Modular Multi-position Air Handler s GA T2A0B42S31SA GA T2A0C48S41SA GA T2A0C60S51SA PUB. NO . 22-1857-03.
2 Pub . No. 22-1857-03 Featur es and Benefits © 2012 T rane • Unique Cabinet Design - Double Wall F oamed and F or med Cabinet System - W ater Proof Cabinet Design - R-4.
Pub . No . 22-1857-03 3 Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benets 5 General Data 6 GA T2A0B42S31SA 6 GA T2A0C48S41SA 6 GA T2A0C60S51SA 6 P erf.
4 Pub . No. 22-1857-03 Optional Equipment Accessory Number Description Fits Cabinet Size BA YEAA C05BK1A Electric Heater , 5kW , Breaker , 24V Control, 1 Ph A to C BA YEAA C05LG1A Electric Heater , 5k.
Pub . No . 22-1857-03 5 Unique Cabinet Design Featur es and Benefits 5 Conduit Connections e Integrated Horizontal Drain P ans 6 T ool-less Door Fastener s w Compact 20.
6 Pub . No. 22-1857-03 General Data 1 These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI ST ANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for perf ormance data. 2 3/4" Male Plastic Pipe (Ref .
Pub . No . 22-1857-03 7 General Data AIRFLO W PERFORMANCE GA T2A0B42S31SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 1646 1495 1358 1522 1298 1138 0.1 1599 1464 1335 1489 1285 1137 0.
8 Pub . No. 22-1857-03 Per for mance Data GA T2A0C48 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GA T2A0C48S41SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 1904 1711 1541 1652 1455 1305 0.
Pub . No . 22-1857-03 9 Per for mance Data GA T2A0C60 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GA T2A0C60S51SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 5 4 † 3 2 1 5 4 † 3 2 1 0 2169 1956 1874 1739 1633 2165 2033 1871 1736 1629 0.
10 Pub . No . 22-1857-03 Per for mance Data WIRING D A T A GA T2A0B42S31SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 2.
Pub . No . 22-1857-03 11 Per for mance Data WIRING D A T A GA T2A0C48S41SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 3.
12 Pub . No . 22-1857-03 Per for mance Data DIST ANCE FROM BELL Y B AND T O SHAFT F A CE OF MO T OR FOR MINIMUM VIBRA TION WHEEL BLO WER HOUSING BELL Y BAND M OTO R A A is determined per char t Wheel .
WIRING DIA GRAM FOR GA T2A0B42 AND GA T2A0C48 AIR HANDLERS.
WIRING DIA GRAM FOR GA T2A0C60 AIR HANDLERS.
Pub . No . 22-1857-03 15 Field Wiring GA T2 AIR HANDLERS WITH SINGLE SPEED COOLING • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat.
16 Pub . No . 22-1857-03 Field Wiring GA T2 AIR HANDLERS WITH SINGLE SPEED HEA T PUMP • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage o.
Pub . No . 22-1857-03 17 GA T2 Conver tibility Multi-position Air Handler Airflow Airflow Airflow Upflow Condensate Drains Refrigerant Connections Horizontal Left* V er tical Upflow* (as shipped) Hori.
18 Pub . No . 22-1857-03 Dimensions GA T2 AIR HANDLER DIMENSIONAL D A T A D H W Model No . H W D GA T2A0B42 55.7 21.3 21.75 GA T2A0C48 56.9 23.5 21.75 GA T2A0C60 61.
Pub . No . 22-1857-03 19 GA T2 OUTLINE DRA WING MODEL NO . A B C D E F H FLO W CONTROL GAS LINE BRAZE GA T2A0B42 55.7 45.5 18.4 21.3 18.4 9.2 24.8 TXV 7/8 GA T2A0C48 56.9 46.7 20.5 23.5 20.5 10.3 24.2 TXV 7/8 GA T2A0C60 61.7 51.5 20.5 23.5 20.5 10.3 27.
T rane 6200 T roup Highway T yler , TX 75707 www .trane .com 03/12 The manuf acturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
Ein wichtiger Punkt beim Kauf des Geräts Trane GAT2A0C48S41SA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Trane GAT2A0C48S41SA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Trane GAT2A0C48S41SA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Trane GAT2A0C48S41SA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Trane GAT2A0C48S41SA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Trane GAT2A0C48S41SA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Trane GAT2A0C48S41SA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Trane GAT2A0C48S41SA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Trane GAT2A0C48S41SA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.