Benutzeranleitung / Produktwartung 1537G des Produzenten United States Stove
Zur Seite of 24
1 C O M P A N Y U N I T E D S T A T E S S T O V E C S S U Model 1537G OWNERS MANUAL SOLID FUEL W ARM AIR FURNA CE CAUTION: READ ALL INSTRUCTIONS CARE- FULLY BEFORE STARTING THE INSTALLATION OR OPERATI.
2 NO TE: Y OUR UNIT MUST BE INST ALLED BY A QU ALIFIED FURNA CE INST ALLER. Y ou've purchased one of America's Finest W ood and Coal Burning Furnaces. By heating with wood and coal you're helping CONSER VE AMERICA'S ENERGY! W ood is our Renewable Energy Resource.
3 CAUTION! CLEANOUT OF THE HEA T EXCHANGER, FLUE PIPE, CHIMNEY , AND DRAFT INDUCER (IF USED), IS ESPECIALL Y IMPORT ANT A T THE END OF THE HEA TING SEASON T O MINIMIZE CORROSION DURING THE SUMMER MONTHS, CA USED BY ACCUMULA TED ASH. Y our Fur nace has the follo wing labels .
4 1. Check your local codes. The installation must comply with their rulings. 2. Do not install this furnace in a mobile home or trailer. 3. Always connect this furnace to a chimney and vent to the outside. Never vent to another room or inside a building.
5 Y our CLAYTON Furnace is designed to be a supplemental or central heating source for your home. This Solid Fuel Furnace may be installed in conjunction with a properly operating central furnace that.
6 32-1/8" 1-3/4" 9" 33-7/8" 49-1/8" 24-1/16" 40-11/16" Figure 1B 1400/1500 DIMENSIONS OF FURNACE FIGURE 1 1537G.
7 LOCA TING THE FURNA CE 1. The furnace should be located in the same room as the central system and as close as possible, but not closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace.
8 10' 2' MIN. 3' MIN. 6" CHIMNEY CONNECTOR 6" ELBOW 6" SOLID DAMPER 6" BAROMETRIC DRAFT REGULATOR (OPTIONAL) REFER TO CHIMNEY MANUFACTURER'S INSTRUCTIONS AND PARTS.
9 RULES FOR CONNECT OR PIPE INST ALLA TION 1. The crimped end of the chimney connector fits inside the furnace flue collar. Install additional chim- ney connectors and elbow with the CRIMPED END TOWARD THE FURNACE. This will allow any condensation in the flue to run back into the furnace.
10 ASSEMBL Y OF FURNA CE Your furnace requires the following items to be assembled or installed by the service person: Feed Door Pull Handle Feed Door Locking Handle Blower(s) and Blower Controls Elec.
11 LOAD FAN LINE LOAD LIMIT LINE BREAK OFF JUMPER FOR LOW VOLTAGE FAN "OFF" INDICATOR FAN "ON" INDICATOR LIMIT INDICATOR Honeywell LIMIT SWITCH R1 R2 G B W 110 VAC, 60 HZ.
12 INST ALLA TION Please see all methods of Installation in Appendix at the rear of this booklet. Pipe to combustible: Sides: 21" Back: 18" The installation must be made only on a noncombustible floor.
13 2" MIN. AIR SPACE REQUIRED BY CODE 18" MIN. CENTRAL FURNACE Figure 12 P OWER F AILURE I NSTRUCTIONS : Operation after loss of power-- 1. Remove filter if provided 2. Do not expect to keep home at normal temperatures. 3. Do not load fuel above bottom of feed door.
14 CAUTION GASES THAT ARE DRIVEN FROM FRESH COAL MUST BE BURNED OR THEY WILL ACCUMULATE AND EXPLODE. NEVER SMOTHER A FIRE WHEN ADDING FRESH COAL. CAUTION DO NOT OPERATE WITH THE FEED AND/OR ASH DOOR OPEN. THIS FURNACE IS DE- SIGNED FOR THERMOSTATIC OPERATION.
15 SER VICE HINTS Do not expect a furnace to draw. It is the chimney that creates the draft. Smoke spillage into the house or excessive build-up of water or creosote in the chimney are warnings that the chimney is not functioning properly. Correct the problem before using furnace.
16 MODEL 1537G REPAIR PARTS.
17 KEY PART# DESCRIPTION QTY. 1 68215 FIREBOX WELDMENT 1 2 40246 FLUE CO LLAR 1 3 88032 FLUE CO LLAR GASKET 1 4 23458 CABINET BOTTOM 1 5 40258 BACK LI NE R 1 6 40256 SHAKER FRAME 2 7 40257 SHAKER GRAT.
18 COLD AIR DUCT 6" PIPE DAMPER OPTIONAL 11 RPT 90 ELBOW FURNACE PIPE CONNECTOR Central Installation Fig. 16-1 (U.S. ONLY) Add-On Installation COLD AIR DUCT 6" PIPE DAMPER 90 ELBOW FURNACE PIPE CONNECTOR EXISTING GAS/OIL/ELECTRIC FURNACE 8" PIPE Fig.
19 (U.S. ONLY) COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX APPENDIX INSTALLATION A.
20 INSTALLATION B INSTALLATION C COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX PLENUM COLLECTOR BOX COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX PLENUM ELBOW PLENUM TOP (OPTIONAL) (U.
21 2" MINIMUM CLEARANCE DUCT WORK 11 PCS (OPTIONAL PLENUM FAN CONTROL LOCATION) FURNACE PLENUM EXISTING FURNACE ANTI-BACKDRAFT FLAPPER SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION D 2" MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION E BAFFLE (U.
22 2" MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION F 2" MINIMUM CLEARANCE DUCT WORK SOLID FUEL FURNACE INSTALLATION G COLD AIR .
23 2" MINIMUM CLEARANCE EXISTING OIL, ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE INSTALLATION H EXISTING OIL, ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE (TOP VIEW) (FRONT VIEW).
24 1. Smoking when feed door a) Insufficient Draft. a) Set Thermostat higher. is open. b) Clogged chimney or chimney b) Clean Chimney. connector. c) Add raincap to chimney. c) Down draft in chimney. 2. Furnace does not heat. a) Wood not seasoned and dry.
Ein wichtiger Punkt beim Kauf des Geräts United States Stove 1537G (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie United States Stove 1537G noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für United States Stove 1537G - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von United States Stove 1537G reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über United States Stove 1537G erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon United States Stove 1537G besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von United States Stove 1537G verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit United States Stove 1537G. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei United States Stove 1537G gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.