Save this manual for future reference WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® 1. This appliance is only for use with the type of gas indicated on the rating plate.
3 105273 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Product Identification Flame-Max ® Golden Oak Logs PRODUCT FEA TURES OPERATION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney.
4 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
5 105273 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® AIR FOR COMBUSTION AND VENTILA TION Continued Figure 3 - Ventilation Air from Outdoors Figure 2 - Ventilation Air from Inside Building.
7 105273 OWNER’S MANUAL WARNING: Never install the heater • in a bedroom or bathroom un- less installed as a vented ap- pliance (see page 10) • in a recreational vehicle • where curtains, furn.
8 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening.
9 105273 OWNER’S MANUAL INST ALLA TION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood Figure 7 - Minimum Mantel Clearances When Using Hood Continued MANTEL CLEARANCES In addition to meeting noncombustible ma - terial clearances, you must also meet re- quired clearances between fireplace opening and mantel shelf.
10 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® Area of Various Standard Round Flues Diameter (ins.) Area (sq. ins.) 5" 20 sq. inches 6" 29 sq. inches 7" 39 sq. inches 8" 51 sq. inches INSTALLING HEATER BASE ASSEMBLY WARNING: You must secure this heater to fireplace floor.
11 105273 OWNER’S MANUAL Figure 11 - Attaching Flexible Gas Hose to Heater Figure 12 - Attaching Base Assembly to Fireplace Floor Fitting Flexible Gas Hose (if allowed by local codes) Masonry Screw .
12 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® INST ALLA TION Continued CONNECTING TO GAS SUPPLY NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes. Installation Items Needed Before installing heater, make sure you have the items listed below.
13 105273 OWNER’S MANUAL Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Fig- ure 14). 2. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter . 3 . Check all joints from gas meter to manual shutoff valve (see Figure 15).
14 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place one-piece log set on grate to fit as illustrated in Figure 16.
15 105273 OWNER’S MANUAL LIGHTING INSTRUCTIONS OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
16 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® Ignitor Electrode Pilot Burner Figure 19 - Pilot CAUTION: Do not try to adjust heating levels by using the manual shutoff valve. WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time.
17 105273 OWNER’S MANUAL ON OFF REMOTE O F F P I L O T O N L O I H TEMP ST ATUS HI LO MAN ON AUT O OFF Increases Room Temperature Decreases Room Temperature Turns Burner On and Off Shows Current Operation Mode Shows Temperature Setting Allows Burner to be Turned On and Off with the Hand- Held Remote Unit.
18 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use.
19 105273 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
20 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smok.
21 105273 OWNER’S MANUAL WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
22 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX ® GOLDEN OAK LOG MODELS VYD18NRA, VYD24NRA, VYD30NRA, AND VYD36NR 4 13 13 14 22 13 8 18 7 .
23 105273 OWNER’S MANUAL P ARTS LIST VYD18NRA, VYD24NRA, VYD30NRA, AND VYD36NR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual. KEY PART NUMBER FOR NO.
24 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.
25 105273 OWNER’S MANUAL ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual.
LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Ein wichtiger Punkt beim Kauf des Geräts Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.