technic al guide W a t e r S o u r c e He at P umps.
2 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Johnson Controls 3 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) INTR ODUCTION Performance and dependability in a no-nonsense heat pump.
4 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps SPECIFICA TIONS GENERAL All R-series models ½ - 6 ton ship as factory-charged packages, complete with R-410A refrigerant. Horizontal (RSH) units are designed for suspended ceiling mount- ing.
Johnson Controls 5 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) NOMENCLA TURE WA TER SOUR CE HEA T PUMP Product Category RS = Water-Cooled HP R-410A Product Indentifier V = Vertical A.
6 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PHY SICAL D A T A Model Series 007 009 012 018 024 030 036 042 048 060 070 Nominal Cooling (T on) 1 0.5 0.75 1.0 1.5 2.0 2.5 3 3.5 4 5 6 Compressor-T ype Rotary Reciprocating Scroll Air Coil-T ype Enhanced Copper tubes, Enhanced Aluminum Fins Face Area(sq ft) 1.
Johnson Controls 7 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) ARI/ISO PERFORMANCE D A T A PERFORMANCE D A T A - ARI/ISO 13256-1 WA TER LOOP CONDITIONS* Unit Model Flow Rate (USGPM) Air Flow (SCFM) Cooling Capacity (Btuh) EER Heating Capacity (Btuh) COP 007 1.
8 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*007 — 320 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 1.8 4.8 1 1.0 4.1 0.44 2.6 80 2.7 30 1.0 2.1 4.9 8.
Johnson Controls 9 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*009 — 320 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 2.4 7.0 16.1 5.6 0.57 3.7 84 2.9 30 1.2 2.6 6.0 12.
10 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*012 — 400 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 3.0 3.9 9.0 8.2 0.86 5.3 87 2.8 30 1.5 2.0 4.5 16.
Johnson Controls 11 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*018 — 640 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 4.8 8.4 19.4 10.4 1.09 6.7 83 2.8 30 2.4 3.1 7.1 26.
12 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*024 — 800 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 6.0 9.7 22.4 13.3 1.50 8.2 83 2.6 30 3.0 3.4 7.9 35.
Johnson Controls 13 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*030 — 1000 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 7.8 7.8 18.0 17.5 1.97 10.8 84 2.6 30 3.9 4.2 9.
14 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*036 — 1200 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 9.0 10.1 23.3 19.9 1.94 2.0 83 3.0 30 4.5 3.4 7.
Johnson Controls 15 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*042 — 1400 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 10.4 12.3 28.4 26.7 3.32 15.4 86 2.5 30 5.2 4.1 9.
16 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*048 — 1600 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 12.0 15.1 34.9 30.5 3.32 19.1 86 2.8 30 6.0 4.4 10.
Johnson Controls 17 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*060 — 2000 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 15.0 17.8 41.1 38.2 3.32 26.8 86 2.9 30 7.5 5.9 13.
18 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*070 — 2200 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 17.5 20.8 48.0 42.1 3.32 30.7 86 2.6 30 8.8 8.3 19.
Johnson Controls 19 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) CORRECTION F ACT ORS ANTIFREEZE CORRECTION T ABLE Antifreeze Concentration 5% 10% 15% 20% 25% 30% 40% Ethylene Glycol Cooling 0.998 0.995 0.993 0.991 0.989 0.987 0.984 Heating 0.
20 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps BL O WER PERFORMANCE BLO WER PERFORMANCE Unit Size Rated CFM Min. CFM Max.
Johnson Controls 21 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) ELECTRICAL D A T A RSH/RSV ELECTRICAL D A T A Unit Size SUPPL Y VOL T AGE COMPRESSOR BLOWER MIN. CCT . AMP ACITY MAX FUSE / CCT . BKR. AMP QTY RLA LRA HP FLA 007 208-230/1/60 1 @ 3.
22 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps D A B E C G 1.50" J 2.00" K L 1.63" M 3/4 FPT DRAIN W A TER IN W A TER OUT SUPPL Y AIR AIR RETURN 0.
Johnson Controls 23 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) A C K L 2 1" G D G F E G D G F E SERVICE DOORS 1 - ELECTRICAL BOX SERVICE DOOR 2 - COMPRESSOR AND C ONDENSER SERV.
24 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps WIRING DIA GRAM SINGLE PHASE RS* UNITS: 208-230V/1Ph/60Hz 265V/1PH/60Hz.
Johnson Controls 25 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) WIRING DIA GRAM 3 PHASE RS* UNITS: 208-230V/3Ph/60Hz 460V/3Ph/60Hz 575V/3Ph/60Hz.
26 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps NO TES.
Johnson Controls 27 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) NO TES.
Printed on recycled paper T echnical Guide: YK145.00-EG4 (309) Supersedes: Nothing © 2008 Johnson Controls, Inc. P .O. Box 423, Milwaukee, WI 53201 Printed in USA www .
Ein wichtiger Punkt beim Kauf des Geräts York YK145.00-EG4 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie York YK145.00-EG4 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für York YK145.00-EG4 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von York YK145.00-EG4 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über York YK145.00-EG4 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon York YK145.00-EG4 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von York YK145.00-EG4 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit York YK145.00-EG4. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei York YK145.00-EG4 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.