Benutzeranleitung / Produktwartung 43xx des Produzenten Ultra Start
Zur Seite of 24
Co v er s All 42xx and 43xx Series R emote Star ter/Alar ms -The system must be placed into Service Mode before any service work is started on the vehicle. It is the sole responsibility of the vehicle owner to ensure that this is done. The manufacturer accepts no liability or responsibility for accidental starting of the vehicle.
T able of Contents Page 2 Pre-Insta llation Page 3 Components Feature List Pre-Installation Insta llation Procedures Page 4 Wiring Diagrams Page 5-7 Wire Description Page 8-9 6 Pin Connector Auxiliary.
R ecommended Pre-Installation Procedure s F ea ture List - Control module - 2way LCD and 1way transmitters - Antenna with built in - 6 pin main harness with dual - Program Button and LED’s 30 amp power inputs.
R ecommended Installation Procedures Under Hood Connections - Route the hood pin and tach wire through the firewall into the engine compartment. If possible route the wires through a factory rubber grommet. If drilling a hole through the firewall, BE CAREFUL .
Wiring Diagram - 1 1 pin + 4 pin Connectors BLUE GREEN RED RED YELLOW Starter Output Heater/Acc Output Power Input Ignition Output Selectable Output Power Input 30amp Output 30amp Output 30amp Input 3.
Wiring Diagram 14 pin connector BLUE GREEN RED RED YELLOW 1 5 3 2 4 6 Starter Output Heater/Acc Output Power Input Ignition Output Selectable Output Power Input 30amp Output 30amp Output 30amp Input 3.
W iring Dia gr am auxiliar y connector s Door lock output Door unlock output (-) When Running Low Current (-) Output Low Current (+) Output Door lock module output only* ACTIVE RF ANTENNA** (-) 500ma .
6 Pin P o wer Connector 6-pin Description T est For Wire 1-Y ellow 30amp S t arter Output - This wire will test 0volts in off, accessory and in the ignition position.
Auxiliar y Connectors - continued from previous pag e 1 1-Black Ground - System Chassis Ground Input. 12-Blue Glow Plug - Diesel Glow plug input, detects both 12volt and negative glow plug signals. Programmable input. See Menu 3. 13-Blue/White T ach - A/C T ach Signal Input.
Step 1 - Connect All Of the F ollowing W ires 6 Pin P ow er Connector Y ellow 30amp St arter Output - 12volt s during start position only . Green 3 0amp Heater Output - 12volt s in the accessory position off during start and 12volts during run. Red 30amp Power Input - Constant 12volt power at ignition harness or battery .
Manual T ra nsmission “M” Models Never install an automatic transmission remote starter into a manual transmission vehicle!!! Doing so may result in serious injury or death. Do not install remote starters in convertible vehicles! The following wires must be connected In addition to the basic remote starter installation.
Auto T ac h Learn 1) T urn the ignition key to the “ON” position. (The park light s will turn on*). 2) S tart the vehicle with the key , The LEDs on the antenna will turn on if a proper t ach signal is detected**, then after 30-35 seconds the p ark lights will flash and the siren will chirp twice to confirm T ach Learn.
Impor tant T ac h Notes T ach Learning the remote starter is one of the most import ant steps in the installation process. Do not tach learn vehicle while the engine is in high idle. T o ensure the best possible tach setting, ensure that the vehicle is at low idle/ normal operating RPM.
Entering Pro gra m Mode 1) With the ignition in the OFF position, turn the ignition key from “Of f” to “On” 3 times, ON-OFF-ON-OFF-ON within three seconds. (Leave the key in the ON position) 2) Press and release the Program Button located on the antenna.
Quic k View Progr amming * See the following p ages for more detailed programming instructions. Menu 1 - Press Lock 1 Flash 2 Flashes 3 Flashes 1 Ignition Lock Enabled Lock Only Disabled 2 Siren Chirp T ype 1 T ype 2 All Chirp s 3 Lock&Unlock Options Double Unlock 3 second .
Menu 1- User Settings Ignition ON-OFF-ON-OFF-ON Press & Release Program Button Press Button #1 (Lock) Setting 1 Ignition Auto Lock 1) Ignition Lock & Unlock Enable 1 Flash/Chirp Doors Lock/Unlock with Ignition key . 2) Ignition Lock Only 2 Flashes/Chirps Doors Lock when ignition is turned ON only .
Menu 1- User Settings.. . continued from pr e vious pa ge Setting 6 Sensor Enable/Disable 1) Sensor Disabled 1 Flash/Chirp Imp act Sensor Disabled *2) Sensor Enabled 2 Flashes/Chirps Imp act Sensor Enabled Press & Release the Program Button 6 Times (Setting 6) Confirmed with 6 LED flashes.
Menu 2- Additional Settings ...continued fr om previous page. Menu 3- Star ter Settings Ignition ON-OFF-ON-OFF-ON Press & Release Program Button Press Button #3 (St art) Setting 1 S pecial Door Lock/Unlock Operations (Factory Alarm Rearm) . 1) T ype 1 1 Flash/chirp Unlock pulse before start.
Menu 3- Start er Settings - Continued F r om Prev ious Page Setting 2 With 14pin Connector- Gas/Diesel Mode (Auxiliary Connector Pin 12) 1) (-) Input 1 Flash/chirp (-) Glow Plug input. W aits maximum 30 seconds then start s. 2) T ime Delay 2 Flashes/chirps W aits for approximately 15 seconds then remote st arts.
Menu 4- T ac h Settings Ignition ON-OFF-ON-OFF-ON Press & Release Program Button Press Button #4 Setting 1- Auto T ach Learn 1) Perform a System Reset. See p age 15. 2) T urn the ignition key on. (Park lights will turn on). 3) S tart the vehicle, t he LEDs on the antenna will come on when a proper tach signal is detected*.
T r ansmitter Pr ogr amming Ste p 1 - Within 3 seconds turn the ignition ON-OFF-ON-OFF-ON - Leaving Key ON Ste p 2 - Press and hold the Program Button - The park light s will turn ON and the siren will chirp once.* Continue to hold the Program Button , the park light s will turn off and the siren will chirp 5 times quickly .
87 86 85 87a 30 87 86 85 87a 30 Lock Un lock V ehicle Lock/Unlock Switch T o Control Relay or Actuator Green Fused +12V Blue Ground Neg a tiv e T ype Door Locks 250ma Neg a tiv e Door Loc ks (More T h an 250ma) P ositiv e T ype Door Loc ks Note: When installing relays always use a fused power source.
87 86 85 87a 30 87 86 85 87a 30 Blue Green Lock Un lock V ehicle Lock/Unlock Switch To Actuator Fused +12V x x Cut Cut 87 86 85 87a 30 Ground DIAGN OSTICS 13 87 86 85 87a 30 87 86 85 87a 30 Blue Green.
DIA GNOSTICS If the remote starter does not activate when the st art button is pressed the park light s will flash a diagnostic to indicate what shutdown input has been triggered. For example when the start button is pressed the p ark lights flash 3 times slowly .
Ein wichtiger Punkt beim Kauf des Geräts Ultra Start 43xx (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Ultra Start 43xx noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Ultra Start 43xx - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Ultra Start 43xx reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Ultra Start 43xx erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Ultra Start 43xx besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Ultra Start 43xx verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Ultra Start 43xx. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Ultra Start 43xx gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.