INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER 10000834 11/01 Rev. 2 DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance.
- 2 - T ABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Majestic fireplace IMPORTANT: Read all instructions and warnings carefully before starting installation.
- 3 - This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CAN / CGA-B149 (. 1 or .2) Installation codes for Gas Burning Fireplaces and Equipment. FOR U.S.A Installations follow local codes and/or the current National Fuel Gas Code.
- 4 - A C B D E F K G H I J A B C D E F G H J I K A B C N K D M J I H L FIREPLACE DIMENSIONS MODEL RFS22 MODEL RFS32 A 25" 635mm B 24 1/8" 613mm C 16" 406mm D 20" 508mm E 19" .
- 5 - GAS INLET & MANIFOLD PRESSURES Input Minimum Input Maximum Manifold Pressure NATURAL LP (Propane) 11" wc 13" wc 10" wc 4.5" wc 7" wc 3.
- 6 - INSTALLATION OF REMOTE SWITCH FOR RN/RP GAS VALVE Install on/off switch assembly on either the rear right or left side of the RFS22/RFS32/RFS42 Gas Fireplace. 1. Remove the screw at the back of the cabinet top either on the left or the right side of the fireplace.
- 7 - Fig. 10 STRAIGHT B VENT CHIMNEY COMMON FLUE INSTALLATIONS In some areas it is possible to vent more than one gas fireplace into the same flue. You must ensure that the flue being shared has the proper capacity to handle both fireplaces. Check installation codes for venting capacity information.
- 8 - Check Draft Here Fig. 12 Retrofitting To An Existing Brick Chimney The CFM Majestic Products Company strongly recommends installing an approved chimney liner in an existing brick chimney. This will maximize the potential draft of the chimney and lessen the effects of slow chimney start up.
- 9 - GENERAL GLASS INFORMATION Only glass approved for use in The CFM Majestic Products Company products may be used for replacement. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass.
- 10 - KR2 KR5 KR6 KR4 KR3 KR1 Burner Lava Rock Placement Fig. 16 GLASS CLEANING It will be necessary to clean the glass periodically. During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface.
- 11 - CLEANING PROCEDURE 1. Turn off pilot light at gas valve. 2. Remove front glass. 3. Remove logs. CAUTION: LOGS MAY BE HOT 4. Vacuum burner compartment especially around orifice/ primary air openings. 5. Reinstall logs. 6. Check pilot and main burner operation.
- 12 - 4 . Push in gas control knob slightly and turn clockwise t o "OFF". Do not force. 5 . Close control access panel. 1 0 . Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears.
- 13 - SIT 630 GAS V AL VE Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1.
- 14 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT NOV A 820 MILLIVOL T V AL VE Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT.
- 15 - • GAS SUPPLY ON • SUPPLY LINE HOOKED UP • SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. • FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO — 1/8" GAP TO PILOT HOOD NEEDED. • ALL WIRING CONNECTIONS • REPLACE PIEZO IGNITOR • FOR AIR IN THE LINES • THERMOPILE NEEDS A MINIMUM 325mV.
- 16 - REPLACEMENT P ARTS LIST D ESCRIPTION RFS22 RFS32 RFS42 (1) Top or Bottom With Magnets 1. Log Set Complete 10000160 10000160 10000205 1a. Log Ember Front KR1 KR1 SR1 1b. Log Front Left KR2 KR2 SR2 1c. Log Front Right KR3 KR3 SR3 1d. Log Rear KR4 KR4 SR4 1e.
- 17 - REPLACEMENT P AR TS 29 30 27 5/6a/b 19 18 13 11 17 15 28 7a/b 21a,b 44 41 42 43 31 32 36 a/b 37 39 46 45 39 43 41 42 it HI LO OFF PILOT 25a/b 48 47 40 14 33 38 42 39 34 35 39 43 33 49 26 #1 - C.
- 18 - MRC1 - On/Off Button Remote Control MRC2 - Temperature Control Remote MRC3 - Temperature Control w/digital display & 24 hour programmable clock I M T - Wall Mounted Thermostat REMOTE CONTRO.
Ein wichtiger Punkt beim Kauf des Geräts Vermont Casting RFS22 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vermont Casting RFS22 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vermont Casting RFS22 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vermont Casting RFS22 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vermont Casting RFS22 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vermont Casting RFS22 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vermont Casting RFS22 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vermont Casting RFS22. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vermont Casting RFS22 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.