Benutzeranleitung / Produktwartung SPER2 ML-52919 des Produzenten Vulcan-Hart
Zur Seite of 12
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 INST ALLA TION & OPERA TION MANUAL SPER1 & SPER2 ELECTRIC FR YERS MODEL SPER1 ML-52918 SPER2 ML-52919 SPER0 Frymate ML-52920 FORM 30729 Rev.
— 2 — Installation, Operation and Care of MODEL SPER1 & SPER2 ELECTRIC FR YERS PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE GENERAL Your Vulcan fryer is produced with quality workmanship and material. Proper installation, usage and maintenance of your fryer will result in many years of satisfactory performance.
— 3 — INSTALLATION CODES AND STANDARDS Your Vulcan fryer must be installed in accordance with: 1. State and local codes. 2. The National Electrical Code, ANSI/NFPA No. 70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
— 4 — PL-40545-1 Power On Light High Limit Lights Temperature Controller Power Switch Trouble Light Fry / Melt Switch Heating Light OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS.
— 5 — POWER SWITCH — Controls electric supply to fryer (Optional - hood ventilator to interlock.) POWER ON LIGHT — Indicates when electric supply is on. TEMPERATURE CONTROLLER — Maintains frying temperature by controlling power supply. HEATING LIGHT — When on, indicates temperature control is calling for power to the elements.
— 6 — Split Vat 1. Remove crumb screens. 2. Divide a 50-pound block of shortening into two equal halves (approximately 25 pounds each). 3. Place each half of the shortening directly on the heating elements in each well of the fry tank and slide back.
— 7 — PL-40547-1 Drain Valves Drain Nipple 1. Allow shortening to cool before draining or filling. 2. Consult the operating instructions supplied by the manufacturer of your filtering system before filtering the shortening. 3. Firmly screw the fryer drain nipple (supplied) into the fryer drain valve (Fig.
— 8 — SHORTENING MAINTENANCE Shortening life may be extended by following these important procedures. Do not salt foods over the fryer. Use good quality shortening. Filter shortening daily at a minimum. Keep equipment and surroundings clean. Set thermostats correctly.
— 9 — PL-40546-1 Reset Button 7. Turn power switch OFF at termination of burn-off cycle. 8. Heating elements will heat up in excess of 600 ° F glowing red. If any do not glow, call a Vulcan- authorized service agency. Some smoking, crackling sound and puffs of flame will occur.
— 10 — 6. Drain solution and discard. Close drain valve and fill tank half full with water. 7. Scrub entire inside of tank with a stiff bristle nylon brush. 8. Drain solution and rinse tank thoroughly with clean water. 9. Close drain valve and refill tank with clean hot (minimum 140 ° F) water.
— 11 — MAINTENANCE WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE PERFORMING ANY MAINTENANCE. CALIBRATION PROCEDURES 1. Monitor shortening temperature 1" below the surface with an accurate temperature measuring device.
— 12 — FORM 30729 Rev. A (1-95) PRINTED IN US.A..
Ein wichtiger Punkt beim Kauf des Geräts Vulcan-Hart SPER2 ML-52919 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vulcan-Hart SPER2 ML-52919 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vulcan-Hart SPER2 ML-52919 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vulcan-Hart SPER2 ML-52919 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vulcan-Hart SPER2 ML-52919 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vulcan-Hart SPER2 ML-52919 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vulcan-Hart SPER2 ML-52919 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vulcan-Hart SPER2 ML-52919. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vulcan-Hart SPER2 ML-52919 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.