Benutzeranleitung / Produktwartung SP3015EEAZ des Produzenten TriStar
Zur Seite of 15
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS P/N: IS32 00 Rev. D __________________________________________________________________________________________ OWNER’S M ANUAL INSTALLATION, OPERATION, & PART S * 50HZ Mode ls are not UL Liste d.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ____________________ _____________________________Page 2 of 15 IMPORTANT SAFETY I NSTRUCTIONS Before installing or se rvicing this electrical equipment, turn power su pply OFF.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series __________ _____ ________________________________Page 3 of 15 WARNING – It is required that license d electricians do all electrical wiring. Risk of Electric Shock.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series __________ _____ ______________________________ Page 4 of 15 WARNING – Hazardous Pressure. Pool and s pa water ci rculation syst ems operate un der hazardous pressure during s tart-up, normal operation, and af ter pump shut- off.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series__________ _____ ______________________________ Page 5 of 15 Produc t Specific ations Install ation Instruct ions WARNING – This product should be ins talled and serviced on ly by a qu alified profess ional.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series __________ _____ _______________________________ Page 6 of 15 Pump Mounting (cont’d.) WARNING – Hazardous Pressure. Pum ps, filters, and other equipment/ components of a swimming pool f iltration system operate under press ure.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series __________ _____ _______________________________ Page 7 of 15 Electrical ( cont’d.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ ______________________________Page 8 of 15 WARNING – All suction and discharge valves MU S T be OPE N , as well as filter air relief valve (if av ailable) on filter, when starting the circulating pum p system.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ ______________________________Page 9 of 15 Storage/Winterizat ion WARNING – Separation Hazard.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ ______________________________ Page 10 of 15 Removing the Impeller (See Parts D iagram on page 11 of thi s manual for pum p component locations.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ _____________________________Page 11 of 15 Replacement Parts Parts Diagram Parts Listing Ref. No. Part No. Description Ctn. Qty. 1 SPX 3200UNKIT Union Connector Kit (Inc l udes Union Nut, Union Connec tor, Union Gasket - 2 ea.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ _________________________ Page 12 of 15 Parts Listing (cont’d.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ____________________P age 13 of 15 Trouble shootin g Motor Will NOT St art – Check For: Make sure the terminal board connections agree with the wiring diagram on motor data plate label.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series ___________________ ____________________________ Page 14 of 15 Low Flow – Generally, Check For: (cont’d.) 2. Undersi zed pool piping . Solution: Correct piping size.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar ™ Pump Series Page 15 of 15 ▲ Retain this Warranty Certificate ( upper portio n) in a safe a nd convenient l ocation for y our records. ▼ DETACH HERE: Fill ou t bottom portion completely and mail within 10 days of p urchase/installa tion, or register online at WWW .
Ein wichtiger Punkt beim Kauf des Geräts TriStar SP3015EEAZ (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie TriStar SP3015EEAZ noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für TriStar SP3015EEAZ - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von TriStar SP3015EEAZ reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über TriStar SP3015EEAZ erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon TriStar SP3015EEAZ besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von TriStar SP3015EEAZ verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit TriStar SP3015EEAZ. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei TriStar SP3015EEAZ gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.