A product of VULCAN-HART LOUISVILLE, KY 40201-0696 F25125 (Marc h 2003) - NOTICE - This Manual is prepared for the use o f trained Vu lcan Serv ice Te ch ni ci ans and should not be us ed by those not properly qua li fied.
GR SERIES GAS F RYERS F25125 (Marc h 2003) Page 2 of 24 TABLE OF CONTENTS G E N E R A L ................................................................................ 3 Introduction ...................................................................
GR SERIES GAS F RYERS - GENERAL F25125 (March 2003) Page 3 of 24 GENERAL INTRODUCTIO N This Service Manual cover s spec ific s ervice inf orm ation related to the m odels lis ted on the front c over. SINGLE FLOOR M ODEL OR BA TTERY FRYERS Fryers with the Filter-Ready option installed, use the Mobile Filter.
GR SERIES GAS F RYERS - GENERAL F25125 (Marc h 2003) Page 4 of 24 KLEENSCREEN FILTERING SYSTEM The new Kleensc reen filtering s ystem has been integrated into the GR Series fryer battery . The f ilter is housed in a pull-out dr awer assem bly at the base of the f ryer.
GR SERIES GAS FR YERS - REMOVAL AND REPLACEMENT OF PARTS F25125 (March 2003) Page 5 of 24 SPECIFICA TIONS Electrical • 120VAC supply for Filter-Ready fryers and Kleenscreen f ilter m odels only. The f ilter pum p motor draws approxim ately 5 amps. Gas Pressures Manifold (per fryer section) : • Natural - 4" W .
GR SERIES GAS FR YERS - REMOVAL AND REPLACEMENT OF PARTS F25125 (Marc h 2003) Page 6 of 24 NON FILTER REA DY SHOWN 2. W hen replacing door , install sc rews and tighten top and bottom s crews enough to hold door in place. 3. Close door, chec k alignm ent and adj ust if necessar y .
GR SERIES GAS FR YERS - REMOVAL AND REPLACEMENT OF PARTS F25125 (March 2003) Page 7 of 24 5. Remo ve the capillary tube retaining and packing nuts, fr om the bottom of fry tank. 6. Rem ove scr ews securing c apillary tube mounting c lips to the f ry tank heat tube then rem ove capillary tube.
GR SERIES GAS FR YERS - REMOVAL AND REPLACEMENT OF PARTS F25125 (Marc h 2003) Page 8 of 24 NON FILTER REA DY SHOWN 4. Reverse proc edure to install. MAIN BURNER ORIFICE WA RNING: DISCONNECT T HE ELECTRICAL PO W ER TO THE MACHINE AND FOLLOW LOCKOUT / TAGO UT PRO CEDURES.
GR SERIES GAS FR YERS - REMOVAL AND REPLACEMENT OF PARTS F25125 (March 2003) Page 9 of 24 6. Reverse proc edure to install and c heck for proper operation. PILOT BURNER WA RNING: DISCONNECT T HE ELECTRICAL PO W ER TO THE MACHINE AND FOLLOW LOCKOUT / TAGO UT PRO CEDURES.
GR SERIES GAS FR YERS - REMOVAL AND REPLACEMENT OF PARTS F25125 (Marc h 2003) Page 10 of 24 3. Reverse proc edure to install and c heck for proper operation. FRY TA NK ASSEMBLY WA RNING: DISCONNECT T HE ELECTRICAL PO W ER TO THE MACHINE AND FOLLOW LOCKOUT / TAGO UT PRO CEDURES.
GR SERIES GAS FR YERS - REMOVAL AND REPLACEMENT OF PARTS F25125 (March 2003) Page 11 of 24 21. Reverse procedure to install all the parts removed from original fry tank onto replacement fry tank, then inst all the assembly.
GR SERIES GAS FR YERS - SERVICE PROCEDURES AND ADJUST MENTS F25125 (Marc h 2003) Page 12 of 24 SERVICE PROCEDURES AND ADJUSTMENTS WA RNING: CERTAIN PROCED URES IN T HIS SECTION REQUIRE EL ECTRIC AL TEST OR MEASUREMENTS W HILE POW ER IS APPLIED T O THE MACHINE.
GR SERIES GAS FR YERS - SERVICE PROCEDURES AND ADJUST MENTS F25125 (March 2003) Page 13 of 24 NON FILTER REA DY SHOWN GA S M A NIFOLD PRESSURE AD J U S T M E N T WA RNING: SHUT OFF THE GAS SUPPLY BEFORE SERVICING THE UNIT.
GR SERIES GAS FR YERS - SERVICE PROCEDURES AND ADJUST MENTS F25125 (Marc h 2003) Page 14 of 24 NON FILTER REA DY SHOWN A. I f adjustment is necessary, continue wit h procedure. 4. Remove the adjustment screw cap from the gas combination valve. A. To increase pilot flame, turn the screw counterclockwise .
GR SERIES GAS FR YERS - ELECTRICAL OPERAT ION F25125 (March 2003) Page 15 of 24 ELECTRICAL OPERATION COMP ONENT FUNCTION FRYER CONTROLS C o n t r o l T h e r m o s t a t ........... Regulates shortening temperature at t he selected set point. Temperature range from off to 200 / F thru 400 / F.
GR SERIES GAS FR YERS - ELECTRICAL OPERAT ION F25125 (Marc h 2003) Page 16 of 24 GR35 NON FIL TER READY SHOW N GR45 FILTER READY SHOWN 2GR45F KLEENSCREEN FRYER BATTERY SHOWN COMP ONENT LOCA TI ON.
GR SERIES GAS FR YERS - ELECTRICAL OPERAT ION F25125 (March 2003) Page 17 of 24 SEQUENCE OF OPERA TION Millivolt Contr ols Refer to schematic diagram 7825. 1. Conditions. A. G as shutoff valve(s) on and gas combination valve k nob/extension arm in the on position.
GR SERIES GAS FR YERS - ELECTRICAL OPERAT ION F25125 (Marc h 2003) Page 18 of 24 SCHEMATIC DIA GRA M Milliv olt Controls.
GR SERIES GAS FR YERS - ELECTRICAL OPERAT ION F25125 (March 2003) Page 19 of 24 WIRING DI A GRA M S Millivolt Contr ols.
GR SERIES GAS FR YERS - ELECTRICAL OPERAT ION F25125 (Marc h 2003) Page 20 of 24 Junctio n Box, Kl eenscreen Fil tering System.
GR SERIES GAS FR YERS - ELECTRICAL OPERAT ION F25125 (March 2003) Page 21 of 24 Frymate (Dump Sta tion).
GR SERIES GAS FR YERS - TROUBLESHO OT ING F25125 (Marc h 2003) Page 22 of 24 TROUBLESHOOTING A LL M ODELS SYMPTOMS POSSIBLE CA USES Pilot burner will not light. 1. Gas s upply off . 2. High limit ther m ostat open or m alf unction. 3. I ncorrect gas type.
GR SERIES GAS FR YERS - TROUBLESHO OT ING F25125 (March 2003) Page 23 of 24 FRYMATE (DUMP STA TION) WITH OPTIONAL HEA TER SYMPTOM POSSIBLE CA USES No heat. 1. Unplugged. 2. Power switch off or inoperative. 3. Main circuit break er of f or open. 4. Malfunctioning heat as sem bly.
GR SERIES GAS FR YERS - CONDENSED SPARE PARTS LIST F25125 (Marc h 2003) Printed in U.S.A. CONDENSED SPARE PARTS LIST KLEENSCREEN FILTER PART NUMBER DESCRIPTION NOTES 411496-B4 Lighted Rocker Switch, F.
Ein wichtiger Punkt beim Kauf des Geräts Vulcan-Hart GR45 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vulcan-Hart GR45 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vulcan-Hart GR45 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vulcan-Hart GR45 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vulcan-Hart GR45 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vulcan-Hart GR45 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vulcan-Hart GR45 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vulcan-Hart GR45. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vulcan-Hart GR45 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.