RS-232 ↔ RS-422 INTERF ACE CONVER TER 1 FEDERAL COMMUNICA TIONS COMMISSION AND INDUSTR Y CANADA RADIO FREQUENCY INTERFERENCE ST A TEMENTS This equipment generates, uses, and can radiate radio-freque.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 2 INSTRUCCIONES DE SEGURIDAD (Normas Oficiales Mexicanas Electrical Safety Statement) 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 3 TRADEMARKS USED IN THIS MANUAL Any trademarks mentioned in this manual are acknowledged to be the pr operty of the trademark owners.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 4 Contents Chapter Page 1.Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. Introduction . . . . . . . .
RS-232 ↔ RS-422 INTERF ACE CONVER TER 5 1. Specifications Speed — 64,000 bps, max. Connectors — RS-232 port: DB25 female; RS-422 port: DB37 female Indicators — 7 LEDs show status of RS-232 and RS-422 signals and indicate power ON.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 6 2. Introduction The RS-232 ↔ RS-422 Inter face Converter provides bi-directional synchronous or asynchronous conversion of all commonly used RS-232 and RS-422 signals.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 7 1. The Converter does not require special handshaking signals in order to operate. 2. The Converter should always be configured the opposite of the equipment it’ s connected to if straight-through cabling is used.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 8 3. Installation T o connect the Converter to your devices, follow these steps: 1. Attach the cable from the RS-422 device to the 37-pin female receptacle on the rear panel of the Converter . 2. Attach the cable from the RS-232 device to the 25-pin female receptacle on the rear panel of the Converter .
RS-232 ↔ RS-422 INTERF ACE CONVER TER 9 Figure 3-1. Board Layout Showing Component Locations. (Dashed Lines show DTE/DCE DIP Shunt Locations.) AC POWER CONNECTOR RS-422 CONNECTOR RS-232 CONNECTOR DI.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 10 Figure 3-2. Sample DIP-Shunt Setting. Figure 3-2 shows the DIP-shunt settings used for an application like the one illustrated in Figure 3-3a. NOTE The filled-in rectangles in Figure 3-2 indicate the jumpers that contain a DIP-shunt.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 11 Figures 3-3a and 3-3b show some typical synchronous applications. Figure 3-3. Synchr onous Applications. Applications involving asynchronous devices are also possible. Figure 3-4 illustrates a popular asynchronous setup, while Figure 3-5 shows the cabling involved.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 12 T HE R ECEIVER T ERMINA TION S WITCH This switch is marked S1 on the printed circuit-board diagram in Figures 3-1 and 3-2. This switch ser ves to terminate the receiver with pull-up and pull-down resistors in order to designate the receiver state and enable the Converter’ s anti-streaming function.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 13 Figure 3-5. Signal Flow Diagram A. RS-232 (Port is DTE) RS-422 (Port is DCE) 12 Terminal Ready A (-) 30 Terminal Ready B (+) DTR 20 CR8 (RS-422 DSR LED) 11 2.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 14 Figure 3-6. Signal Flow Diagram B. RS-232 (Port is DCE) RS-422 (Port is DTE) 12 Terminal Ready A (-) 30 Terminal Ready B (+) DTR 20 CR8 (RS-422 DSR LED) 11 2.
RS-232 ↔ RS-422 INTERF ACE CONVER TER 15 4. Ground Strap and Inter face Pinouts Signal grounds (Pins 19, 20, and 37 on the RS-422 inter face and Pin 7 on the RS-232 inter face) are connected together , but not connected to chassis ground (Pin 1).
1000 P ark Drive • Lawrence, P A 15055-1018 • 724-746-5500 • F ax 724-746-0746 © Copyright 1998. Black Box Corporation. All rights reserv ed..
Ein wichtiger Punkt beim Kauf des Geräts Black Box RS-422 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Black Box RS-422 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Black Box RS-422 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Black Box RS-422 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Black Box RS-422 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Black Box RS-422 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Black Box RS-422 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Black Box RS-422. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Black Box RS-422 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.