Benutzeranleitung / Produktwartung R18CFL des Produzenten Vermont Casting
Zur Seite of 14
— Do not store gasoline or other flammable vapors or liquids near this or any other appliance. — WHA T T O DO IF Y OU SMELL GAS • Do not try to light any appliance. • Do not touch an y electrical switch; do not use any phone in y our building.
2 20003889 Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read these directions thoroughly before installation. For assistance or additional infor- mation, consult your gas log dealer , qualified installer , service agency or gas supplier .
20003889 3 The Logsets have been designed and tested to operate safely when installed according to the installation instructions contained in this manual. Read all instructions before starting the installation. • The logset should be inspected before use and at least annually thereafter .
4 20003889 CA UTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance. Are you burning Natural Gas? If you have Propane Gas, you need to purchase a factory authorized safety pilot kit (see below).
20003889 5 This Damper Stop is designed to work on all CFM Specialty Home Products BR, BC, SR, SC, TF and TL series fireplaces. For all other fireplaces, refer to Page 6. When installing a decorative gas appliance in a fireplace, some local codes require this Damper Stop to be used so the Damper will not close completely .
6 20003889 The Damper Stop provided keeps your damper from accidentally closing during operation of your set. This Damper Stop must be installed onto your Damper at all times . NOTE: The damper clamp is designed to hold the damper plate open 3 inches.
20003889 7 Leak T est Pr ocedures Create a mixture of equal parts soap and water . Apply to all the joints of the pipe fittings from the gas supply pipe to the burner . T urn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap solution applied to the joints, there is a leak.
8 20003889 1. Place the Elevated Grate Steps onto the back of the Grate and attach the Fettel to front of Grate as shown in Figure 7. 2. Place the Grate over the Burner Pan so the front legs of the Grate are 1” behind the front edge of the Pan, as shown in Figure 8.
20003889 9 1. T urn the gas shut-of f valve to OFF . 2. W ait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow the safety information above. If you don’t smell gas, go on to the next step. 3. Light a match and lay it on top of the pan material, about 2” from the end of the supply side of the pan.
10 20003889 Tr oub leshooting Log Set is Smoking/Sooting Excessively It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where flame contacts the logs.
20003889 11 8 11 7 5 4 2 3 17 13 18 16 14 19 10 12 15 9 6 1 a b c d e f g h CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. R18 / 24 / 30CFL V ented Gas Logs 1.
12 20003889 R18 / 24 / 30CFL V ented Gas Logs (continued) Ref. Description R18CFL R24CFL R30CFL 11 . Cast Front Grate w/Clips CIGF18 CIGF24 CIGF30 12. Grate 20000924 20000925 20000926 13. Grate Step 20000955 20000955 20000955 14. Pan & Extension Assembly 20003840 20003841 20003842 15.
20003889 13 W ARRANTIES OF MERCHANT ABILITY OR FITNESS FOR A P ARTICULAR PURPOSE), ALL OF WHICH ARE HEREBY EXPRESSL Y INCLUDED. IN NO EVENT SHALL ANY IMPLIED W ARRANTY PRESCRIBED BY LA W (NOTWITHST ANDING THE FOREGOING EX- PRESS EXCLUSION) REMAIN IN EFFECT AFTER EXPIRA TIONS OF THE W ARRANTIES SET FORTH IN P ARAGRAPHS A AND B.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Pr oducts.
Ein wichtiger Punkt beim Kauf des Geräts Vermont Casting R18CFL (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vermont Casting R18CFL noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vermont Casting R18CFL - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vermont Casting R18CFL reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vermont Casting R18CFL erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vermont Casting R18CFL besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vermont Casting R18CFL verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vermont Casting R18CFL. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vermont Casting R18CFL gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.