Benutzeranleitung / Produktwartung TGHE-199E-N(X) des Produzenten Bradford-White Corp
Zur Seite of 64
238-48794-00C 07/11 Bradford White EverHot Condensing Tankless Gas Water Heater For Exterior Installation TGHE-160E-N(X) and TGHE-199E-N(X) INSTALLATION AND OPERATION INSTRUCTION MANUAL With Troub.
2 SECTION I: IMPORTANT INFORMATION TABLE OF CONTENTS I IMPORTANT INFORMATION ......... 2 V II OPERATING INSTRUCTIONS ....... 39 II SPECIFICATIONS .......................... 6 TEMPERATURE ADJUSTMENT ................................ 41 III INSTALLATION INSTRUCTIONS .
3 DO NOT store or use gasoline or other flamm able, combustibl e, or corrosive vapors and/or liquids in the vicinity of this or any other appliance. This water heater is for outdoor installati on only. Do not install indoors. This water heater is eq uipped with an adjustable t hermostat to control water tempe rature.
4 DO NOT tamper with or alter the water h eater and/or controls. DO NOT operate water heater with jum pered or absent controls or safety devices. DO NOT operate water heater if any external part ha s been under water.
5 Liquefied petroleum ga ses/propane ga s is heavier than air and will remain at floor level if there is a leak. Basements, crawl spaces, cl osets and areas below gr ound level will serve as pockets for accumulation of leakin g gas. Before lighting, smell all around the appliance area for gas.
6 SECTION II: SPECIFICATIONS Table 1. Specifications . Model TGHE-160E-N(X) TGH E-199E-N(X) Minimum Rate Btu/h 9,500 (Natural) / 10,300 (Propane) Maximum Rate Btu/h 157,000 199,000 Flow Rate (Min-Max) * 0.4-8.0 GPM (1.5-30 L/min) 0.4-9.8 GPM (1.5-37 L/min) Flow Rate (45°F rise) 6.
7 Dimensions TGHE-160E-N(X), TGHE-199E-N(X) Table 2. Water Heater Dimensions. DIM DESCRIPTION TGHE-160E-N(X) In. (mm) TGHE-199E-N(X) in. (mm) A Width 18 ½ (470) 18 ½ (470) B Depth 10 5/8 (271.9) 10 5/8 (271.9) C Height - Unit 26 3/8 (670) 26 3/8 (670) D Height - with brackets 28 3/8 (721.
8 Figure 1. Graph Showing Pressure Drop v. Water Flow Rate. Figure 2. Graph Showing Water Flow Rate v. Temperature Rise. TGHE-160E-N(X) TGHE-199E-N(X) Pressure Drop (psi) Pressure Loss (ft head) TGHE-.
9 SECTION III: INSTALLATION INSTRUCTIONS CAUTION If building cold water suppl y has a back-flow prevente r, check valve or wat er meter with check va lve, provisions for thermal expansion of water in the hot water system must be p rovided.
10 WARNING UNPACKING INSPECT SHIPMENT carefully for any signs of damag e. 1. All equipment is carefully manufactured, insp ected and packed. 2. Any claims for damage or shorta ge in shipment must be file d immediately with Bradford White Corporation and noted on the Bill of Lading.
11 MOUNT WATER HEATE R ON T HE W ALL This water heater must be in stalled outdoors. Refe r to Table 3 clearan ces under overhangs, windows, doors, etc. Also, avoid locations where there is hea vy water run-off fro m roofs. Determine the proper height and location for the water heater to b e installed.
12 State Regulations NOTICE BEFORE INSTAL LATIO N Bradford White direct-vent applia nce mu st be installed by a state qualifi ed or licen sed contractor. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachuse tts (248CMR 4.
13 FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B I M C F B B E D L G A H K VENT TERMINAL AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED Figure 3.
14 Table 4. Installation Clearan ces. Ref Description Canadian Installations US Installations A Clearance above grade, veran da, porch, deck, or balcony 12 inches (30 cm) 12 inches (30 cm) B Clearance.
15 Local codes supersede the se clearances. Avoid termination locations near a dryer vent. Avoid termination locations near commercial cooking exhaust s. 2" 36" 12" INSIDE CORNER * (0.30 m) to an inside (50 mm) between termi nals at same level (0.
16 High Altitude Installations The default setting for the water is 0-2,000 ft (0-61 0 m) with dip switch numbers 2 and 3 in the OFF position. If this water heater is i nstalled at a highe r altitude, it is necessary to modify the dip swit ch settings according to Table 5.
17 SECTION IV: WATER CONNECTIONS WARNING Failure to install and maintain a new, listed pressu re relief valve will release the manufacturer from any claim, which might result from excessive temperature and pressures. Keep clear of the pressure relief valve di scharge line outlet.
18 potable water. Unions should be installed on both the hot and cold water lines for future servicing and disconnection of the water heater. Install a shut -off valve in the cold water sup ply line.
19 Figure 5. Scald Warning . Table 7. Approximate scald time/temperatures. APPROXIMATE TIME/TEMP ER ATURE RELATIONSHIPS IN SCALDS 120°F (49 C) More than 5 minutes 125°F (52 C) 1½ to 2 minut.
20 Figure 6. Recommended Piping for a Basic Installation..
21 Figure 7. Recommended Piping for a Circulation Systems . Pump to be of bronze or stainless construction.
22 Recommended Piping for Po wer Failure Freeze Protection As long as electrical power a nd gas are supplied to the EverHot water h eater, freeze protection is provided to the heat exchanger and pipi ng inside the wate r heater with ambient temperatures as cold as -4 F (-20 C), when protected from dire ct wind exposure.
23 PRESSURE RELIEF VALVE Keep clear of the pressure reli ef valve di scharge line outlet. The discharge may be hot enough to cause scald injury. The water is unde r pressure and may splash.
24 Combination Water and Space Heating Applications – Commercial Use Water Heaters Only Commercial use water h eaters may be used for space heating or combination space heating/potable water heating applications, provided the followin g requirements and recommended piping di agrams are carefully followed.
25 Note: in Massachusetts, the following must be done: Tempered potable water must meet temperatures in 248 CMR. All water piping must be insulat ed in accordance with 780 CMR (Massachusetts energy code ).
26 SECTION V: GAS CONNECTIONS WARNING Connect this water heater only to the ty pe of gas as shown on the rating plate. Use clea n black iron pipe or equivalent material approved by local codes and ordinances. Dirt and scale from th e pipe can enter the gas valve a nd cause it to malfunctio n.
27 Check the type of ga s and the gas inl et pressure before connecting the EverHot ® water heater to the gas supply. If the gas su pply type does not match the type shown on the water heater rating pl ate, then DO NOT connect the water he ater. Contact your Bradford White supplier for the correct water heater.
28 INITIAL OPERATION AN D TESTING (INSTALLER ONLY) 1. Open the gas and water supply valves to the water heater. 2. Check for water and gas le aks. Use soap solution to check for gas leaks.
29 SECTION VI: ELECTRICAL CONNECTIONS WARNING Turn off or disconnect the electrical power supply to the water heater before servicing. Label all wires prior to disconn ection when servicing controls. Wiring erro rs can cause improper and dangerous operation.
30 WARNING DO NOT adjust any dipswitch settings on PC board u nless instructed to do so. Figure 10. Ladder Diagram. WATER LEVEL DETECTING CIRCUIT WATER LEVEL ELECTRODE TWIN THERMISTOR.
31 Figure 11. Wiring Diagram for TGHE Models..
32 TEMPERATURE CONTROLS The included temperature control a llows the end user to set the hot water supply temperature and will display certain diagnostic cod es of the water heater if there is a malfunction.
33 WARNING Do not adjust this water h eater in any residential application above 120ºF. If this water heater is used in a commercial application where temperatures in excess of 120ºF are required, use an ASSE approved mixing device. WARNING This water heater is equipped with an energy cut out device to prevent overheating.
34 Figure 12. Remote Control and the Description of Function s on All Controls. Residential Control, p/n 239-4878 8-00 Commercial Control, p/n 239-487 89-00 Installation of Control(s) 1. The controls may be wired in parallel o nly. 2. Mark the hol es on the wall using the co ntrol mounting plate and drill two mounting h oles using a 3/32” (2.
35 8. Remove the plastic cover from the PCB and ele ctrical connections. 9. Thread th e cable through the access hole at th e ba se of the water h eater and connect the wires to the control terminals on the right hand side of the PCB. 10. Secure the control cable using the cl amp provide d in the control compartment.
36 Troubleshooting – Electrical There are a number of (live) tests that are required when fault finding this product. Extre me care should be used at all times to avoid contact with energiz ed components inside the water heater. Only trained and qualified service tech nicians should attempt to repair this pr oduct.
37 Table 16. (FM) Combusti on Fan Motor. Wire Color Voltage Resistance Connector No. Pin Nos. Red-Black 6-45 VDC n/a L1 1-2 White-Black 5-10 VDC 9.2-9.4k ohms L1 2-4 Yellow-Black 11-13 VDC 3.5-3.9k ohms L1 2-3 Set your meter to the hertz scale. Reading across the white and black wires at terminals 2 and 4 you should read between 60 and 420 hertz.
38 Table 21. Remote Controls. Wire Color Voltage Resistance Connector No. Pin Nos. Terminals A1 10-13 VDC 1.5-3.0k ohms A 1-3 Frost Protection: This unit has frost protection he aters mounted at diffe rent points to protect the water the water heater from freezing.
39 SECTION VII: OPERATING INSTRUCTIONS WARNING Water heaters are he at-producing app liances. To avoid damage or injury there must be no materials stored against th e water heater or direct vent sy stem, and proper care must be taken to avoid unnecessary contact (especially by children ) with the water heater a nd direct vent system.
40 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFO RE OPERATING WARNING: If you do not follo w these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This water heater does not have a pilot.
41 CAUTION In climates wh ere below free zing temper atures may occ ur, the water heater must b e drained when power is off to the water heater to prev ent free ze damage to the heat exchanger. Drain sol enoids are recommended to prevent freeze damage during p ower failures in cold climate regions.
42 2. To set the de sired temperature on the control, all hot water faucets must be closed. If there are more remote control s installed, press t he “Priority” button on the control you want to change the setting on and the “Priority” indicator light will glow.
43 SCALDING Figure 17. Scalding Warning. This water heater can deliver scalding temperature water at any faucet in the system. Be careful whenever using hot w ater to avoid scalding injury. Cer tain applianc es, such as dishwas hers and automatic clothes washers may require increased wate r temperature.
44 DIAGNOSTIC CODES ON THE TEMP ERATURE CONTROL DISPLAY The Bradford White EverHot tankless water heate rs have the ability to monitor and display any operating faults on the control display. The diagnostic codes will display on the monitor and will assist in servicing the water heater.
45 Code Code Description Remedy 16 Over Temperature Warning Check for restrictions in air flow around unit and vent terminal. Check for low water flow in a circulating system causing sh ort-cycling. Check for foreign materials in combustion ch amber and/or exhaust piping.
46 SECTION VIII: MAINTENANCE WARNING Always turn off the electrical power supply, the manual ga s valve, and the manual water control valve whenever servicing this applian c e. KEEP THE WATER HEATER AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS.
47 CAUTION Before manually operating the valve, make su re t hat a drain line has been attached to the valve to direct the discharge to a n open drain. Failure to take this precaution could mean contact with extremely hot water passing out the valve during this checking operation.
48 Figure 19. Piping for Mineral Scale Flushing. Rinnai Wa ter Heater Ga s Su ppl y V1 V3 V2 V4 H1 H2 H3 Ci rc u la t i ng Pu m p 5 g all on pail o f vi r gin, fo od g r ad e , w h i t e v ine g a r (o r vir gin, fo od gr a d e , cit ri c a c i d) .
49 Common Troubleshooting Commen ts on the Operation of the EverHot ® Tankless Water Heater Comment: I don’t have any hot water when I open the tap! Make sure the gas and electricity is turned on to t he water heater. The temperature display should have the green light lit when a hot wate r tap is open and th e water heater is operating.
50 SECTION IX: PARTS LIST TGHE-160E and TGHE-199E Models.
51 TGHE-160E TGHE -199E No. Description Quantity 001 Main Body 1 1 002 Wall Bracket 2 2 003 Rubber Bushing 1 1 004 Connection Reinforcement Panel 1 1 005 Heat Protection Plate 1 1 006 Front Panel 1 1 .
52.
53 TGHE-160E TGHE -199E No. Description Quantity 103 Burner Unit Assembly LPG 1 1 Burner Unit Assembly NG 1 1 104 Burner Case Cover 1 - 106 Burner Packing 1 - 107 Burner 16 - 108 Burner Case Back Cove.
54.
55 TGHE-160E TGHE -199E No. Description Quantity 100 Gas Controller Assembly 1 1 101 Test Port Set Screw 2 2 102 Gas Connection 3/4" NPT 1 1 400 Water Inlet 3/4" NPT 1 1 401 Water Flow Servo.
56.
57 TGHE-160E TGHE-199E No. Description Quantity 447 Connection Harness 1 1 712 Frost Sensing Switch 2 1 713 Anti-Frost Heater 120V 1 1 715 Valve Heater 120V Assembly 1 1 721 Fuse Harness 1 1 722 Power.
58 SECTION X: WARRANTY What does this Limited Warr anty Cover? This limited warranty covers b o th the heat exchanger and component parts for leakage or other malfunction caused by defects in materials and/or wo rkmanship.
59 demand recirculation is n ot incorporated. A system that incorporates a continuou s recirculation due to timer settings, excessive heat lo ss of the loop or aquastat / thermostat setting will be treated as a continuous circul ation system and hav e a reduced warranty of 3 years.
60 EverHot® Limited Warranty Registration In order to confirm Limit ed Warranty coverage at 12 year s for Residential Applications 1 , complete the information below and click submit.
61 NOTES:.
62 NOTES:.
63 NOTES:.
Ambler, PA For U.S. and Canada field service, Contact your professional installer or local Bradford White representative. Sales/ 800-523-2931 Fax/ 215-641-1670 Parts Fax/ 215-641-2180 Technical Suppor.
Ein wichtiger Punkt beim Kauf des Geräts Bradford-White Corp TGHE-199E-N(X) (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bradford-White Corp TGHE-199E-N(X) noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bradford-White Corp TGHE-199E-N(X) - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bradford-White Corp TGHE-199E-N(X) reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bradford-White Corp TGHE-199E-N(X) erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bradford-White Corp TGHE-199E-N(X) besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bradford-White Corp TGHE-199E-N(X) verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bradford-White Corp TGHE-199E-N(X). Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bradford-White Corp TGHE-199E-N(X) gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.