M OD E L G W H 2 7 0 0 E S N G an d G WH 2 7 0 0 E S LP - I N D OO R M O D E L T emper atu re Modu lat ed wit h E lec t ronic Ignit ion Suit able for heat i ng pot able w at er only Not app roved fo r.
6 720 608 542 2 Index Index 1 Warning 3 2 Appliance de tails 4 2.1 Features 4 2.2 Specification s (Technical data) 5 2.3 Unpacking th e heater 6 2.4 General rules to follow for safe operation 7 2.5 Dimensions and Minimum installation cl earances 8 3 Installation in structions 9 3.
6 720 608 542 Warning 3 1 Warning For your safe ty Do not store or use gas oline or other flammable, combustible or corrosive v apors and liquids in t he vicinity of th is or any other applia nce. Warning: Carefully pla n w here you install the heater.
6 720 608 542 4 Appliance de tails FCC: This device c omplies w ith Part 15 of th e FCC rules. Operation is subject t o the following two conditions: (1) This device may not cause harmful interference, and (2 ) this device must accept a ny interfere nce received, including interference that ma y ca use u ndesired operation.
6 720 608 542 Appliance detai ls 5 2.2 Specifications (Technical data) Approved in US/Canada Capacity Maximum flow r ate: 7.1 5 G PM (27 l/min) at a 45°F (25°C) rise. Maximum out put 160,500 B tu/h (47.0 kW) Maximum in put 199,000 B tu/h (58.3 kW) Efficiency in % Thermal eff iciency > 82% Min.
6 720 608 542 6 Appliance de tails 2.3 Unpacking the heater Before inst alling the uni t, be certai n you have the correct heate r for your type of Gas: Propane or Natural Gas. Identification labels are found on the shipping box, and on the rating p late w hich is located on the right side panel of the cover.
6 720 608 542 Appliance detai ls 7 2.4 General rules to follow for safe operation B 1. You m ust follo w these instructions when you inst all your heater. In th e United States: T he installation must conform with local co des or, in the ab sence of local codes, the Na tional Fuel Gas Code A NSI Z2 23.
6 720 608 542 8 Appliance de tails 2.5 Dimensions and Minimum installation clearances Fig. 6 Dimensions 1 On/Off b utton 2 Reset button 3 Program key 4 Power O N or stan d-by LED 5 LCD d isplay 6 Up bu tton 7 Down button Fig. 7 Minimum clea rances Note: For serv icing access, a 2ft cl earance to front cover is recomme nded.
6 720 608 542 Installation instructions 9 3 Inst allation ins truction s 3.1 Tools required for installation • Philips head sc rewdriver • Flat head screwd river • Adjustable wren ch • Level .
6 720 608 542 10 Installation ins tructions Horizontal ve nting systems onl y: An optional stainless c once ntric v ent/air intake termina- tion can be us ed to provide only one penetration poi nt through the exterior wall (see Fig. 8, 9 & 10). The con- centric vent/a ir intake kit can be ordered fro m your local wholesaler.
6 720 608 542 Installation instructions 11 Condensate drain requireme nts An exter nal condensate drain (not supplied wi th the heater) must be i nstalled unde r the following conditions: • All vertical termi nating vent installati ons.
6 720 608 542 12 Installation ins tructions Required dire ct vent terminal cl earances (twin p ipe / concentric pen etration) Fig. 11 * For clearances not specified in ANSI Z223. 1 / NFPA 54 or CSA -B149.1, one of the follo wing shall be indicated: a) A minimum cl earance value determine d by testing in accordanc e with section 2.
6 720 608 542 Installation instructions 13 Required ot her than direct v ent terminal clea rances (single pipe penetration) Fig. 12 * For clearanc es not specified in ANSI Z223.1 / NFPA 54 or CSA -B149.1, one of the follo wing shall be indicated: a) A minimum clearance value determin ed by testing in accor dance with section 2.
6 720 608 542 14 Installation ins tructions 3.3.3 Venting c onfiguration exampl es Below are appro ved e xamples of horizontal venting insta llations. Fig.
6 720 608 542 Installation instructions 15 Fig. 17 Vert ical ven ting inst allation (twin pipe pen etra- tion) Fig. 18 Vert ical venting installa tion - Masonry Chi m- ney (combust ion air piping not shown) 3.
6 720 608 542 16 Installation ins tructions 3.3.5 Condensat e drain installation Note: Do not install co ndensate drain i n areas where it may freeze. 1. Install condensate drain as close to he ater as possi- ble. 2. Use 3/8" ID high te mperature silicone tube to con- nect to conden sate drain port.
6 720 608 542 Installation instructions 17 3.3.6 Fan speed adjustment IMPORTANT! Installation adjus tment: After installin g the water heater, the fan speed v alues for minimum power (P2 ) and maximu m po wer (P1) may need adj ustment due to v ariations in a ltitude and ve nt pipe length.
6 720 608 542 18 Installation ins tructions Adjusting min imum power fan speed (P2) To select fan sp eed: B Press ON/ OFF button into O FF. B Press and h old "Prog ram" bu tton and press ON/OFF but ton to turn applia nce ON.
6 720 608 542 Installation instructions 19 Attention re sidents of the Com monwealth of Massachuse tts: In th e Commonweal th of Ma ssachusetts t he following regulation we nt into effect on 12/ 30/20.
6 720 608 542 20 Installation ins tructions 3.4 Combustion air requirements Twin pipe a nd Concentric pipe The water heater is designed as a se aled combustion appliance. It is recomme nded that the combustion air be provided f rom the outside by a dedicated pipe (twin pipe) or by connect ing to the c oncentric vent k it (see Fig.
6 720 608 542 Installation instructions 21 3.5 Proper location for installing your heater Carefully selec t the location of the water he ater. For your safety and for proper heater opera tion, you must provide co mbustion ai r to the heater and a proper exhaust vent system.
6 720 608 542 22 Installation ins tructions Fig. 25 Le veling the mounting b racket on the studs Fig. 26 Mo unting the heater 3.8 Gas pip ing & c onnecti ons Before connecting the gas supply, ch eck t he rating plate on the right side of the heate r to be sure that the heater is rated for th e sa me gas to which it will be connected.
6 720 608 542 Installation instructions 23 Once connections a re ma de, check for gas leaks at all joints. Apply some gas leak detection solution to all gas fittings. Bubbles are a sign of a leak. A combustible gas detector may also be used to dete ct for leaks.
6 720 608 542 24 Installation ins tructions FOR NA TU R AL GAS Maximum Capac ity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0 .5 Psig or less and a Pressure drop of 0.3” in Wat er Column (0.75mba r).(Based on a 0.60 Specific Gravity Gas ) Btu numbers giv en in thousands.
6 720 608 542 Installation instructions 25 3.9 Water connections B When facing th e hea ter, the ¾” cold co nnection is on the bottom right and the hot c onnection is on the bot- tom left. Centrally l ocating the water heat er is recom- mended to keep hot water distributio n times even throughout the st ructure.
6 720 608 542 26 Installation ins tructions Connecting the pressure relie f valve (PRV) A listed pressure relief v alve suppli ed with t he heater must be installed at the time of installation. No valve is to be placed between the PRV and the heater. No reducing coupling or other r estriction may be inst alled in the discharge line.
6 720 608 542 Installation instructions 27 3.12 Measuring gas pressure Confirm gas p ressure upon inst allation. Connectin g manometer B Shut off gas supply at installer supplied shutoff valve for this water hea ter. B Remove front cover and loc ate inlet gas pressure measuring point (s ee Fig.
6 720 608 542 28 Electrical conn ections 4 Electri cal conne ctions 4.1 Electrical power supply The w ater heater requires an ele ctrical power supply from a 120VAC / 60Hz properly rated receptacle and must be properl y grounded. The heater is wired as shown in the wiring diagra m (chapter 9, Fig.
6 720 608 542 Operation inst ructions 29 5 Opera tion ins tructions Fig. 38 1 On/O ff button 2 Reset button 3 Prog ram Key 4 LCD d isplay 5 Up bu tton 6 Down button 7 LED - Power On indicator o r Stand-b y 5.1 LCD Display functions Fig. 39 Pow er bar indicator Fig.
6 720 608 542 30 Operation inst ructions 5.2 For your safety read before operating your water heater A. This appliance i s equipped with electroni c ignition for lighting the ma in b urner. When turni ng the heater o n, follow these inst ructions exactly.
6 720 608 542 Operation inst ructions 31 5.5 Use of optional remote control accessory (part no. TSTAT2) Fig. 47 Remot e control The wireless remote control acc essory (Fig. 71, component 13) a nd the temperature selecto r buttons on the fr ont of the w ater he ater operate identically.
6 720 608 542 32 Maintenance and service 6 Main tenance a nd service The unit should be checked once a y ear by a gas technician. If repairs are neede d, the repairs sho uld be done by a gas technician. 6.1 Annual maintenance (To remove front cover, see page 6.
6 720 608 542 Maintenance a nd service 33 space whic h is likely t o e xperience fre ezing temperatures, all water m ust be dr ained from the heater. If precauti ons are not taken, re sulting damage w ill not be covere d under the wa rranty.
6 720 608 542 34 Maintenance and service Static Gas Press ure: “ WC P1 Operating Pressure: “ WC The P1 minimum operating gas pressu re is 3.5" WC for Natural Gas a nd 8" WC for Prop ane. Do not proce ed in adjusting CO 2 until press ure is at or above these levels, but not to exce ed 10.
6 720 608 542 Maintenance a nd service 35 Final Read ings P2 CO 2 Reading: % CO 2 P1 CO 2 Reading: % CO 2 Fig. 57 Ad justing P1 CO 2 level Fig. 58 Ad justing P2 CO 2 level CO 2 range (%) Max. CO level (measured) Nat. Gas max. input P1 7.5 % - 8.1 % < 250 ppm min.
6 720 608 542 36 Maintenance and service 6.5 Program values This section describes details on programming the appliance. For most applications the factory defaul t values will robust and s table ope ration. Only adjust the factory setti ngs if the installation requires changes as indicated in t he appropriate sect ion of this manual.
6 720 608 542 Maintenance a nd service 37 6.6 Control board diagnostics 1. Turn on/of f switch on w ater heater to off (O) position. 2. Press and hold t he program ( ) button whi le turning the on/off swi tch to the on (I) po sition. T he display w ill cyc le throug h a startup procedur e including the sof tware version.
6 720 608 542 38 Troubleshoot ing 7 Troub leshootin g 7.1 Introduction Many of the q uestions customer s ask regarding operation o f this uni t can be a nswered by following the troubleshooti ng steps as ou tlined below. Visit our web site at www.bo schhotwater.
6 720 608 542 Troubleshooti ng 39 heater. Then open all of the hot water taps served by the heater. Wait 10 minutes and che ck all t aps for water flow. There should be no wa ter flowing. Any continuous flow o f wa ter, s mall or large, indicates a crossover and must be corrected.
6 720 608 542 40 Troubleshoot ing 5. Lac k of adeq uate ga s pre ssure. In adequate gas pressure wil l cause the fuel-to-air mixtu re (CO 2 ) to be out of adjustment. This will re sult in u nstable burn er flames and noise. Ensure gas pre ssure is in accordance with spe cifications in section 3.
6 720 608 542 Problem sol ving 41 8 Pro blem solvi ng 8.1 Error code diagnostics i To remove error code from the display, press t he reset button. Display Caus e Solution Fault in the flue gas limiter. 1. Check continuity of the flue gas limiter (see Fig.
6 720 608 542 42 Problem solvin g (Flashing) Out let temperature senso r not sensing expected o utput temperature. 1. Check that the s ensor is firmly attached to the hot water pipe (see Fig. 70 , page 55 ). 2. Clean inlet f ilter screen and clear any debris out of shower heads, faucet aerators and whole house filters.
6 720 608 542 Problem sol ving 43 Over-temperature detected by outlet temperature sensor o n hot water pipe. Temperature > 185 °F 1. C heck that the senso r is firmly a ttached to the vertica l section of the hot water pipe (see Fig. 70 , page 55 ).
6 720 608 542 44 Problem solvin g No flame ionization detected with water flow. 1. Verify that all manual gas shut off valves are open. 2. Check gas type, see Fig. 2 , page 6 . 3. Reset error code and open a water tap to cycle the heater in an effort to purge air on new i nstallations.
6 720 608 542 Electrical dia gram 45 9 Elect rical diagr am Fig. 59 Ele ctrical scheme 1 Intlet w ater temp erature s ensor 2 Outlet water temp erature se nsor 3 Backfl ow temper ature sen sor 4 Casca.
6 720 608 542 46 Sensor resist ance charts 10 Sensor r esistance charts Fig. 60 Fig. 61 Out let t e mperature s enso r cha racteri sti cs 3 2 3 7 4 2 4 7 5 2 57 6 2 6 7 7 2 77 8 2 8 7 9 2 9 7 10 2 10 .
6 720 608 542 Sensor re sistance charts 47 Fig. 62 Bac k Fl ow characteri sti cs 3 2 3 7 4 2 4 7 5 2 5 7 6 2 6 7 7 2 7 7 8 2 8 7 9 2 9 7 10 2 10 7 112 117 12 2 12 7 13 2 13 7 14 2 14 7 15 2 15 7 16 2 .
6 720 608 542 48 GWH 2700 E S Functional schem e 11 GWH 270 0 ES Fun ctional sch eme Fig. 63 Func tional scheme.
6 720 608 542 Interior compon ents diagram and parts list 49 12 Interior componen ts diagr am and p arts list 12.1 Interior components Fig. 64 C omponents 1 Flue ga s collec tor 2 Heat exchanger 3 Fla.
6 720 608 542 50 Interior compon ents diagram and parts list Fig. 65 Applia nce overview.
6 720 608 542 Interior compon ents diagram and parts list 51 12.2 Components diagram 12.2.1 Group 1 Fig. 66 C omponents Diagram 9 9 8 5 1 2 3 6 7 9 10 12 9 14 16 17 11 13 15 15 4 6720902973.
6 720 608 542 52 Interior compon ents diagram and parts list 12.2.2 Group 2 Fig. 67 Comp onents Diagram 1 3 2 4 5 6 7 8 9 672 0902974 .AA JF Item Description Reference 1 Heat exc hanger 8 705 406 422 .
6 720 608 542 Interior compon ents diagram and parts list 53 12.2.3 Group 3 Fig. 68 C omponents Diagram 15 14 1 3 4 6 7 8 2 12 9 11 13 16 17 5 672 09029 75.
6 720 608 542 54 Interior compon ents diagram and parts list 12.2.4 Group 4 Fig. 69 Comp onents Diagram 9 2 14 1 3 4 5 6 7 8 11 11 12 13 10 6720608158-73.
6 720 608 542 Interior compon ents diagram and parts list 55 12.2.5 Group 5 Fig. 70 C omponents Diagram Item Description R eference 1 Wate r valve w ith engine 8 708 505 024 2 O-rin g 8 700 205 147 3 .
6 720 608 542 56 Interior compon ents diagram and parts list 12.2.6 Group 6 Fig. 71 Comp onents Diagram 15 1 2 3 7 6 9 5 11 13 16 14 10 12 8 4 6720 90297 8.AA JF Item Descrip tion R eference 1 Cont rol unit 8 70 7 207 2 57 2 Fuse T2.5A 1 904 52 1 342 3 Fuse T1.
6 720 608 542 Protecting the environment 57 13 Protectin g the en vironmen t Packing The p acking box may be fully re cycled as confirmed by the recyclin g symbol . Componen ts Many parts in the heater can be fully re cycled in the end of the product life.
6 720 608 542 58 Limited War ranty 14 Limited Warranty General Aquastar w ater heaters are warra nted by th e Manufacturer (BOSC H) through Bosch Thermotechnolo gy Corp.
6 720 608 542 Limited Wa rranty 59.
6720608542 © 200 9 Bosch Thermotechnology Corp ., Londonderr y, N H a ll rights reser ved Replac ement Pa rts available from : Bos c h T ermotecnologia SA Estrada de C acia 38 0 1 - 856 Aveiro - PO RTU GAL BOSCH THERMOT ECHNOLOGY CO RP. 50 Wentworth Avenue Londonderry, NH 03053 Tel.
Ein wichtiger Punkt beim Kauf des Geräts Bosch GWH 2700 ES LP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bosch GWH 2700 ES LP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bosch GWH 2700 ES LP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bosch GWH 2700 ES LP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bosch GWH 2700 ES LP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bosch GWH 2700 ES LP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bosch GWH 2700 ES LP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bosch GWH 2700 ES LP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bosch GWH 2700 ES LP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.