Benutzeranleitung / Produktwartung PR1145 des Produzenten Yeoman
Zur Seite of 23
Y eoman Exe Midi Conventional Flue Coal Effect Stove With upgradeable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) PR1 145 Issue 1 (July 2010) IMPORTANT This product contains a Heat resistant glass panel.
2 CONTENTS COVERING THE FOLLOWING MODELS: YM-N9171FL / YM-N9171LC YM-P9171FL / YM-P9171LC PAGE APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 9 Technical Specificati.
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 1.7 The manufacturer considers the full outer casing of this stove to be a working surface which becomes hot when the stove is lit. A suitable guard is recommended to protect young children, the aged and the infirm. 1.8 This stove must only be operated with the door secured firmly in position.
5 2. LIGHTING THE STOVE 2.1 The control valve is on the right-hand side at the foot of the stove. It has two controls: — The right-hand knob controls the pilot ignition — The left-hand knob controls the main burner 2.2 Refer to separate instructions if your stove is upgraded to include battery remote control.
6 5. CLEANING THE STOVE Advice on Handling and Disposal of Fire Ceramics 5.1 The fuel effect logs and embers in this stove are made from Refractory Ceramic Fibre (RCF).
7 HEADING 6. FUEL BED ARRANGEMENT 6.1 Place the flame baffle onto the burner and push against the rear tray lip (see Diagram 5). AR0359 5 Spacer brackets 6.2 Locate the rear panel against the spacer brackets (see Diagram 3) and slide down so that it locates on the ledge of the flame baffle (see Diagram 6).
8 AR0364 11 6.8 Replace the glass frame using the 6 x frame fixing screws (see Diagram 4) and close door. 7. GAZCO FLUE SURE SYSTEM The stove is fitted with the Gazco Flue Sure System, which will act to cut off the gas supply to the burners in the event of incorrect operation of the flue.
9 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Covering the following models: Yeoman Exe Midi YM-N9171FL / YM-N9171LC YM-P9171FL / YM-P9171LC 1 x Stove 1 x Flue infill plate 1 x Front coal 1 x Fl.
C A B A = 643mm B = 43mm C = 12mm AR0604 1 4.2 This appliance must not be installed in a room that contains a bath or shower. 4.3 The stove is not suitable for installation against a combustible wall; all combustible materials must be removed from the area behind the stove.
11 2.7 The stove is fitted with the Gazco Flue Sure System , which will act to cut off the gas supply to the appliance in the event of incorrect operation of the flue. If the system acts to shut off the gas supply, this indicates that there is insufficient flue pull.
12 3.5 Check the pull of the flue system by applying a lighted smoke pellet to the flue system opening. If there is a definite flow into the chimney, proceed with the installation, if not warm the chimney for a few minutes. IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE.
13 AR0360 8 4.8 Place the log retainer in the two guides as shown in Diagram 9. AR2076 9 FOR CLARITY, THE FOLLOWING LOG ARRANGEMENT DIAGRAMS DO NOT INCLUDE ILLUSTRATION OF THE RETAINER. 4.9 Locate the front coal between the heat shield and the flame baffle so that the ends sit flat against the burner skin (see Diagram 10).
14 INSTALLATION INSTRUCTIONS COMMISSIONING 1. COMMISSIONING After connecting the gas pipe to the stove: 1.1 PURGE THE SUPPLY PIPE to dispel any debris that might block the controls. 1.2 Connect the gas supply to the 8mm compression elbow at the right-hand rear corner of the stove (see Diagram 1).
15 IGNITION FUNCTIONAL CHECK 1 PILOT WILL NOT LIGHT Ensure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark, clean the area. Operate the valve. Is there a spark? Consult Section 2 and retry. Check alignment of pilot burner head, change the ignition lead, see Diagram 1 on page 14.
16 PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE Ensure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark, clean the area. Problem is with the pipe work or fittings which lead to the fire. Correct and retry.
17 2.4 Remove the two screws at the back of the firebox and lift the burner unit clean (see Diagram 3). AR1442 3 3. PILOT UNIT 3.1 Follow the procedure for removing the main burner (see Section 2 ) when the burner is removed from the stove, remove the aeration cover by undoing the two screws (see Diagram 4).
18 3.3 The pilot unit can now be removed by undoing the two screws (see Diagram 6). AR1445 6 3.4 Reassemble in reverse order, do not overtighten. NOTE: SPECIAL CARE SHOULD BE TAKEN WHEN REPLACING THE THERMOCOUPLE TO THE BACK OF THE GAS VALVE TO ENSURE THAT THE SENSOR WIRES FOR THE GAZCO FLUE SURE SYSTEM ARE NOT DISCONNECTED.
19 6.3 Undo the single screw that secures the left hand side of the control cover (see Diagram 10). 10 AR0915 6.4 To release the right hand side of the control cover insert the narrow blade screwdriver into the slot shown in Diagram 11. Lever it gently and pull from the right hand side at the same time.
20 9. GAZCO FLUE SURE SYSTEM 9.1 Open the door and remove the ceramics, placing them carefully to one side. Undo the two screws in the back of the firebox and carefully withdraw the bracket (see Diagram 14). AR1442 14 9.2 Disconnect the two sender wires.
21 11. CHANGING BETWEEN GAS TYPES In order to change between gas types it will be necessary to change the following items: - Pilot Unit - Control Valve** - Main Injector - Aeration Plate - Data Badge The relevant parts can be ordered from Gazco. Always quote the appliance type and serial number when ordering spare parts.
22 SERVICE RECORDS 1ST SERVICE 2ND SERVICE Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of Service: ................................. Next Service due: ............................... N e x t S e r v i c e d u e : .
A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474500 Fax: (01392) 219932 E-mail: yeoman@stovax.
Ein wichtiger Punkt beim Kauf des Geräts Yeoman PR1145 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Yeoman PR1145 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Yeoman PR1145 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Yeoman PR1145 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Yeoman PR1145 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Yeoman PR1145 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Yeoman PR1145 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Yeoman PR1145. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Yeoman PR1145 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.