Benutzeranleitung / Produktwartung 4GR45MF ML-136423 des Produzenten Vulcan-Hart
Zur Seite of 24
INSTALLATION & OPERATIONAL MANUAL GRM SERIES GAS FRYERS MODELS: 1GR35M ML-136407 1GR45M ML-136408 1GR65M ML-136409 1GR85M ML-136410 1GR45MF ML-136785 1GR65MF ML-136786 1GR85MF ML-136787 2GR45MF ML.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY……………………………… ……….
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -5- Check that the followi ng have been included: Crumb Rack Basket Hanger Twin Fry Baskets (2) Tank Brush Adjustable Casters (4) two locking, two non- locking for freestanding fryers.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -6- Minimum clearance from noncombustible construction: 0” from the sides of the fryer 0” from the back of the fryer Between the fryer and any open-top flame units: 16” (41 cm) Allow space for servicing and operation.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -7- ASSEMBLY The fryer must be restrained to prevent tipping and the splashing of ho t liquid. The means of restraint may be the manner of installa tion, such as connection to a battery of appliances, installing the fryer in an alcove, or by separate m eans such as adequate ties.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -8- Prior to lighting, check all joints in the g as supply line for lea ks. Use soap and water solution. Do not use an open flame. After piping has been checked for leaks, fully purge gas pipes to remove air.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -9- The fryer must be installed with a connec tor (not supplied by Vulcan) complying with the above codes. The fryer must be installed with restrain ing means to guard against transmission of strain to the connector.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -10- BEFORE FIRST USE Cleaning New units are wiped down at the fa ctory to remove an y visible signs of dirt, oil, grease, etc.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -11- LIGHTING THE PILOT A B A Thermostat Knob B G a s C o n t r o l H a n d l e 1. Open the door. 2. Turn the thermostat to OFF (see figure below, view A). The thermostat is located behind the door.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -12- TURNING ON THE FRYER Set the temperature knob to desired temperature. After the set temperature has been reached, the thermostat shuts off the gas flow to burners. The pilot remains lit.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -13- When frying doughnuts and fritters, turn product only once during frying. When cooking French fries or onion rings, shake the basket several times. Batter-covered foods should be dropped carefully, one by one, into shortening or basket.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -14- 5. Slowly open the drain valve to allow oil to fl ow from the fry tank to the filter pan. Then open the drain valve all the way. 6. When fry tank is empty use the tank brush to remove any additional debris.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -15- Use a damp cloth with warm water and a mild soap or detergent. Do not use chlorine or sulfate/sulfide cleaners.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -16- KleenScreen PLUS ® Filtration System Installation and Operational Manual For GRMF Models 2GR45MF Shown GAS KleenScreen PLUS® Mo.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -17- Filtering Instructions for KleenScreen PLUS ® Fryers General The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective tank(s). Only one tank can be dr ained and filtered at a time.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -18- Fully assembled filter screen assembly: F i g . 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -19- INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS ® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RA TE WE RECOMME ND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -20- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -21- 4. Drain the oil out of t he fry tank by turning t he red handle drain valve. The filter pan will begin to fill with oil. When the oil level fills half of the filter pan, pull the red handled filter lever towards you.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -22- FLUSH AND DISCARD: 1. Follow filtering instructions 1- 3, however do not put oil treatment media into the fryer. Drain the fryer oil into the filter pan. 2. Attach the quick disconnect hose to the discard male quick di sconnect fitting.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -23- THERMAL OVERLOAD PROTECTION BUTTON: The motor/pump supplied wi th the filtering system has a thermal overload protec tion circuit that senses when excess heat occurs due to filtering for long periods of time or under heavy load prior to discarding debris buildup.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. K (February 2011) -24- Troubleshooting Chart: Problem: Probable Cause: No Heat: Thermostat dial not turned on.
Ein wichtiger Punkt beim Kauf des Geräts Vulcan-Hart 4GR45MF ML-136423 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vulcan-Hart 4GR45MF ML-136423 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vulcan-Hart 4GR45MF ML-136423 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vulcan-Hart 4GR45MF ML-136423 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vulcan-Hart 4GR45MF ML-136423 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vulcan-Hart 4GR45MF ML-136423 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vulcan-Hart 4GR45MF ML-136423 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vulcan-Hart 4GR45MF ML-136423. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vulcan-Hart 4GR45MF ML-136423 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.