663 OWNERS MANUAL for SA TELL ITE COFFEE BREWER wit h ELECTRO-MECH ANICA L CONTROL and EXTERNALLY HEATED SATELLITE SERVER MODEL : 9102A 9104A Includes: Installation Operation Use & Care Servicing Instructio ns Model 9102A Satellite Brewer with 9105SS Satellite PRINTED IN UNITED STATES OF A MERIC A p/n 76061 Rev.
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS Thank You for pu rchasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D O P E R AT I N G CO N T R O L S 2 Fig 1. SS-1 Satellite Brewing System Features & Operating Controls 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
FEATURES AND OPER ATING CONTROLS (continued) Brewer Adjustable Legs Connector Hot W ater Faucet Name plate Control Panel Start Brew Sw itch Ready to Brew Indicator Stop Brew Swit ch War me r Sw itch T.
This appliance is inten ded for use in commer cial establishmen ts only. This appliance is inten ded to brew hot beverage, specif ically coffee, for human consumption.
5 INSTALLATION INSTRUCTIONS INSTALL LEGS The brewer is provided with adjustable legs. Be sure all f our legs are securely screwed into the base of the brewer.
INSTALLATION INSTRUCTIONS (continued) 6 CA UTIO N: Electric Shock Hazard Brewer must be properly grounded to a reliable earth ground to prevent p ossible shock hazard. Do not assume a plumbing line will provide such a ground. Electrical shock may cause serious injury.
7 OPERATING INSTRUCTIONS Fig. 5 Control Panel Fig. 6 Brew Basket IMPORTANT: To avoid overflows, DO NOT start the brew cycle unless an EMPTY satellite is in place under the brew chamber. NOTE: The brew can be cancelled at any time by pressing the STOP sw it ch.
OPERATING INSTRUCTIONS (continued) 8 Fig. 7 W ater Fl ow Diagr am BREW & BY P ASS This brewer is a standard displacement brew er with pour-over optio n.
9 CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Turn POWER SW ITCH OFF. Allo w brewer to cool. FREQUENCY: Dail y TOOLS: Mild Detergent, Clean So ft Cloth or S ponge Bristle Brush 1. Turn POWER SWITCH OFF . Allow brewer to cool.
10 CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean Satellite PRECAUTIONS: Drain Satellite before Cleaning FREQUENCY: T wice Weekly TOOLS: Sight Glas s Brush, Sanitizer Soft Clean Cloth, Bucket 1. Remove and drain satellite. 2. Place 1 packe t of Sanitize r into 2-1/ 2 gallons of warm tap water.
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Will not heat or brew (no lights) Brewer not plugg ed in or circuit breaker tripped Reconnect brewer to electric power Reset circuit break er Main power switch off or damag ed Che ck.
12 SERVICING IN STRUCTIONS CA UTION : SHOCK HAZARD Disconnect brewer from electric power before opening any access panel. Note position of any wires or hoses before removing them from a panel. Wrench for Faucet Tubing ACCESS PANELS TOP PANEL is attached with two screws at the rear and a lip at the front.
13 CAUTION: SHOCK HAZARD Live electrical circuits are exposed during this procedure. Use care to avoid uninsulated electrical connectors. Adjustments to be performed by qualified technician only. NOTE: 1/8 turn = approx 10ºF (5.5ºC) TEMPERATURE A DJUSTMENT PRECAUTIONS: Disconnect br e wer from electric power.
SERVICING IN STRUCTIONS (continued ) 14 Adjustm ents to be perform ed by qualified te chnic ian only. NOTE: Brewer is pre-adjusted to deliver 1/2, 1 and/or 1-1/2 gallons of coffee at a wate r pressure of 50 p.s.i. Use this procedure to adjust the delivered volume to suit local conditions.
SERVICING INSTRUCTIONS (continued) 15 CA UTION : SHOCK HAZARD Disconnect brewer from electric power before opening the top panel. The bre wer is shipped f rom th e fact or y pre-set f or 25% bypass. This adjus tment mu st never be made unless the br ewer is installed on a soft w ater li ne, or a change in coffee strength is required.
CA UTIO N: CH EMICA L BURN HA ZA RD Deliming chem icals are caustic. W ear ap pr op riate pr ote ct ive gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th . This operation should only be perfo rm e d by qualifie d an d ex- perienced service personnel.
SERVICING INSTRUCTIONS (continued) 17 10. Reinstall tank lid assembl y into hot w ater tank. Make sure th e lid gasket is properly in place, then reinstall the hold- dow n clamp. 11. Remove spray disks and gaskets. Rinse both brew heads w ith clean water.
EXPLODED VIEW 18 PLUMBING COMPONENTS 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
EXPLODED VIEW (continued) 19 ELECTRICAL COMPONENTS 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
EXPLODED VIEW ((continued) 20 CABINET & RELATED COMP ONENT S 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
EXPLODED VIEW (continued) 21 SATELLITE A SSEMBLY 9105SS 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
22 SERVICE KITS 663 76061 Owners Manual for 9102A Single Satellite Bre wer F AUCET REP AIR COMPONENTS 8268 0 Hex L o ck Nu t 85 5 1- 1 00 B 7 /1 6“ Lo ck Washe r 8268 1 Wash er 8255 6 Fauc et A ssem.
23 WIRING DIA GRAMS 663 76061 Owners Manual for 9102A Single Satellite Bre wer.
Blo omfi eld In dus trie s, Inc. Divisio n of Carri er Com m erci al Refrigerat i on In US and Canada T elephone: 775 -698- 5700 Fa x: 8 88 -492 -278 3 Fa x: 8 00 -356 -514 2 () website: www .
Ein wichtiger Punkt beim Kauf des Geräts Bloomfield 9104A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bloomfield 9104A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bloomfield 9104A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bloomfield 9104A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bloomfield 9104A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bloomfield 9104A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bloomfield 9104A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bloomfield 9104A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bloomfield 9104A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.