GENERAL These completely assembled indoor units include a well- insulated cabinet, a copper tube/aluminum fin coil, throw - away filters, a centrifugal blower , a blower motor , an adjust - able V -belt drive, a blower motor contactor and a small holding charge of an inert gas.
035-09651-001-A-0304 2 Unitary Products Group T ABLE OF CONTENTS GENERAL ............................................................................. 1 REFERENCE ............................................................................. 1 INSPECTION .
rate request for inspection by the carrier's agent should be made in writing. LIMIT ATIONS These units must be installed in accordance with all national and local safety codes. If no local codes apply , installation must conform with the appropriate national codes.
035-09651-001-A-0304 4 Unitary Products Group FIG . 1 - UNIT SUSPENSION MOUNTING (Horizontal Application) Model Power Supply V oltage V ariation 1 Supply Air CFM Entering Air T emperatures, ° F Cooling - wb Heating - db Min. Max. Min. Max. Min. Max. Min.
WARNING: Do not permit overhanging structures or shrubs to obstruct air discharge. Additional height may be required for snow clearance if winter operation is expected.
Form 035-16650-001 – Supply Air Plenum Form 035-16621-001 – Return Air Grille Form 035-16632-001 – Base The supply air plenum and the return air grille should be used in lieu of ductwork only when a free blow/free return application is practical.
A 7/8" OD drain connection extends through right hand side of cabinet. Refer to Fig. 7 for recommended drain piping. The drain connection is located on the same side of the unit as the refrigerant connections. The line should be insulated where moisture drippage will be objectionable or cause damage to the area.
035-09651-001-A-0304 8 Unitary Products Group FIG . 9 - HOLE LOCA TIONS FOR PRESSURE DROP READINGS FIG . 10 - PRESSURE DROP ACROSS A DRY INDOOR COIL VS. SUPPL Y AIR CFM RPM CFM ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW F3EH090 (60 Hz) 2400 2700 3000 3300 3600 600 0.
035-09651-001-A-0304 Unitary Products Group 9 Model Accessory S tatic Resistance, IWG BLOWER CFM 2400 2700 3000 3300 3600 F3EH090 Electric Heat 10 KW 0.01 0.01 0.01 0.02 0.02 16 KW 0.01 0.02 0.02 0.03 0.04 26 KW 0.03 0.04 0.05 0.06 0.07 36 KW 0.05 0.07 0.
POWER AND CONTROL WIRING Install electrical wiring in accordance with the latest National Electrical Code (NFP A S tandard No. 70) and/or local regula - tions.
035-09651-001-A-0304 Unitary Products Group 11 FIG .12 - UNIT DIMENSIONS & CLEARANCES (F3EH090 & F4EH120) All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. ACCESSORIES • ELECTRIC HEA TER - Add 14-1/4" to unit height when used.
SECURE OWNER'S APPROV AL: When the system is functioning properly , secure the owner's approval. Show him the location of all disconnect switches and the thermostat.
Ein wichtiger Punkt beim Kauf des Geräts York F3EH090 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie York F3EH090 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für York F3EH090 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von York F3EH090 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über York F3EH090 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon York F3EH090 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von York F3EH090 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit York F3EH090. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei York F3EH090 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.