Benutzeranleitung / Produktwartung Ventilation Hood des Produzenten Wolf
Zur Seite of 16
I NST ALLA TION I NSTR UCTIONS C OOKT OP V ENTILA TION H OODS.
As you follow these instructions, you will notice W ARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip- ment. There are two types of potential hazards that may occur during installation.
3 INST ALLA TION REQUIREMENTS IMPORT ANT NOTE: This installation must be completed by a qualified installer or W olf a uthorized service center technician. I nstaller: P lease read the entire Installation Instructions prior to installation. Save these instructions for the local inspector’ s refer- e nce, then leave them with the homeowner .
O VERALL DIMENSIONS MODEL CTWH30 Overall Width 30" (762) O verall Height (excluding chimney) 6 7 / 8 " (175) O verall Height (including chimney) 3 0 1 / 2 " (775) Max Height (full extension) 48 1 / 2 " (1232) Overall Depth 21" (533) Shipping W eight (shell only) 85 lbs (39 kg) Dimensions may vary to + – 1 / 8 " (3).
HOOD PLA CEMENT W olf cooktop wall and island hoods come with a telescopic chimney flue that allows you to r each a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available.
W ALL HOOD INST ALLA TION INST ALL DUCTWORK IMPORT ANT NOTE: Consult a qualified HV AC Engineer for specific ducting applications. Decide where the ductwork will run between the hood and the outside. A straight, short duct run will allow the hood to perform more efficiently .
7 INST ALLA TION INSTRUCTIONS W ALL HOOD INST ALLA TION ELECTRICAL REQUIREMENTS W olf cooktop wall hoods require a separate, grounded 110 / 120 V AC, 60 Hz power supply .
CONNECT DUCTW ORK U se the screws and wall anchors provided to secure the upper brackets to the ceiling. Position the upper brackets based on the d imension of the telescopic chimney flue. Use an 8" (203) round metal duct to connect the duct collar on the hood to the ductwork above.
9 Dimensions in parentheses are in millimeters unless otherwise specified. INST ALLA TION INSTRUCTIONS ISLAND HOOD INST ALLA TION INST ALL DUCTWORK IMPORT ANT NOTE: Consult a qualified HV AC Engineer for specific ducting applications. Decide where the ductwork will run between the hood and the outside.
10 W OLF COOKT OP VENTILA TION HOODS Secure the upper half of the support frame to the joists and cross framing with four screws p rovided with your hood. Make sure that the screws are driven into the center of the joists and framing for maximum strength.
11 Dimensions in parentheses are in millimeters unless otherwise specified. INST ALLA TION INSTRUCTIONS ISLAND HOOD INST ALLA TION MOUNT HOOD T O SUPPOR T FRAME M ount the hood to the support frame by aligning the four weld screws on the hood to the four holes on the support frame.
12 Dimensions in parentheses are in millimeters unless otherwise specified. W OLF COOKT OP VENTILA TION HOODS A CCESSORIES Optional acces- sories are available through your Wolf dealer . T o obtain local dealer information, visit the Locator section of our website, wolfappliance.
13 INST ALLA TION INSTRUCTIONS INTERNAL BLO WERS INTERNAL BLO WER INST ALLA TION I MPORT ANT NOTE: F or mounting and installation of the internal blower , refer to the specific installation instructions provided with e ach blower . 1) Remove the hood filters.
14 W OLF COOKT OP VENTILA TION HOODS IMPORT ANT NOTE: Before turning the power on to the ventilation hood, make sure the b lower is in the OFF position.
15 CONT ACT I NFORMA TION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com TROUBLE SHOO TING IMPORT ANT NOTE: If the cooktop ventilation hood does not operate properly , follow these t roubleshooting steps: V erify that power is being supplied to the ventilation hood.
807574 9 / 2005 WOLF APPLIANCE COMP ANY , LLC P . O . BOX 44848 MADISON, WI 53744 800-332-9513 WOLF APPLIANCE.COM.
Ein wichtiger Punkt beim Kauf des Geräts Wolf Ventilation Hood (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Wolf Ventilation Hood noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Wolf Ventilation Hood - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Wolf Ventilation Hood reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Wolf Ventilation Hood erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Wolf Ventilation Hood besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Wolf Ventilation Hood verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Wolf Ventilation Hood. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Wolf Ventilation Hood gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.