Benutzeranleitung / Produktwartung K-825 des Produzenten Viking
Zur Seite of 14
SECTION TSM 845 P AGE 1 Of 14 ISSUE f VIKING PUMP , INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA VIKING PUMP , INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA TECHNICAL SER VICE MANUAL INTRODUCTION Introduction .
SECTION TSM 845 ISSUE F P AGE 2 OF 14 DO NOT OPERA TE PUMP IF: – The front cover is not installed correctly . – Any guards are missing or incorrectly installed.
SECTION TSM 845 ISSUE F P AGE 3 OF 14 Series 823, 825 and 827 pumps are designed for long, trouble-free service life under a wide variety of application conditions with a minimum of maintenance. The points listed below will help provide long service life.
SECTION TSM 845 ISSUE F P AGE 4 OF 14 CLEANING PUMP: Keep pump as clean as possible. This will facilitate inspection, adjustment and repair work. STORAGE: If pump and coupling are to be stored, drain pump and pour non-detergent SAE 30 weight oil into the pump port.
SECTION TSM 845 ISSUE F P AGE 5 OF 14 4. Remove head from pump. Do not allow idler to fall from idler pin. T ilt top of head back when removing to prevent this. Avoid damaging head gasket set, all gaskets are required to maintain end clearance. 5. Remove idler and bushing assembly .
SECTION TSM 845 ISSUE F P AGE 6 OF 14 ITEM NAME OF P ART ITEM NAME OF P ART ITEM NAME OF P ART 1 Capscrews 5 Ball Bearing (2 Req’d) 9 Bracket 2 External Snap Ring 6 Internal Snap Ring 10 Canister 3 Bearing Housing 7 Key 11 Inner Magnet Assembly 4 Bearing Spacer 8 Outer Mag Assembly 12 Hand Knobs FIGURE 6 MD-C SERIES COUPLING 1.
SECTION TSM 845 ISSUE F P AGE 7 OF 14 4. Insert a brass bar through a port between two rotor teeth and loosen the capscrew holding the inner magnet to the shaft (See Figure 1 1). Do not forget, this is a very strong magnet. If pump disassembly is required, remove the external retaining ring.
SECTION TSM 845 ISSUE F P AGE 8 OF 14 DISASSEMBL Y & ASSEMBL Y OF MD-C SERIES BEARING HOUSING DISASSEMBL Y The bearing housing features two sealed ball bearings along with an outer magnet assembly . If further disassembly of this unit is required, proceed as follows: 1.
SECTION TSM 845 ISSUE F P AGE 9 OF 14 Use a suitable lubricant compatible with the fluid being handled when reassembling the pump. Inspect all parts, especially drilled holes in casing for the suck back system to make sure they are not plugged. Replace any worn parts and polish any burrs; clean all parts; assemble pump.
SECTION TSM 845 ISSUE F P AGE 10 OF 14 INST ALLA TION OF BUSHINGS CARBON GRAPHITE: SILICON CARBIDE ASSEMBL Y COUPLING: SERIES MD-C80 COUPLING When installing carbon graphite bushings, extreme care must be taken to prevent breaking. Carbon graphite is a brittle material and easily cracked.
SECTION TSM 845 ISSUE F P AGE 11 OF 14 ADJUSTING HEAD GASKET END CLEARANCE PUMP ROT A TION Use either of the following procedures to properly adjust the end clearance when replacing gaskets: PROCEDURE A: With balance plate in position, slide rotor and shaft into casing.
SECTION TSM 845 ISSUE F P AGE 12 OF 14 V AL VE - AS, AK AND AL SIZES V AL VE - LIST OF P ARTS 1. V alve Cap 6. V alve Body 2. Adjusting Screw 7. V alve Spring 3. Lock Nut 8. Poppet 4. Spring Guide 9. Cap Gasket 5. Bonnet 10. Bonnet Gasket DANGER ! Before opening any Viking pump liquid chamber (pumping chamber , reservoir , etc.
SECTION TSM 845 ISSUE F P AGE 13 OF 14 Some of the following may help pinpoint the problem: Pump does not pump: ► Lost its prime from air lead or low level in tank. ► Suction lift too high. ► Rotating in wrong direction. ► Strainer clogged. ► Bypass valve open, pressure relief valve set too low or pressure relief valve poppet stuck open.
SECTION TSM 845 P AGE 14 OF 14 ISSUE F VIKING PUMP , INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA © 3/2013 Viking Pump Inc. All rights reserved W ARRANTY Viking warrants all prod.
Ein wichtiger Punkt beim Kauf des Geräts Viking K-825 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Viking K-825 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Viking K-825 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Viking K-825 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Viking K-825 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Viking K-825 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Viking K-825 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Viking K-825. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Viking K-825 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.