thi s for ced ai r fur nac e i s equi pped for use w i th natur al gas at alt i t udes 0 - 10, 000 f t (0 - 3, 050m), except 140 si ze F ur naces a re only approved for alt it udes 0 - 7,000 ft .
—4— 340AAV Controls—Thermostats and Zoning Non-Programmable Thermostat Selection * Model HP and 2S thermostat must be field converted to air conditioner operation. **Thermidistat Control is versatile and can be configured for multiple use and staging, it must be configured for each specific application.
—5— 340AAV SPECIFICATIONS See notes on page 7. UNIT SIZE 024040 036040 024060 036060 048060 036080 RATINGS AND PERFORMANCE Input Btuh* 40,000 40,000 60,000 60,000 60,000 80,000 Output Capacity BTU.
—6— 340AAV SPECIFICATIONS See notes on page 7. UNIT SIZE 048080 060080 048100 060100 060120 060140 RATINGS AND PERFORMANCE Input Btuh* 80,000 80,000 100,000 100,000 120,000 140,000 Output Capacity.
—7— 340AAV * Gas input ratings are certified for elev ations to 2000 ft. F or elevations abo ve 2000 ft, reduce ratings 2% f or each 1000 ft above sea le vel. In Canada, derate the unit 5% from 2000 to 4500 ft abov e sea lev el. † Capacity and AFUE in accordance with U .
—8— 340AAV COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) Applications MAXIMUM ALLOWABLE PIPE LENGTH (FT) ALTITUDE (FT) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.
—9— 340AAV COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) Applications MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.
—1 0— 340AAV COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) Applications MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.
—1 1— 340AAV MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* * Pipe length (ft) specified for maximum vent pipe lengths located in unconditioned spaces.
—1 2— 340AAV ACCESSORIES SIDE FILTER RACK* DIMENSIONS (In.) * Dimension A will change accordingly as dimension D is lengthened or shortened. † Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in.
—1 3— 340AAV AIR DELIVERY—CFM (With Filter)* * A filter is required f or each return-air supply . • For horiz ontal and downflow applications , use “1 side or bottom ” or “bottom only ” as airflow ref erence. UNIT SIZE RETURN-AIR SUPPLY SPEED EXTERNAL STATIC PRESSURE (In.
—1 4— 340AAV COMBU S TION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) A/C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GA S -FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE COMBU S TION.
—1 5— 340AAV COMBU S TION–AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDEN S ATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE A05066 DIRECT VENT/2-PIPE APPLI.
—1 6— ©Bryant Heating & Cooling systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. edition date: 01/06 Catalog No. PDS 340A.40.2 Manufacturer reserves the right to change, at any time, specifications or designs without notice and obligations Replaces: PDS 340A.
Ein wichtiger Punkt beim Kauf des Geräts Bryant 340AAV (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bryant 340AAV noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bryant 340AAV - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bryant 340AAV reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bryant 340AAV erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bryant 340AAV besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bryant 340AAV verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bryant 340AAV. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bryant 340AAV gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.