ADD - ON COILS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T PUMPS MODELS: MC , PC, FC, HD, HC, UC 600 - 2000 CF M 1.5 - 5 TON COILS Due to continuous product improvement, specifications are subject to change without notice. Vis it us on the web at www.
258931-BTG-A-0606 2 Unitary Products Group COOLING CAP ACITY - Coi l Only * Model Ra ted CFM Entering Air ° F (Wet Bulb) MBH @ Evapor ator T em peratur e and Cor respo nding Pre ssure ° F / PSIG 35 / 61.5 40 / 68. 5 45 / 76.0 50 / 84.0 UPFLOW " A" TYP E FC18A PC18A 675 72 25.
258931-BTG-A-0606 Unitary Products Group 3 COOLING CAP ACIT Y - COIL ONL Y * Model Coi l Rated C FM Enteri ng Air °F (Wet Bulb) MBH@ Evapo rator T empe ratur e and C orresp ondi ng Pr essur e °F / P SIG 35 / 6 1.5 40 / 6 8.5 45 / 7 6.0 50 / 8 4.0 FULL- CASED “A” TYPE MUL TI-POSITI ON MC18A 550 72 25.
258931-BTG-A-0606 4 Unitary Products Group Notes: • MC coils availab le with a facto ry installed horizontal d rain pan option (H). COOLING CAP ACITY - Coi l Only * MODEL RATE D CFM ENTER ING AIR ° F (Wet Bulb) MB H @ Ev apo rator T empe rature and Co rres po ndin g P ressure °F/ PSI G 35 / 61.
258931-BTG-A-0606 Unitary Products Group 5 NOTE:Do not exceed minim um/maximum CF M limits shown u nder Air Flow Data. APPLICA TION LIM IT A TION S These uni ts m ust be install ed in accorda nce with all n ation al and local s afety co des.
258931-BTG-A-0606 6 Unitary Products Group ST A TIC PRE SSURE VS . AIRFLOW (BASED O N WET COIL) UPFLOW CASED "A" TYPE Model Airflow Wet Coil FC18A PC18 A 600 0.16 800 0.23 1000 0.30 FC18B PC18 B 600 0.14 800 0.20 1000 0.26 FC24A PC24 A 600 0.
258931-BTG-A-0606 Unitary Products Group 7 CASED "A" TYP E MUL TI -POSITIO N Model Airflow Wet Coil MC18A 600 0.2 2 800 0.2 9 1000 0.36 MC18B 600 0.2 0 800 0.2 6 1000 0.32 MC24A 600 0.2 1 800 0.2 7 1000 0.33 MC24B 600 0.1 9 800 0.2 4 1000 0.
258931-BTG-A-0606 8 Unitary Products Group PHYSICAL DA T A CASED (FC) AND P AR TIAL CASED (PC) UPFLOW “A” TYPE Model App licatio n Refrig. Conn. T ypes Face Area (Sq. F t.) Rows Deep Fin Per In. Coil Si ze T ube Geome try T ube Dia. Fin T ype TXV Opera ting Weight (Lbs.
258931-BTG-A-0606 Unitary Products Group 9 HORIZONT AL - DUCT TYPE Model App licatio n Refrig. Conn. T ypes Face Area (Sq. F t.) Rows Deep Fin Per In. Coil Si ze T ube Geome try T ube Dia. Fin T ype TXV Opera ting Weight (Lbs.) HD24A3 XH1 Cooling / Heat Pump Sweat 3.
258931-BTG-A-0606 10 Unitary Products Group FULL CASED “A” TYPE MUL TI-POSITION Model App licatio n Refrig. Conn. T ypes Face Area (Sq. F t.) Rows Deep Fin Per In. Coil Si ze T ube Geome try T ube Dia. Fin T ype TXV Opera ting Weight (Lbs.) MC18A3 XH1 Cooling / Heat Pump Sweat 3.
258931-BTG-A-0606 Unitary Products Group 11 DIMENSIO NS Coil - MC Dimensions - MC Coils Model A B C D Refrige rant Line S ize * * Refrigerant line sizes may re quire larger lin es for extende d line lengths . See Y ork bulletin #690.01-AD1V for details.
258931-BTG-A-0606 12 Unitary Products Group Coil - PC Dimensions - PC Coils Model A B C D Refriger ant Line S ize * * Refrigerant line sizes may re quire larger lin es for extende d line lengths . See Y ork bulletin #690.01-AD1V for details. Facto ry Installed TXV (R22) Liquid Vapor PC18A2AN1 14.
258931-BTG-A-0606 Unitary Products Group 13 COIL - HD 1-3/4 C 5-5/8 B A D 3-3/4 2-5/8 1-3/8 VAPOR CONN. LIQUID CONN. 3/4 MPT SECONDARY DRAIN CONN. 3/4 MPT PRIMARY DRAIN CONN.
258931-BTG-A-0606 14 Unitary Products Group NOTES.
258931-BTG-A-0606 Unitary Products Group 15 NOTE S.
Subjec t to cha nge w ithou t notice. Printed in U. S.A. 258931 -BTG-A -0606 Copy right © by Y ork In ternatio nal C orp. 200 6. All rights reserve d.
Ein wichtiger Punkt beim Kauf des Geräts York FC (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie York FC noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für York FC - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von York FC reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über York FC erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon York FC besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von York FC verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit York FC. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei York FC gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.