Benutzeranleitung / Produktwartung IC478A-F-R2 des Produzenten Black Box
Zur Seite of 25
CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.
1 ASYNC 2 3 2 ↔ 422/485 CONVERTER FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.
2 ASYNC 232 ↔ 422/485 CONVERTER NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD ..
3 ASYNC 2 3 2 ↔ 422/485 CONVERTER.
4 ASYNC 232 ↔ 422/485 CONVERTER Contents.
5 Data Rate Connectors Transmission Format Transmission Line Transmission Mode Range Control Signals Carrier Surge Protection RTS/CTS Delay MTBF Operating Temperature CHAPTER 1: Specifications 1.
6 ASYNC 232 ↔ 422/485 CONVERTER Humidity Altitude Power Size Shipping Weight.
7 CHAPTER 2: Introduction ↔ Section 4.4 2. Introduction.
8 ASYNC 232 ↔ 422/485 CONVERTER ↔ DCE DTE +RCV -G-XMT+ 3. Configuration DTE/DCE Switch Terminal Block.
9 3.1 Setting the DTE/DCE Switch ON 1 2 3 4 5 6 7 8 CHAPTER 3: Configuration DIP Switch S1.
10 ASYNC 232 ↔ 422/485 CONVERTER 3.2 DIP-Switch Configuration internally ON OFF ON 1 2 3 4 5 6 7 8.
11 CHAPTER 3: Configuration 3.2.1 DIP-S WITCH S ETTINGS Switch S1 Summary Table Position Function Factory Default S1-1* “Transmit Off” Impedance Off High Z S1-2* “Transmit Off” Impedance Off S1-3 RTS/CTS Delay On 8 msec.
12 ASYNC 232 ↔ 422/485 CONVERTER S1-4: Echo Mode S1-5: Carrier-Control Method NOTE Carrier is ON when RTS is asserted positive, and OFF only when RTS is driven to a negative voltage.
13 CHAPTER 3: Configuration 3.2.2 C ONFIGURATION S WITCH A PPLICATIONS Do not change switch settings until you have carefully read this manual. Typical Switch Applications Switch Settings Point-to-Point Multipoint 4W 4W HDX 2W 4W 2W “Xmt Off” Imp.
14 ASYNC 232 ↔ 422/485 CONVERTER 4.1 Connection to the RS-485 Interface must 4.1.1 4-W IRE C ONNECTION U SING THE DB25 (IC477A-X-R2 AND IC478A-X-R2) Converter RS-485 (530) Device Signal DB25 Pin DB25 Pin Signal XMTA 2................................
15 CHAPTER 4: Installation 2) It is not necessary that the RS-485 device adhere to the RS-530 standard. However, you must make sure that the signals, polarities, and pairing of your connection conform to this table.
16 ASYNC 232 ↔ 422/485 CONVERTER 5. the other pair of wires NOTE Positive and negative are relative terms and may not always have the same relationship for all RS-422 or RS-485 devices (see the previous note regarding “flipping the leads”). Converter RS-485 Device XMT+ .
17 8. 9. +RCV -G-XMT+ +RCV -G-XMT+ +RCV -G-XMT+ CHAPTER 4: Installation.
18 ASYNC 232 ↔ 422/485 CONVERTER 10. 11. 4.1.3 2-W IRE C ONNECTION only the transmit (XMT) pair Converter Signal RS-485 Signal XMT+ .................
19 CHAPTER 4: Installation 4.2 Connection to the RS-232 Interface NOTE If you must use a cable to connect the Converter to the RS-232 device, make sure it is a straight-through cable of the shortest possible length. We recommend no more than 6 ft. (1.
20 ASYNC 232 ↔ 422/485 CONVERTER 4.4 Operation data.
21 APPENDIX A: RS-232C Pin Configurations ST ANDARD “DTE” SETTING DIRECTION DIRECTION From Converter Data T erm. Ready (DTR) - 20 1- (FG) Frame Ground 2- (TD) T ransmit Data 3- RD) Receive Data 4-.
22 ASYNC 232 ↔ 422/485 CONVERTER Pin Number Pin Name Appendix B . 422/485 (530) Pin Configuration.
23 APPENDIX C: Self-Test Section 3.2.2 Appendix C. Self- T est.
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 1998. Black Box Corporation. All rights reserved..
Ein wichtiger Punkt beim Kauf des Geräts Black Box IC478A-F-R2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Black Box IC478A-F-R2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Black Box IC478A-F-R2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Black Box IC478A-F-R2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Black Box IC478A-F-R2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Black Box IC478A-F-R2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Black Box IC478A-F-R2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Black Box IC478A-F-R2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Black Box IC478A-F-R2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.