Benutzeranleitung / Produktwartung HE Plus 2000 des Produzenten Trion
Zur Seite of 14
ELECTRONIC AIR CLEANER LIMITED THREE-YEAR W ARRANTY This limited warranty covers T rion Residential T ype Electronic Air Cleaners, excluding ductwork, wiring and installation. T rion warrants that all new T rion Electronic Residential Air Cleaners are free from defects in material and workmanship under normal, noncommercial use and service.
Power T ray Assembly 120/50-60/1 Power T ray Assembly 240/50-60/1 High Frequency Power Supply* Electronic Air Flow Sensor* On/Off switch* Interlock Switch* Cabinet Assembly Pre-Filter (2 req.) Cell, Ionizing-Collecting (2 req.) Ionizing Wire Assembly Front Panel Assembly Contact Board Assembly (2 req.
10. If no voltage is present, remove the second cell. Install cell number one and measure voltage as described in step #7. If voltage is present, the second cell, which is now out of the cabinet, is shorted. Refer to COMMON TROUBLESHOOTING TECHNIQUES (pg.
SECONDAR Y CIRCUIT POWER SUPPL Y If the Red CELL ENERGIZED light remains out with the Ionizing-Collecting Cells removed from the cabinet, the power supply is defective. Specific problems in the Power T ray Assembly can be isolated by using a Multimeter and High V oltage Probe to check the output voltages.
SECONDAR Y CIRCUIT IONIZING-COLLECTING CELL The cells are electrically energized through a contact terminal located at the top center of each cell. The ionizing wires and alternating collector plates are electrically charged while the interleaving plates are grounded.
PRIMAR Y CIRCUIT WITH HV AC SYSTEM BLOWER OPERA TING • If there is no supply line voltage at the transformer input connections, correct the fault at the dedicated power source or HV AC system power source.
TROUBLESHOOTING W ARNING: • These procedures must be performed by a qualified HV AC technician or electrician. • Risk of personal injury or death could occur by attempting to troubleshoot or r epair this unit by untrained persons. • Exercise the usual pr ecautions when working with high voltage.
SYSTEM CHECKOUT W ARNING: The following procedur es must be conducted by a qualified HV AC contractor or repair person ONL Y . These procedur es will expose hazardous electrically energized charged components. Disconnect power between checks and proceed car efully .
ELECTRICAL INST ALLA TION CAUTION : If the Electronic Air Cleaner is wir ed directly to the integrated accessory control on the furnace, it is imperative that the ampere rating of the contr ol be sufficient to handle the curr ent requir ed by the air cleaner .
NOTE: The following is a typical installation of the air cleaner on a highboy furnace. Y ou may have to alter the installation to fit your particular application. 1. Locate the cabinet in the cold air return duct such that all of the return air flows through the unit.
INST ALLA TION CAUTION: Only a trained, experienced servicer should install this Electronic Air Cleaner . The Front Panel Assembly , Power T ray Assembly , Ionizing-Collecting Cells and Pre-filters should be r emoved befor e installation. T o remove the Power T ray Assembly , remove the two (2) screws fr om inside the top front of the cabinet.
Installation 15 EAC20002025 EAC14001625 EAC14002020 Unit Dimensions 10 For Qualified HV AC Installer Only TYPICAL MOUNTING POSITIONS (Air cleaner shown shaded in illustrations) Horizontal Furnace – Mounted vertically in return duct as close to the furnace as possible.
LOCA TION SELECTION Remember to select a location that is readily accessible for periodic inspection and cleaning of the the Pre- filters and Ionizing-Collecting Cells. Allow a minimum of 24” clearance in front and 12” clearance above the air cleaner for component removal and service space.
Atomizing Humidifiers If an atomizing humidifier is mounted upstream of the air cleaner: 1. Mount the humidifier as far upstream in the ductwork as possible. A distance of at least 10 feet is recommended to reduce the possibility of excessive arcing as water droplets pass through the Electronic Air Cleaner .
Ein wichtiger Punkt beim Kauf des Geräts Trion HE Plus 2000 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Trion HE Plus 2000 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Trion HE Plus 2000 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Trion HE Plus 2000 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Trion HE Plus 2000 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Trion HE Plus 2000 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Trion HE Plus 2000 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Trion HE Plus 2000. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Trion HE Plus 2000 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.