Benutzeranleitung / Produktwartung CLRCO2075 des Produzenten U-Line
Zur Seite of 48
Service and Parts Manual Supplement For Model CLRCO2075 U-Line Cor poration U-Line Cor poration 8900 Nor th 55th Street PO Bo x 245040 Milwauk ee, WI 53223 Milwauk ee, WI 53224-9540 www .
INTRODUCTION 2 Design ■ Features ■ Performance INTRODUCTION Three generations of pride and quality manufacturing and design improvements are built into all U-Line products. The result: U-Line leads the market with innovative technology and superior craftsmanship.
INTRODUCTION 3 Design ■ Features ■ Performance SERIAL NUMBER FORMA T The serial number is divided into four segments. A typical serial number is 035497-03-0004. The first two digits of the first segment, 03, represents the year the unit was made. The next four digits of the first segment, 5497, represents the shop order number .
INTRODUCTION 4 Design ■ Features ■ Performance NOTES.
INTRODUCTION 5 Design ■ Features ■ Performance T ABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Serial Number Format . . . . .
GENERAL INFORMA TION 6 Design ■ Features ■ Performance LIMITED W ARRANTY U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of one ye.
GENERAL INFORMA TION 7 Design ■ Features ■ Performance W ARRANTY CLAIMS PROCEDURE When submitting claims for warranty payment, please follow these guidelines. Y ou can use any form you would normally use to bill your customer (your own computer generated form, Narda, USA, etc.
8 Design ■ Features ■ Performance SAFETY PRECAUTIONS Do not attempt to service or repair the unit until you have read the entire procedure. Safety items through- out this manual are labeled with W arning or Caution.
9 Design ■ Features ■ Performance SER VICING ELECTRICAL SPECIFICA TIONS Compressor Pins To measure start winding resistance, measure across the C-S pins. To measure run winding resistance, measure across the C-R pins. These pins should never measure any resistance to ground.
10 Design ■ Features ■ Performance LEVELING AND INST ALLA TION REQUIREMENTS It is extremely important that the unit is level. If it is not level, the ice mold will not fill evenly . This can cause a reduction in ice rate, uneven sized cubes or water spilling into the storage area which will cause the ice in the bin to melt prematurely .
11 Design ■ Features ■ Performance GRA VITY DRAIN INST ALLA TION These guidelines must be followed when installing drain lines to prevent water from flowing back into the ice maker storage bin and potentially flowing onto the floor causing water damage: • Drain lines and fittings must have a 5/8" inside diameter .
12 Design ■ Features ■ Performance CONNECTING A DRAIN PUMP If a gravity drain connection is not available, U-Line strongly recommends the use of the U-Line P60 drain pump. If your CLRCO2075 is not equipped with a factory installed pump, a P60 drain pump is available through your Dealer , or direct from U-Line.
13 Design ■ Features ■ Performance SER VICING SELF-CLEANING CYCLE INSTRUCTIONS To maintain operational efficiency , clean unit every six months (depending on water conditions more or less frequent cleaning may be necessary).
14 Design ■ Features ■ Performance INTERIOR ST ORAGE BIN CLEANING 1. Disconnect power from the ice maker . 2. Remove any ice from the storage bin. 3. W ipe down the storage bin with a solution of non-abrasive mild soap or detergent and warm water .
15 Design ■ Features ■ Performance 6. When the initial three-minute fill cycle is complete, the unit will enter ice making and refrigeration mode (1) if the bin is empty or below the sensor .
16 Design ■ Features ■ Performance SEQUENCE OF OPERA TION Mode 1: Ice Making and Refrigeration ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REF.
17 Design ■ Features ■ Performance SER VICING Mode 2: Ice Making and No Refrigeration ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR.
18 Design ■ Features ■ Performance SER VICING Mode 3: Refrigeration and No Ice Making ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR.
19 Design ■ Features ■ Performance SER VICING Mode 4: Ice Harvest (No Refrigeration Possible) ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFR.
20 Design ■ Features ■ Performance Mode 5: All Satisfied ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR EVAPORATOR CAPILLARY TUBE HO.
21 Design ■ Features ■ Performance Mode 6: Water Fill - No Refrigeration Required ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR EVA.
Design ■ Features ■ Performance Mode 7: Cleaning (No Refrigerator Possible) ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPASS VALVE (UPPER) VALVE (LOWER) REFRIGERATION REFRIGERATOR EVAPORATO.
23 Design ■ Features ■ Performance SER VICING Mode 8: Water Fill with Refrigeration Required (Note: Normal Start-up with a warm refrigerator) ICE MAKER EVAPORATOR COMP - COMPRESSOR CONDENSER BYPAS.
24 Design ■ Features ■ Performance THERMIST ORS Condenser Thermistor The condenser thermistor senses the refrigeration system “high side” temperature. This is used in conjunc- tion with the control board to determine the length of the freeze and harvest cycles.
25 Design ■ Features ■ Performance CONTROLLER The temperature controller is located below the clear ice maker . It consists of an LED display , three LED status indicator lights and three touchpad buttons. The LED display shows the refrigerator temperature set point and is calibrated in degrees Fahrenheit.
26 Design ■ Features ■ Performance LED Status Meaning 1 Solid Refrigerator T emperature displayed Flashing Not Applicable 2 Solid Service Menu – wait 10 seconds and it will exit automatically Flashing Open thermistor – Refer to Thermistors.
Check Lights on Control Board The lights on the control board indicate power to the labeled component. The exception is the “REF VA L VE” (refrigeration valve). When this light is off, the refrigeration bypass valve is powered. 1. PWR 5. HOT GAS 2.
28 Design ■ Features ■ Performance Compressor COMP To ener gize the compressor touch the previously disconnected pink lead back to the board. Y ou should hear the compressor start up and the green COMP light will illuminate. If it does not start check voltage at the compressor and at the output from the board.
REFRIGERA TION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator W attage Condition Pressure Line Discharge T ube Normal Normal Slightly below V ery hot V ery hot.
30 Design ■ Features ■ Performance ICE THICKNESS ADJUSTMENT Y our U-Line Clear Ice Maker uses advanced technology to make ice that is crystal clear . This technology cascades a flow of water over a chilled ice mold that is mounted vertically so no water sits in it.
31 Design ■ Features ■ Performance 1. Disconnect power to the unit. Access Cover 2. Remove the screws securing the front access panel. Ice Thickness Adjustment Dial CLRCO031 0 1 2 -2 3 4 5 -5 -4 -.
32 Design ■ Features ■ Performance 3. Locate the ice cube thickness adjustment dial on the control board. T urn the dial clockwise (+ number) to thicken or counterclockwise (- number) to thin the ice bridge. Ice Cube Mold 4. Reinstall front access cover .
33 Design ■ Features ■ Performance SER VICING TROUBLESHOOTING 1 Not refrigerating (compressor and fan are operating) CAUSE REMEDY a. Little or no frost pattern on evaporator a. Check for sealed system leak or restriction 2 Not refrigerating (compressor not operating, fan operating) CAUSE REMEDY a.
34 Design ■ Features ■ Performance SER VICING 8 No ice production CAUSE REMEDY a. No water supplied to unit a. Check that water is connected and turned on b. Stand pipe not inserted in water trough b. Insert stand pipe securely into water trough 9 Low ice production CAUSE REMEDY a.
35 Design ■ Features ■ Performance SER VICING CLR2075 W iring Diagram CLRCO028 -1 -2 -3 -4 -5 5 4 3 2 1 0 WHITE GREEN RED BLACK RED BLACK WHITE GREEN THIS SIDE TO DISPLAY 10 9 8 7 6 5 4 3 2 1 Ther.
36 Design ■ Features ■ Performance SER VICING PA R TS LISTING How to Order Replacement Parts 1. Locate the illustration(s) for the model you are servicing. 2. Refer to the area where the desired part would be installed, locate the part and note the item number assigned to it.
37 Design ■ Features ■ Performance CLRCO2075 MODEL NOTES.
MODEL CLRCO2075 (1 OF 3) CLRCO032 2 3 4 5 6 10 11 12 13 14 15 16 17 18 22 23 24 25 26 27 7 1 8 21 20 19 9 38 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS.
39 Design ■ Features ■ Performance MODEL CLRCO2075 (1 OF 3) CLRCO2075 MODEL P ARTS Parts Not Shown Item Description White Black Stainless Steel 1 Door Assembly 80-17019-02 80-17019-01 See Parts No.
40 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS MODEL CLRCO2075 (2 OF 3) CLRCO033 16 1 15 17 18 19 20 21 22 23 2 3 4 5 6 7 8 9 10 11 12 13 14.
MODEL CLRCO2075 (2 OF 3) 41 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS Item Description White Black Stainless Steel 1 Cover - Front 12070-01 12070-01 12070-01 2 Evaporator Assembly 227.
42 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS MODEL CLRCO2075 (3 OF 3) CLRCO034 5 4 9 10 13 2 1 6 7 8 3 14 11 12.
43 Design ■ Features ■ Performance CLRCO2075 MODEL P ARTS Item Description White Black Stainless Steel 1 Heat Exchanger Assembly 72006-S 72006-S 72006-S 2 Back Panel 1 1969-02 1 1969-02 1 1969-02 .
44 Design ■ Features ■ Performance NOTES.
45 Design ■ Features ■ Performance NOTES.
46 Design ■ Features ■ Performance NOTES.
47 F AX P ARTS ORDER FORM F AX # 414-354-7905 Account# ____________________________________ Bill to: ______________________________________ ____________________________________________ _______________.
P .O. Box 245040 Milwaukee, WI 53224-9540 Phone 414.354.0300 F AX 414.354.7905 Printed in U.S .A. – A ugust 2003 ULIN 9332 P/N 30018.
Ein wichtiger Punkt beim Kauf des Geräts U-Line CLRCO2075 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie U-Line CLRCO2075 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für U-Line CLRCO2075 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von U-Line CLRCO2075 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über U-Line CLRCO2075 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon U-Line CLRCO2075 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von U-Line CLRCO2075 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit U-Line CLRCO2075. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei U-Line CLRCO2075 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.