- 1 - INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER 10002788 06/00 Rev. 0 Builder Rear V ent Dir ect V ent Models DBR33 DBR36 DBR39 DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
- 2 - T ABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
- 3 - IMPORTANT: PLEASE REVIEW THE FOLLOWING CAREFULLY Remove any plastic from trim parts before turning the fireplace ON. It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle.
- 4 - A 36" 914mm B 34 1/4" 870mm C 21" 533mm D 33" 838mm E 24" 610mm F 16" 406mm G 19" 483mm H 23 7/8" 606mm I 27 1/2" 698mm J6 3/4" 171mm K 10".
- 5 - Ref. Mantel Ref. Mantel From Mantel Leg from Depth Top Louvre Fireplace Side V 10" (254 mm) A 12" (305 mm) 10" (254mm) W 8" (203 mm) B 10" (254 mm) 8" (203mm) X 6&q.
- 6 - Do not use this fireplace if any part of it has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control which has been under water.
- 7 - When using copper or flex connector use only approved fittings. Always provide a union so that gas line can be easily disconnected for burner or fan servicing. See Fig. 7. See gas specification for pressure details and ratings. Always check for gas leaks with a mild soap and water solution.
- 8 - GENERAL INFORMA TION ON ASSEMBLING THE VENT PIPES Join pipes and secure joints with three (3) sheetmetal screws. (See Fig. 10) Wipe off excess sealant. CRIMPED END PIPES Before joining elbows and pipes apply a bead of high temperature sealant to crimped end of elbow or pipe.
- 9 - V V V V V V V V V X X X D E B B B C B M B A J K A F L G G TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) H I Fixed Closed Fixed Closed Openable Openable Fixed Closed G G N N A Fig. 12 Your fireplace is approved to be vented either through the side wall, or vertical through the roof.
- 10 - Fig. 13 *IMPORTANT* DIRECT THROUGH SIDEWALL Note: Vent Starter Kit Model 7DVRVT must be used in straight out the wall rear vent applications. Maximum Vent Length .
- 11 - Measure wall thickness and cut adjustable zero clearance sleeve parts to proper length (MAXIMUM 12"/305mm). Adjust sleeve to maximum (10-3/8 x 9-3/8). and attach to firestop with #8 sheet metal screws (supplied). (Fig. 16) Install firestop assembly.
- 12 - The maximum horizontal vent run is 20 feet (6100mm) when the vertical vent rise is 7.5 feet (2286mm). Fig. 19 Fig. 19 VERTICAL SIDEWALL APPLICATIONS Since it is very important that the venting .
- 13 - HORIZONTAL DIMENSION SEE PAGE 15 FOR VENTING REQUIREMENTS FOR SNORKELS. 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 eg: A eg: B VERTICAL DIMENSION FROM THE FLOOR OF THE UNIT TO THE CENTRE OF THE HORIZONTAL VENT PIPE Fig.
- 14 - COMBUSTIBLE WALLS (Fig. 25): Cut a 9-3/8"H x 9-3/8"W (240 mm x 240 mm) hole through the exterior wall and frame as shown (Fig. 24). NON-COMBUSTIBLE WALLS (Fig.
- 15 - STEP 4 (Fig. 28) Measure the horizontal length requirement including a 2" (50mm)overlap, i.e. from the elbow to the outside wall finish plus 2" (or the distance required if installing a second 90 o elbow). Always install horizontal venting on a level plane.
- 16 - DO NOT BACK FILL AROUND SNORKEL. SOIL SHOULD NOT BE LESS THAN 4" (100mm) BELOW SNORKEL. FOUNDATION RECESS SNORKEL SCREWS WALL SCREWS SHEET METAL WATERTIGHT SEAL AROUND PIPE If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel.
- 17 - Fig. 39 Clearance above a roof shall extend a mini- mum of 24" (610mm) above the highest point when it passes through the roof surface, and any other obstruciton within a horizontal distance of 18" (450mm). 1. Locate your fireplace. 2.
- 18 - GLASS FRAME REMOVAL 1. Shut off gas. 2. Let the fireplace cool if it has been operating. 3. Remove top louvre. (See Louvre Removal) 4. Open the lower louvre assembly. 5. Release the two clamps at the bottom of the window frame by pulling down on the clamp handles.
- 19 - 1 . Remove front glass. (See "Glass Removal" Section) 2. Remove logs from the packaging. As with all plastics — these are not toys and should be kept away from children and infants.
- 20 - The burner and control system consists of: • burner tube • gas orifices • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician.
- 21 - TO TURN OFF GAS TO APPLIANCE 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears.
- 22 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT 820 NOV A MILLIVOL T V AL VE START CHECK GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK GAS SUPPLY ON • SHUTOFF VALVE OPEN • CONFIRM GAS HOOK-UP LIGHT PILOT WITH PIEZO IGNITION • ELECTRODE GAP MIN.
- 23 - GAS SUPPLY ON • SUPPLY LINE HOOKED UP • SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. • PIEZO NOT TIGHT ENOUGH FOR GOOD GROUND. • FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO (RED BUTTON) — 1/8" GAP TO PILOT HOOD NEEDED.
- 24 - REPLACEMENT P AR TS LIST - REAR BUILDER SERIES D ESCRIPTION DBR33 DBR36 DBR39 1. Log Set Complete 10000470 10000023 10000024 1a. Log Front Left BA2 BB6 BC5 1b. Log Front Right BA3 `BB7 BC6 1c. Log Rear BA4 BB8 BC7 1d. Log Top Left BA5 BB9 BC8 1e.
- 25 - FOR FIREPLACES EQUIPPED WITH SIT 820 MILLIVOLT GAS VALVE 23 22 20 21 18 6 a/b 15 13 9 8 a/b 12 11 14 a/b 27 28 29 26 26 25 17 19 16 a/b 7 a/b 30 2 3 24 32 31 4a/b 5 10 34 a/b 8 a/b 35 36 37 38 .
- 26 - WIRING INSTRUCTIONS OPTIONAL FAN KIT - FK12 and FK24 FK12 This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK12 Fan Assembly is a fixed speed fan system and does not allow for variable speed control.
- 27 - 6. Hang Bay Window Frame assembly over existing glass frame. Do not remove existing glass frame 7. Re-install top louvre assembly. Remove all plastic from brass trims 8. Open the Bottom Bay Louvre door and screw two (2) self tapping screws (as per step 1 above) to the bottom of the unit where the hinges were.
- 28 - OPTIONAL CERAMIC REFRACTORY INSTALLATION OPTIONAL SCREEN KIT INSTALLATION To install the Frame Window Screen: WARNING: DO NOT install the frame window screen with the fireplace ON 1. Slide the top edge of the frame window screen through the slots beneath the main frame window top trim support.
- 29 - CRIMPED ENDS VENTING COMPONENTS 7DVRVT - Through the wall Rear Vent Termination Starter Kit -Model 7DVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7DVSKV-A order 1/1.
- 30 - TWIST LOCK VENTING COMPONENTS Starter Kit -Model 7TDVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to.
- 31 -.
- 32 - 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885 www .vermontcastings.com CFM Majestic, Inc. © Copyright CFM Majestic, Inc.
Ein wichtiger Punkt beim Kauf des Geräts Vermont Casting DBR39 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vermont Casting DBR39 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vermont Casting DBR39 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vermont Casting DBR39 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vermont Casting DBR39 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vermont Casting DBR39 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vermont Casting DBR39 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vermont Casting DBR39. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vermont Casting DBR39 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.