✓ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ✓ WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
2 Dear Customer , Thank you for having pur chased and given your pr efer ence to our pr oduct. The safety pr ecautions and r ecommendations r eported below are for your own safety and that of others. They will also pr ovide a means by which to make full use of the featur es offer ed by your appliance.
3 IMPORT ANT PRECAUTIONS AND RECOMMENDA TIONS ✓ After having unpacked the appliance, check to ensure that it is not damaged. If you have any doubts, do not use it and consult your supplier or a professionally qualified technician. ✓ Packing elements (i.
4 COOKING POINTS 1. Auxiliary burner (AUX) - 3.500 BTU/hr 2. Semirapid burner (SR) - 6.000 BTU/hr 3. T riple ring bur ner (TC) - 11.500 BTU/hr CONTROL P ANEL DESCRIPTION 4. Auxiliary burner (AUX) control knob (1) 5. Right semirapid burner (SR) control knob (2) 6.
5 CHOICE OF BURNER (fig. 2.3) The symbols printed on the panel beside the gas knobs indicate the correspondence between the knob and the burner . The most suitable burner is to be chosen according to the diameter and volume capac- ity of the container to be warmed.
6 Do not use steam jet cleaners because the humidity could infiltrate into the appliance making it dangerous. GENERAL RECOMANDA TION ✓ Before you begin cleaning you must ensur e that the hob is switched off. It is advisable to clean when the appliance is cold.
7 CORRECT REPLACEMENT OF THE BURNERS It is very important to check that the burner flame spreader “ F ” and the cap “ C ” have been correctly positioned (see figs. 3.1 and 3.2 ). Failure to do so can cause serious problems. In appliances with electric ignition, check that the electrode “ S ” (fig.
8 W ARNING! THIS APPLIANCE HAS TO BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or pr operty damage. Consult a qualified installer , service agent, or the gas supplier .
9 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code , ANSI Z223.1-Latest Edition.
10 installation to the cabinet min 22” 7/16 (570 mm) 30” (762 mm) 18” (457 mm) min 4” (102 mm) from cut-out max 13” (330 mm) 30” (762 mm) min 20” (508 mm) from cut-out max 13” (330 m m) 18” (457 mm) min 22” 7/16 (570 mm) Fig. 4.
11 20 mm min. 40 mm max. B C A Fig. 4.3 Fig. 4.4 F ASTENING THE COOKTOP (fig. 4.3 - 4.4) ✓ Each cooker top is provided with an installation kit including brackets and screws for fastening the top to fixtur e panels from 2 to 4 cm thick.
Gas supply line Shutoff valve “open” position To cooktop Fig. 5.1 12 All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to te action of LP/Pr opane gas.
13 PRESSURE REGULA TOR INST ALLA TION To cooktop UNLOCK LOCK LOCK To cooktop LOCK Arrow STEP 1 The elbow connection can be turned in the direction requir ed after the manifold female pipe fitting has been slackened by using a wrench.
14 To mains connection To cooktop Manifold test point pressure 1/8” NPT 1/2” G cylindrical (ISO 228-1) male Cooktop manifold Manifold female pipe fitting Elbow connection Connector Pressure re.
15 b) Any conversion requir ed must be performed by your dealer or a qualified licensed plumber or gas service company . Please pr ovide the service person with this manual before work is started on the cooktop. (Gas conversions ar e the r esponsibility of the dealer or end user .
16 1 2 NATURAL GAS REGULATION LP/PROPANE REGULATION A SETTING THE PRESSURE REGULA TOR (fig. 5.5) 1. Unscrew the r egulator cover; 2. Unscrew the A component, r everse and screw it according to the LP/PROP ANE r egulation. CONVERSION TO LP/PROP ANE GAS Every cooktop is provided with a set of injectors for the various types of gas.
17 REGULA TING THE BURNER MINIMUM SETTING When switching from one type of gas to another , the minimum flow rate must also be correct: the flame should not go out even when passing suddenly fr om maximum to minimum flame. The adjustment is performed with the burner lit, as follows: –T urn the knob to the minimum position.
18 If codes permit and a separate ground wir e is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sur e whether the cooktop is prop- erly grounded. Do Not ground to a gas pipe.
19 Wiring diagram key A Ignition coil PA Ignition switches group M Te r m inal block CA Igniter Fig. 6.2 A NL PA M CA CA CA CA WIRING DIAGRAM .
Cod. 1103614-ß1 The manufacturer cannot be held r esponsible for possible inaccuracies due to printing or transcription errors in the present booklet.
Ein wichtiger Punkt beim Kauf des Geräts Verona VEGCT424F (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Verona VEGCT424F noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Verona VEGCT424F - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Verona VEGCT424F reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Verona VEGCT424F erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Verona VEGCT424F besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Verona VEGCT424F verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Verona VEGCT424F. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Verona VEGCT424F gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.