Pr oduct Dat a Model 213A Lega cy t -- RNC S erie s Heat Pump wit h Puron r Refrigerant Si zes 018 to 060 1 - - 1 / 2 To 5 N o m i n a l To n s Fig. 1 – 213A Brya nt’ s heat pum ps wit h Puron r r efr iger ant provi de a col lec tion of features un match ed b y an y oth er family o f eq uip men t.
2 MODEL NUMBER NOMENCLA T URE 1 2 34 5 6 7 8 9 1 0 1 11 2 1 4 N N N A A/N N N N N A/N A/N N A 21 3 A N A 0 3 6 0 0 0 0 Pro duct Fa mi ly Tie r SEER Major Series Volt age V ariations Cooling Capaci ty .
3 PHYS ICAL DA T A UNIT SIZE SER IES 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A Operat ing Weig ht (lb ) 146 162 203 207 246 263 279 Shippin g Weight (lb) 169 189 235 239 278 293 311 Compressor T ype Scroll REFRIGERAN T Puron ® (R - - - 410A) Cont rol TXV (Puro n Hard Shutoff) Charge ( lb) 5.
4 ACCESSO RIES ORDER NUM BER DES CRIPT ION 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A HC34GE239 BALL BEARING M O TOR X HC34GE240 BALL BEARING M O TOR X X HC38G.
5 ACCESSO R Y USAGE GUIDELINE ACCESSORY RE QUIRED F OR LOW - - - AMBIE NT COOLING A PPLICATIONS (Below 55 ° F) REQUI RED FOR LONG LINE APPLICATIONS* (Over 80 F t.
6 Accesso ry Descrip tion an d Usag e (Listed A lph ab etical ly) - - CO NTI NUED 10. Outdoor A ir T empe rat ure Se nsor De si gne d for use wi th Brya nt Ther mosta ts l ist ed in t his publi cat ion. This de vice e nable s the ther mosta t to displ ay the outdoor te mper at ure.
7 ELECTRICAL DA T A UNI T SIZ E V/P H OPER VOL TS* CO MPR FAN MCA MIN WIRE SIZE { MIN WIRE SIZE { MAX LENGTH (ft.) } MAX LENGTH (ft.) } MAX FUSE** or CK T BRK AMPS MAX MIN LRA RLA FLA 60 ° C 75 ° C 60 ° C 75 ° C 018 - - - A 208 - - - 230/1 253 197 48 9.
8 DIMENSIONS 213A.
9 213ANA BALANCE POINT WORKSHEET 0 10 20 30 40 50 60 70 80 - - 1 0 0 1 02 03 04 05 06 07 08 0 OUTDOOR TEMPERA TURE , ºF BUILDI NG HEA T LOSS, UNIT I NTEGRA TED HEA TI NG CAP ACI TY , MBTUH 0.
10 COMBINA TION RA TINGS Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 018 - - - A *FY4ANF018 17,100 TDR&TXV 13.
11 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 024 - - - A CNPH*2417A** 22,800 TDR&TXV 14.
12 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 030 - - - A FX4CNF030 29,600 TDR&TXV 14.
13 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 030 - - - A CSPH*3012A* * 29,200 TDR&TXV 14.
14 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 036 - - - A CNPH*3617A** 33,400 TXV 13.
15 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 042 - - - A CAP**4221A** 40,000 TDR&TXV 14.
16 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 042 - - - A CNPV*4824A** 40,500 TDR&TXV 13.
17 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 048 - - - A CNPH*4821A** 45,000 TXV 13.
18 DET AILED COOLING CAP ACITIES EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capa.
19 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
20 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
21 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
22 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
23 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
24 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
25 HEA T PUMP HEA TING PERFORMANCE INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW.
26 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
27 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
28 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
29 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
30 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
31 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
32 GUIDE SPECIFICA TIONS GENERAL System Description Outdoor- - mounted, air- -cooled, split - -system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor , an air - - cooled coil, propeller - -type condenser fan, and a control box.
Ein wichtiger Punkt beim Kauf des Geräts Bryant 213A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bryant 213A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bryant 213A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bryant 213A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bryant 213A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bryant 213A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bryant 213A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bryant 213A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bryant 213A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.