© 2008 Trane Pub. No. 22-1797-03 Product Data 4YCY4024A through 4YCY4060A Single Packaged Convertible Gas/Electric 14 SEER 2 - 5 Ton, 40 - 120 KBTU R-410A 22-1797-03.
2 It's Hard to Stop a Trane. Single Packaged Convertible Gas/Electric System Trane offers a complete family of packaged gas/electric heating and cooling sys- tems, designed to give you the unbeatable combination of energy efficiency and lower operating costs.
3 Contents Optional Equipment Listing 4 General Data 5 Performance Data Cooling 9 Indoor Fan 11 Typical Wiring 15 Optional Equipment 18 Dimensional Data 23 Mechanical Specifications 29.
4 Optional Equipment Listing OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [ ✓ ✓ ✓ ✓ ✓ ] indicates accessories included) Hinged Filter Access Door (4YCY4024-036) 8 ................................................................ BA Y ACCDOR1A[ ] Hinged Filter Access Door (4YCY4042-060) 8 .
5 MODEL RA TED Volts/PH/Hz Performance Cooling BTUH j Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr .) n Sound Power Rating [dB(A)] 8 Performance Heating k Input BTUH - 1st Stage (Natural Gas) p Input BTUH - 2nd Stage (Natural Gas) p AFUE T emp.
6 General Data MODEL RA TED Volts/PH/Hz Performance Cooling BTUH j Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr .) n Sound Power Rating [dB(A)] 8 Performance Heating k Input BTUH - 1st Stage (Natural Gas) p Input BTUH - 2nd Stage (Natural Gas) p AFUE T emp.
7 General Data 1 1 1 1 1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270. 2 2 2 2 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft.
8 General Data MODEL RA TED Volts/PH/Hz Performance Cooling BTUH j Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr .) n Sound Power Rating [dB(A)] 8 Performance Heating k Input BTUH - 1st Stage (Natural Gas) p Input BTUH - 2nd Stage (Natural Gas) p AFUE T emp.
9 Performance Data Cooling 4YCY4036A1/3 A T 1200 NOM CFM (COOLING PERFORMANCE A T INDOOR DRY BULB TEMPERA TURES) OD ID TO T SENS CA P A T ENTERING DB TEMP TO T AL AMB WB CAP 72 75 78 80 KW 85 59 34.5 28.8 32.4 34.5 34.5 2.7 63 36.0 23.4 27.0 30.5 32.9 2.
10 Performance Data Cooling 4YCY4048A1/3 A T 1600 NOM CFM (COOLING PERFORMANCE A T INDOOR DRY BULB TEMPERA TURES) OD ID TO T SENS CA P A T ENTERING DB TEMP TO T AL AMB WB CA P 72 75 78 80 KW 85 59 45.3 38.2 42.9 45.3 45.3 3.6 63 47.2 31.0 35.7 40.5 43.
11 Indoor Blower Performance Indoor Fan Performance 4YCY4024A Down Airflow Horizontal Airflow 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 52 66 89 115 140 164 186 206 229 259 300 CFM 706 716 727 733.
12 Indoor Blower Performance Indoor Fan Performance 4YCY4042A Down Airflow Horizontal Airflow 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 162 173 197 226 256 285 313 343 383 440 525 CFM 1058 1062 10.
13 Indoor Fan Performance 4YCY4060A Down Airflow Horizontal Airflow 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 200 220 250 285 320 354 386 417 449 487 538 CFM 1407 1394 1396 1403 1408 1408 1402 139.
14 Heating Airflow, horizontal or downflow from .2 to .6” wg. Selection Low Stage High Stage 7-OFF 8-OFF A 600 850 7-ON 8-OFF B 625 900 7-OFF 8-ON C 650 925 7-ON 8-ON D 700 975 4YCY4024A1064 Switch .
15 Typical Field Wiring C 757192i2 B G Y W1 W2 R COMMON FA N COMPRESSOR HEA T FIRST ST AGE HEA T SECOND ST AGE 24V UNIT CONTROL BO X GROUND WIRE 3 PH POWER UNIT NO TE 1 1 PH POWER B G Y W1 W2 R COMMON.
16 Typical Wiring.
17 From Dwg. 21D757165 P02 Typical Wiring.
18 Optional Equipment BA YCURB050A Full Perimeter Roof Mounting Curb for *****018-036A 46 3/8 17 7/8 3 3 5/8 19 1/2 2 3/16 19 1/2 14 1 1/2 38 7/8 15 35 7/8 43 3/8 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.
19 Optional Equipment BA YCURB051A Full Perimeter Roof Mounting Curb for *****042-060A 56 1/8 15 7/8 3 10 7/8 19 1/2 4 3/4 19 1/2 14 41 7/8 20 1 1/2 38 7/8 53 1/8 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.
20 Optional Equipment The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings.
21 BA YECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) BA YECON200,201A Horizontal Economizer and Rain Hood Return Duct Roofcurb Relief damper Mist eli.
22 A B C D FULL Y OPEN 2/3 1/3 FULL Y CLOSED BA YDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) BA YOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) Optional Equipment The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only.
23 Dimensional Data 4YCY4024A through 4YCY4036A (1 of 3).
24 Dimensional Data 4YCY4024A through 4YCY4036A (2 of 3).
25 4YCY4024A through 4YCY4036A (3 of 3) Dimensional Data.
26 Dimensional Data 4YCY4042A through 4YCY4060A (1 of 3).
27 Dimensional Data 4YCY4042A through 4YCY4060A (2 of 3).
28 4YCY4042A through 4YCY4060A (3 of 3) Dimensional Data.
29 Mechanical Specifications General All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be designed to operate at outdoor ambient temperatures as high as 1 15°F. Cooling capacities shall be rated in accordance with A.
Ein wichtiger Punkt beim Kauf des Geräts Trane 4YCY4024A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Trane 4YCY4024A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Trane 4YCY4024A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Trane 4YCY4024A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Trane 4YCY4024A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Trane 4YCY4024A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Trane 4YCY4024A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Trane 4YCY4024A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Trane 4YCY4024A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.